Investigation of Short Chain PFAS Degradation Efficiency Using Free-Standing Boron Doped Diamond Electrodes at High Current Density in a Flow Cell.

ACS electrochemistry Pub Date : 2025-08-12 eCollection Date: 2025-10-02 DOI:10.1021/acselectrochem.5c00121
Marius Amerio-Cox, Joshua J Tully, Fengping Tang, Anna Dettlaff, Julie V Macpherson, Timothy Mollart, Tim Sidnell, Simone Mathias, Patrick Sears, Madeleine J Bussemaker
{"title":"Investigation of Short Chain PFAS Degradation Efficiency Using Free-Standing Boron Doped Diamond Electrodes at High Current Density in a Flow Cell.","authors":"Marius Amerio-Cox, Joshua J Tully, Fengping Tang, Anna Dettlaff, Julie V Macpherson, Timothy Mollart, Tim Sidnell, Simone Mathias, Patrick Sears, Madeleine J Bussemaker","doi":"10.1021/acselectrochem.5c00121","DOIUrl":null,"url":null,"abstract":"<p><p>Short chain PFAS is known to be more challenging to destructively remove than its longer chain counterparts. Electrochemical oxidation at boron doped diamond (BDD) electrodes is one promising way forward. The majority of investigations are carried out using thin film, high grain density BDD electrodes (attached to the growth substrate) at low current densities of <50 mA cm<sup>-2</sup>. In this work, the impact of high current density on short chain (C<sub>4</sub>), perfluorobutanoic acid (PFBA), and perfluorobutanesulfonic acid (PFBS) removal rates and defluorination efficiency is investigated in a recirculating flow system. These studies are carried out using free-standing BDD electrodes, which are grown thick enough so that the BDD can be removed from the non-diamond growth substrate and thus contain a much lower grain density compared to thin-film BDD. The cell utilizes four BDD electrodes, where only the two outer electrodes are directly connected to a potential supply, the two inner electrodes are electrically unconnected, and driven in a bipolar arrangement. Solutions contain saturated potassium sulfate as the electrolyte. A current density of ≥390 mA cm<sup>-2</sup> (after correcting for surface roughness) is employed for times up to 9 h. PFBS/PFBA concentrations in the range range ∼1-60 mg L<sup>-1</sup> are investigated. Importantly when comparing rate constant data to literature for similar concentrations (after normalization of the rate constants to treatment volume/anode area), the values suggest removal rates approximately an order of magnitude higher than those at lower current density (in stirred solutions). Defluorination efficiency is also found to be higher with (close to) complete defluorination indicated at higher concentrations/longer times for short chain PFAS. Microscopy analysis of the free-standing electrodes after deployment for >90 h of advanced oxidation reveals no obvious signs of corrosion. This likely reflects both the reduced grain boundary density and lower sp<sup>2</sup> carbon content in thick free-standing BDD. The data highlight the potential for this electrode material in long term electrochemical treatment of short chain PFAS solutions in recirculating flow systems.</p>","PeriodicalId":520400,"journal":{"name":"ACS electrochemistry","volume":"1 10","pages":"2014-2023"},"PeriodicalIF":0.0000,"publicationDate":"2025-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12498407/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS electrochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acselectrochem.5c00121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/2 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Short chain PFAS is known to be more challenging to destructively remove than its longer chain counterparts. Electrochemical oxidation at boron doped diamond (BDD) electrodes is one promising way forward. The majority of investigations are carried out using thin film, high grain density BDD electrodes (attached to the growth substrate) at low current densities of <50 mA cm-2. In this work, the impact of high current density on short chain (C4), perfluorobutanoic acid (PFBA), and perfluorobutanesulfonic acid (PFBS) removal rates and defluorination efficiency is investigated in a recirculating flow system. These studies are carried out using free-standing BDD electrodes, which are grown thick enough so that the BDD can be removed from the non-diamond growth substrate and thus contain a much lower grain density compared to thin-film BDD. The cell utilizes four BDD electrodes, where only the two outer electrodes are directly connected to a potential supply, the two inner electrodes are electrically unconnected, and driven in a bipolar arrangement. Solutions contain saturated potassium sulfate as the electrolyte. A current density of ≥390 mA cm-2 (after correcting for surface roughness) is employed for times up to 9 h. PFBS/PFBA concentrations in the range range ∼1-60 mg L-1 are investigated. Importantly when comparing rate constant data to literature for similar concentrations (after normalization of the rate constants to treatment volume/anode area), the values suggest removal rates approximately an order of magnitude higher than those at lower current density (in stirred solutions). Defluorination efficiency is also found to be higher with (close to) complete defluorination indicated at higher concentrations/longer times for short chain PFAS. Microscopy analysis of the free-standing electrodes after deployment for >90 h of advanced oxidation reveals no obvious signs of corrosion. This likely reflects both the reduced grain boundary density and lower sp2 carbon content in thick free-standing BDD. The data highlight the potential for this electrode material in long term electrochemical treatment of short chain PFAS solutions in recirculating flow systems.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
流动电池中高电流密度独立掺杂硼金刚石电极对短链PFAS降解效率的研究。
众所周知,短链PFAS比长链PFAS更难被清除。硼掺杂金刚石(BDD)电极上的电化学氧化是一种很有前途的方法。大多数研究都是在低电流密度-2的情况下使用薄膜、高晶粒密度的BDD电极(附着在生长衬底上)进行的。在循环系统中,研究了高电流密度对短链(C4)、全氟丁酸(PFBA)和全氟丁烷磺酸(PFBS)去除率和除氟效率的影响。这些研究是使用独立的BDD电极进行的,这些电极生长得足够厚,使得BDD可以从非金刚石生长衬底上移除,因此与薄膜BDD相比,BDD的颗粒密度要低得多。电池采用四个BDD电极,其中只有两个外部电极直接连接到电位电源,两个内部电极不连接,并以双极排列驱动。溶液中含有饱和硫酸钾作为电解质。电流密度≥390 mA cm-2(校正表面粗糙度后)的使用时间长达9小时。PFBS/PFBA浓度范围为1-60 mg L-1。重要的是,当将相似浓度下的速率常数数据与文献进行比较时(在速率常数与处理体积/阳极面积归一化之后),这些值表明去除率大约比低电流密度下(在搅拌溶液中)的去除率高一个数量级。对于短链PFAS,在更高的浓度/更长的时间下,除氟效率也更高,(接近)完全除氟。在深度氧化bbb90小时后,对独立电极进行显微镜分析,发现没有明显的腐蚀迹象。这可能反映了厚的独立BDD降低了晶界密度和降低了sp2碳含量。这些数据突出了这种电极材料在循环系统中短链PFAS溶液的长期电化学处理中的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
FRET-Enhanced Optical Imaging of Nanoparticle Collision on a Gold Ultramicroelectrode. C(sp3)-F Adsorption Implicated for Reductive Activation at Ag Electrodes. Size-Dependent Oxidation of Copper Nanostructured Electrocatalysts Produced by Spark Ablation. Oxidative Stability and Redox Coupling in 3,4,3-LI(1,2-HOPO) f‑Element Complexes under Acidic Conditions. Mechanistic Insights into the Suppression of Proton Intercalation and the Hydrogen Evolution Reaction through Phosphorus Doping in Tungsten Oxide.
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1