Development of a micro separation and analysis system for uranyl ions composed of microplug extraction and liquid scintillation detection

IF 2 4区 化学 Q3 CHEMISTRY, ANALYTICAL Analytical Sciences Pub Date : 2026-04-06 DOI:10.1007/s44211-026-00887-0
Xinyi Qian, Naoki Shitara, Naokazu Idota, Takehiko Tsukahara
{"title":"Development of a micro separation and analysis system for uranyl ions composed of microplug extraction and liquid scintillation detection","authors":"Xinyi Qian,&nbsp;Naoki Shitara,&nbsp;Naokazu Idota,&nbsp;Takehiko Tsukahara","doi":"10.1007/s44211-026-00887-0","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The efficient separation and analysis of alpha-emitting radionuclides, which will reduce environmental and radiation workers’ workloads, is of growing importance in the conducting of safe and long-term nuclear decommissioning and environmental assessments. This study developed a novel analytical system comprising micro-extraction and liquid scintillation counting (LSC), capable of rapidly and simply analyzing alpha nuclides in small amounts of samples. Bulk extractions and micro-extractions of UO<sub>2</sub><sup>2+</sup> were performed using two types of extractive liquid scintillators containing bis(2-ethylhexyl) phosphate (HDEHP) and <i>N</i>,<i>N</i>,<i>N</i>′,<i>N</i>′-tetra-octyldiglycolamide (TODGA) ligands. The UO<sub>2</sub><sup>2+</sup> extraction rates were evaluated through inductively coupled plasma-optical emission spectrometry (ICP-OES) and LSC measurements. When measuring LSC spectra of the bulk-extracted organic scintillator phases, peaks assigned those of <sup>238</sup>U and <sup>234</sup>U isotopes were clearly observed. The peak intensities and counting rates increased linearly with increasing UO<sub>2</sub><sup>2+</sup> concentrations, confirming that the UO<sub>2</sub><sup>2+</sup> extraction rates determined from LSC measurements agreed well with those from ICP-OES. From the LSC spectra and counting rates of micro-extracted samples, it was confirmed that the HDEHP-type extractive scintillator achieved 100% extraction of UO<sub>2</sub><sup>2+</sup> within 20 s in the lower HNO<sub>3</sub> concentration ranges, which was more than 90 times faster than bulk extraction (30 min), and that quantitative analysis of uranium using LSC was feasible up to 3 M HNO<sub>3</sub>. The results demonstrate that the microfluidic-LSC approach has significant potential as an advanced separation−analysis method. It enables direct measurements of alpha-emitting radionuclides in organic phases without additional operations such as pretreatment and back-extraction.</p>\n <span>AbstractSection</span>\n Graphical abstract\n <div><figure><div><div><picture><source><img></source></picture></div></div></figure></div>\n \n </div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":"42 7","pages":"645 - 652"},"PeriodicalIF":2.0000,"publicationDate":"2026-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-026-00887-0","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The efficient separation and analysis of alpha-emitting radionuclides, which will reduce environmental and radiation workers’ workloads, is of growing importance in the conducting of safe and long-term nuclear decommissioning and environmental assessments. This study developed a novel analytical system comprising micro-extraction and liquid scintillation counting (LSC), capable of rapidly and simply analyzing alpha nuclides in small amounts of samples. Bulk extractions and micro-extractions of UO22+ were performed using two types of extractive liquid scintillators containing bis(2-ethylhexyl) phosphate (HDEHP) and N,N,N′,N′-tetra-octyldiglycolamide (TODGA) ligands. The UO22+ extraction rates were evaluated through inductively coupled plasma-optical emission spectrometry (ICP-OES) and LSC measurements. When measuring LSC spectra of the bulk-extracted organic scintillator phases, peaks assigned those of 238U and 234U isotopes were clearly observed. The peak intensities and counting rates increased linearly with increasing UO22+ concentrations, confirming that the UO22+ extraction rates determined from LSC measurements agreed well with those from ICP-OES. From the LSC spectra and counting rates of micro-extracted samples, it was confirmed that the HDEHP-type extractive scintillator achieved 100% extraction of UO22+ within 20 s in the lower HNO3 concentration ranges, which was more than 90 times faster than bulk extraction (30 min), and that quantitative analysis of uranium using LSC was feasible up to 3 M HNO3. The results demonstrate that the microfluidic-LSC approach has significant potential as an advanced separation−analysis method. It enables direct measurements of alpha-emitting radionuclides in organic phases without additional operations such as pretreatment and back-extraction.

AbstractSection Graphical abstract
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
由微塞萃取和液体闪烁检测组成的铀酰离子微分离分析系统的研制。
有效地分离和分析释放α的放射性核素将减少环境和辐射工作人员的工作量,这在进行安全和长期的核退役和环境评估方面日益重要。本研究开发了一种由微萃取和液体闪烁计数(LSC)组成的新型分析系统,能够快速、简单地分析少量样品中的α核素。采用含有磷酸二乙己基酯(HDEHP)和N,N,N ',N ' -四辛基二醇酰胺(TODGA)配体的两种萃取液闪烁体对UO22+进行了大量萃取和微量萃取。通过电感耦合等离子体光学发射光谱(ICP-OES)和LSC测量来评估UO22+的提取率。当测量大量提取的有机闪烁体相的LSC光谱时,可以清楚地观察到238U和234U同位素的峰。峰值强度和计数率随UO22+浓度的增加而线性增加,证实LSC测定的UO22+提取率与ICP-OES测定的结果吻合较好。从微量提取样品的LSC光谱和计数率可以看出,在低HNO3浓度范围内,hdehp型萃取闪烁体在20 s内实现了UO22+的100%萃取,比整体萃取(30 min)快90倍以上,在3 M HNO3浓度范围内,LSC对铀的定量分析是可行的。结果表明,微流体- lsc方法作为一种先进的分离分析方法具有很大的潜力。它能够在有机相中直接测量α发射放射性核素,而无需额外的预处理和反萃取等操作。摘要部分图形摘要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Sciences
Analytical Sciences 化学-分析化学
CiteScore
2.90
自引率
18.80%
发文量
232
审稿时长
1 months
期刊介绍: Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods. This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.
期刊最新文献
Application of cellulose sponge modified by polypyrrole for thin film microextraction of polycyclic aromatic hydrocarbons. Development of a rotating microfluidic device for efficient solid-phase extraction in food analysis. A correlation-based model-free method for tracking structural changes in in situ X-ray diffraction datasets. Energy deposition rhythm for optimizing high pulse repetition frequency LIBS signals under scan speed-laser frequency interaction. Analysis of acrylamide in food additives via Michael addition derivatization and liquid chromatography-tandem mass spectrometry.
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1