Corneal sensitivity recovery after phacoemulsification: quantitative esthesiometric analysis.

IF 1 4区 医学 Q3 OPHTHALMOLOGY Arquivos brasileiros de oftalmologia Pub Date : 2026-05-25 eCollection Date: 2026-01-01 DOI:10.5935/0004-2749.2025-0312
Isabella Passarelli Giabardo Marques, Christiana Velloso Rebello Hilgert, Caio Henrique Peres Oliani, Juliana Carolina Contrera, Marcello Novoa Colombo-Barboza, Guilherme Novoa Colombo-Barboza, Bernardo Kaplan Moscovici
{"title":"Corneal sensitivity recovery after phacoemulsification: quantitative esthesiometric analysis.","authors":"Isabella Passarelli Giabardo Marques, Christiana Velloso Rebello Hilgert, Caio Henrique Peres Oliani, Juliana Carolina Contrera, Marcello Novoa Colombo-Barboza, Guilherme Novoa Colombo-Barboza, Bernardo Kaplan Moscovici","doi":"10.5935/0004-2749.2025-0312","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry.</p><p><strong>Methods: </strong>This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification with intraocular lens implantation. Central corneal sensitivity was measured using a Cochet-Bonnet® esthesiometer preoperatively and at 30 and 90 days postoperatively. Repeated-measures data were analyzed using Friedman and Wilcoxon signed-rank tests (p<0.05). Inter-eye differences were assessed with a paired Wilcoxon test. Individual changes from baseline (∆30, ∆90) were calculated, and 90-day recovery was categorized according to thresholds aligned with the 5-mm device resolution. Spearman correlation was used to explore associations between age and ∆90.</p><p><strong>Results: </strong>Corneal sensitivity decreased after surgery. In right eyes, mean sensitivity declined from 41.14 ± 7.77 mm at baseline to 36.82 ± 9.03 mm at 30 days and partially recovered to 38.64 ± 7.73 mm at 90 days. In left eyes, sensitivity decreased from 44.11 ± 6.29 mm to 37.39 ± 9.05 mm at 30 days and recovered to 41.82 ± 7.63 mm at 90 days. Left eyes showed higher sensitivity than right eyes at baseline (p=0.023) and at 90 days (p=0.018). At 90 days, complete or near-complete recovery (within ± 5 mm of baseline) occurred in 73.2% of right eyes and 78.0% of left eyes, while improvement above baseline (≥ +5 mm) occurred in 7.3% and 4.9%, respectively. Age showed weak, nonsignificant correlations with ∆90 (p=-0.14 to -0.19; p>0.2).</p><p><strong>Conclusion: </strong>Phacoemulsification with a 2.75-mm clear corneal incision leads to a temporary reduction in central corneal sensitivity, with partial recovery by 90 days. Recovery patterns vary among individuals, highlighting the value of postoperative sensitivity monitoring to identify atypical trajectories and guide ocular surface care during visual rehabilitation.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"89 3","pages":"e20250312"},"PeriodicalIF":1.0000,"publicationDate":"2026-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de oftalmologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5935/0004-2749.2025-0312","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry.

Methods: This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification with intraocular lens implantation. Central corneal sensitivity was measured using a Cochet-Bonnet® esthesiometer preoperatively and at 30 and 90 days postoperatively. Repeated-measures data were analyzed using Friedman and Wilcoxon signed-rank tests (p<0.05). Inter-eye differences were assessed with a paired Wilcoxon test. Individual changes from baseline (∆30, ∆90) were calculated, and 90-day recovery was categorized according to thresholds aligned with the 5-mm device resolution. Spearman correlation was used to explore associations between age and ∆90.

Results: Corneal sensitivity decreased after surgery. In right eyes, mean sensitivity declined from 41.14 ± 7.77 mm at baseline to 36.82 ± 9.03 mm at 30 days and partially recovered to 38.64 ± 7.73 mm at 90 days. In left eyes, sensitivity decreased from 44.11 ± 6.29 mm to 37.39 ± 9.05 mm at 30 days and recovered to 41.82 ± 7.63 mm at 90 days. Left eyes showed higher sensitivity than right eyes at baseline (p=0.023) and at 90 days (p=0.018). At 90 days, complete or near-complete recovery (within ± 5 mm of baseline) occurred in 73.2% of right eyes and 78.0% of left eyes, while improvement above baseline (≥ +5 mm) occurred in 7.3% and 4.9%, respectively. Age showed weak, nonsignificant correlations with ∆90 (p=-0.14 to -0.19; p>0.2).

Conclusion: Phacoemulsification with a 2.75-mm clear corneal incision leads to a temporary reduction in central corneal sensitivity, with partial recovery by 90 days. Recovery patterns vary among individuals, highlighting the value of postoperative sensitivity monitoring to identify atypical trajectories and guide ocular surface care during visual rehabilitation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声乳化术后角膜敏感性恢复:定量美学分析。
目的:定量评估超声乳化术后中央角膜敏感性的变化,并使用标准化的感觉测量法描述90天内的恢复模式。方法:本前瞻性观察研究纳入44例(88眼)行无并发症超声乳化术合并人工晶状体植入术。术前、术后30天和90天采用Cochet-Bonnet®触觉计测量角膜中央敏感度。使用Friedman和Wilcoxon符号秩检验对重复测量数据进行分析(结果:手术后角膜敏感性下降。右眼平均敏感度从基线时的41.14±7.77 mm下降到30 d时的36.82±9.03 mm, 90 d时部分恢复到38.64±7.73 mm。左眼敏感度由44.11±6.29 mm降至37.39±9.05 mm, 90 d恢复至41.82±7.63 mm。左眼在基线时(p=0.023)和90 d时(p=0.018)敏感度高于右眼。90天时,73.2%的右眼和78.0%的左眼完全或接近完全恢复(距基线±5毫米),而高于基线(≥+5毫米)的改善分别为7.3%和4.9%。年龄与∆90表现出弱的、不显著的相关性(p=-0.14 ~ -0.19; p < 0 0.2)。结论:2.75 mm角膜透明切口超声乳化术可使角膜中央敏感性暂时降低,90天部分恢复。恢复模式因人而异,强调术后敏感性监测的价值,以识别非典型的轨迹,并指导视力康复期间的眼表护理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
200
审稿时长
6-12 weeks
期刊介绍: The ABO-ARQUIVOS BRASILEIROS DE OFTALMOLOGIA (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - electronic version), the official bimonthly publication of the Brazilian Council of Ophthalmology (CBO), aims to disseminate scientific studies in Ophthalmology, Visual Science and Health public, by promoting research, improvement and updating of professionals related to the field.
期刊最新文献
Ophthalmologic manifestations in children with autism spectrum disorder. Evaluation of ocular manifestations in children born to mothers infected with SARS-CoV-2 during pregnancy. Bovine pericardium as a patch graft in glaucoma drainage implant surgery: a case series. Can medical regulation keep pace with the speed of technological evolution? Keratoconus false-positive screening rates in eyes with pterygium: tomographic and biomechanical artifacts.
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1