Characterization of 2′′×2′′ CeBr3 scintillator detectors

IF 1.5 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment Pub Date : 2026-06-01 Epub Date: 2026-02-03 DOI:10.1016/j.nima.2026.171357
S. Manna , T.K. Rana , Deepak Pandit , Sudip Ghosh , Saswata Roy , S. Kundu , K. Banerjee , P. Pant , R. Shil , R. Pandey
{"title":"Characterization of 2′′×2′′ CeBr3 scintillator detectors","authors":"S. Manna ,&nbsp;T.K. Rana ,&nbsp;Deepak Pandit ,&nbsp;Sudip Ghosh ,&nbsp;Saswata Roy ,&nbsp;S. Kundu ,&nbsp;K. Banerjee ,&nbsp;P. Pant ,&nbsp;R. Shil ,&nbsp;R. Pandey","doi":"10.1016/j.nima.2026.171357","DOIUrl":null,"url":null,"abstract":"<div><div>Characterization of a cylindrical CeBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span> detector, 2<span><math><mrow><msup><mrow></mrow><mrow><mo>′</mo><mo>′</mo></mrow></msup><mo>×</mo><msup><mrow><mn>2</mn></mrow><mrow><mo>′</mo><mo>′</mo></mrow></msup></mrow></math></span> crystal coupled to a photomultiplier tube (PMT) Hamamatsu R13089-100, has been carried out using various <span><math><mi>γ</mi></math></span>-ray sources with energies ranging from 81 to 4440 keV. The measured energy response of the detector has been compared with <span>Geant4</span> simulation. The time response of the crystal, essential for several nuclear physics applications, has also been studied, yielding a time resolution of 260(1) ps for a single detector for 1173–1333 keV <span><math><mi>γ</mi></math></span>-ray cascade. Furthermore, the intrinsic efficiency of the detector has been determined and compared with simulation results—reported for the first time for this crystal size.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1086 ","pages":"Article 171357"},"PeriodicalIF":1.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900226000835","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Characterization of a cylindrical CeBr3 detector, 2′′×2′′ crystal coupled to a photomultiplier tube (PMT) Hamamatsu R13089-100, has been carried out using various γ-ray sources with energies ranging from 81 to 4440 keV. The measured energy response of the detector has been compared with Geant4 simulation. The time response of the crystal, essential for several nuclear physics applications, has also been studied, yielding a time resolution of 260(1) ps for a single detector for 1173–1333 keV γ-ray cascade. Furthermore, the intrinsic efficiency of the detector has been determined and compared with simulation results—reported for the first time for this crystal size.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
2个“×2”CeBr3闪烁体探测器的表征
利用能量为81 ~ 4440 keV的γ射线源,研究了一个圆柱形CeBr3探测器,2“×2”晶体耦合到一个光电倍增管(PMT) Hamamatsu R13089-100。并将探测器的实测能量响应与Geant4仿真结果进行了比较。晶体的时间响应,对几个核物理应用至关重要,也进行了研究,为1173-1333 keV γ射线级联的单个探测器提供了260(1)ps的时间分辨率。此外,还确定了探测器的固有效率,并将其与模拟结果进行了比较,这是该晶体尺寸首次报道的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
期刊最新文献
Detection of light-ions produced in fast neutron induced nuclear reactions The High-Energy Light Isotope eXperiment (HELIX) instrument High-accuracy ultrasonic positioning of calibration sources in the Jiangmen Underground Neutrino Observatory Compact readout electronics based on resistor network for SiPM-Coupled scintillator arrays in MeV gamma-ray detection PSEC6: An 8-channel 40 GSa/s waveform sampling ASIC in TSMC 65 nm with 10.24 GHz PLL
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1