Extending Regression Without Truth to Integrate Ground-Truth Measurements for Evaluating Quantitative Imaging Methods with Patient Data.

Yan Liu, Abhinav K Jha
{"title":"Extending Regression Without Truth to Integrate Ground-Truth Measurements for Evaluating Quantitative Imaging Methods with Patient Data.","authors":"Yan Liu, Abhinav K Jha","doi":"10.1117/12.3088141","DOIUrl":null,"url":null,"abstract":"<p><p>Objective evaluation of quantitative imaging (QI) methods with patient data is often hindered by the lack of gold standards. To address this challenge, a class of regression-without-truth (RWT) techniques have been developed. These techniques assume that the true and measured values are linearly related and estimate the linear-relationship parameters without access to true values. However, reliable estimation of these parameters typically requires many patient samples, which can be expensive and time consuming to obtain, and even impossible in settings such as studies with rare diseases or with new clinical imaging procedures. Thus, there is an important need for strategies to perform evaluation of quantitative imaging methods with a small number of patient samples. In this context, we note that datasets with known ground truth, such as physical phantom studies, could be available. In this manuscript, we propose an approach that integrates information from both patient data without ground truth and known-ground-truth datasets to perform objective evaluation of QI methods. We validated the proposed approach using numerical studies, which showed that the proposed approach yielded improved performance in ranking QI methods compared with RWT technique. The results demonstrate the potential of the proposed approach for evaluating QI methods when patient data are limited and motivate further validation with clinically realistic simulation studies and clinical data.</p>","PeriodicalId":74505,"journal":{"name":"Proceedings of SPIE--the International Society for Optical Engineering","volume":"13928 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13372251/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of SPIE--the International Society for Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3088141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective evaluation of quantitative imaging (QI) methods with patient data is often hindered by the lack of gold standards. To address this challenge, a class of regression-without-truth (RWT) techniques have been developed. These techniques assume that the true and measured values are linearly related and estimate the linear-relationship parameters without access to true values. However, reliable estimation of these parameters typically requires many patient samples, which can be expensive and time consuming to obtain, and even impossible in settings such as studies with rare diseases or with new clinical imaging procedures. Thus, there is an important need for strategies to perform evaluation of quantitative imaging methods with a small number of patient samples. In this context, we note that datasets with known ground truth, such as physical phantom studies, could be available. In this manuscript, we propose an approach that integrates information from both patient data without ground truth and known-ground-truth datasets to perform objective evaluation of QI methods. We validated the proposed approach using numerical studies, which showed that the proposed approach yielded improved performance in ranking QI methods compared with RWT technique. The results demonstrate the potential of the proposed approach for evaluating QI methods when patient data are limited and motivate further validation with clinically realistic simulation studies and clinical data.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
扩展无真回归,整合地面真值测量,以评估定量成像方法与患者数据。
利用患者数据对定量成像(QI)方法进行客观评价常常受到缺乏金标准的阻碍。为了应对这一挑战,已经开发了一类无真回归(RWT)技术。这些技术假设真实值和测量值是线性相关的,并且在不访问真实值的情况下估计线性关系参数。然而,对这些参数的可靠估计通常需要许多患者样本,这可能是昂贵和耗时的,甚至在罕见疾病研究或新的临床成像程序等环境中是不可能的。因此,有一个重要的需要策略来执行评估定量成像方法与少量患者样本。在这种情况下,我们注意到可以使用具有已知基本事实的数据集,例如物理幻影研究。在本文中,我们提出了一种方法,该方法集成了来自无基础真理和已知基础真理数据集的患者数据的信息,以对QI方法进行客观评估。我们使用数值研究验证了所提出的方法,结果表明,与RWT技术相比,所提出的方法在QI排序方法中产生了更高的性能。结果表明,在患者数据有限的情况下,所提出的评估QI方法的方法具有潜力,并激发了临床现实模拟研究和临床数据的进一步验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
期刊最新文献
Random forest-based out-of-distribution detection for robust lung cancer segmentation. Modeling Workflow, Operational, and Financial Implications of AI-Enabled Same-Day Diagnostic Follow-Up for Screening Mammograms. Noise2Noise Diffusion for Thin-Slice Brain CT Denoising without Clean Training Data. Topological data analysis visualization for interpretable assessment of AI contouring quality. Cohort-Aware Agents for Individualized Lung Cancer Risk Prediction Using a Retrieval-Augmented Model Selection Framework.
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1