Investigation of Multi-parameter Synchronous Detection Technology for Radioactive Aerosols in Spent Fuel Dissolution Process.

IF 1.2 4区 医学 Q4 ENVIRONMENTAL SCIENCES Health physics Pub Date : 2026-11-01 Epub Date: 2026-08-05 DOI:10.1097/HP.0000000000002141
Yongzhen Xia, Runjie Di, Yongji Xie, Xin Wang
{"title":"Investigation of Multi-parameter Synchronous Detection Technology for Radioactive Aerosols in Spent Fuel Dissolution Process.","authors":"Yongzhen Xia, Runjie Di, Yongji Xie, Xin Wang","doi":"10.1097/HP.0000000000002141","DOIUrl":null,"url":null,"abstract":"<p><p>Spent-fuel dissolution produces multi-nuclide, high-activity aerosols. Gross α/β CAMs are prone to interference and slow response, limiting timely dose assessment and alarms. We developed an integrated multiparameter synchronous detection system to simultaneously measure activity concentration, spectra, and particle size. The instrument integrates sampling and optical sizing (0.1-10 μm) with a silicon barrier (α), thin-window proportional (β), and 2 × 2 NaI (Tl) (γ) detectors. Signals are digitized (14-bit/100 MS s -1 ) for pulse-shape discrimination and 8,192-channel spectrometry. Performance followed ISO 11929/Currie. Standard sources and mixed-nuclide aerosols were used for calibration, linearity, response, and misclassification tests; stability was assessed over 720 h (50 L min -1 , 60 s integration). Detection efficiencies were 26.3% ( 241 Am α), 42.5% ( 90 Sr/ 90 Y β), and 31.2% ( 137 Cs γ). Minimum detectable activities were 8.5 × 10 -7 Bq cm -3 ( 241 Am), 9.2 × 10 -7 Bq cm -3 ( 239 Pu), and 3.1 × 10 -6 Bq cm -1 ( 90 Sr/ 90 Y). Dynamic tests gave T 90 = 17.5 s and T 95 = 22.3 s; α/β misclassification < 5%; linearity across five orders (R 2 = 0.9987). Compared with a representative CAM, spectral resolving power improved ≈5-fold and response time shortened 10-20 times. Energy and efficiency drift over 720 h were ≤±2% and ≤±3%. Multi-parameter acquisition reduces dose-assessment bias from nuclide misidentification and size assumptions and shortens alarm latency to < 30 s in high-background, multi-nuclide environments, supporting ALARA and process control during spent-fuel dissolution.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":" ","pages":"482-495"},"PeriodicalIF":1.2000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000002141","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Spent-fuel dissolution produces multi-nuclide, high-activity aerosols. Gross α/β CAMs are prone to interference and slow response, limiting timely dose assessment and alarms. We developed an integrated multiparameter synchronous detection system to simultaneously measure activity concentration, spectra, and particle size. The instrument integrates sampling and optical sizing (0.1-10 μm) with a silicon barrier (α), thin-window proportional (β), and 2 × 2 NaI (Tl) (γ) detectors. Signals are digitized (14-bit/100 MS s -1 ) for pulse-shape discrimination and 8,192-channel spectrometry. Performance followed ISO 11929/Currie. Standard sources and mixed-nuclide aerosols were used for calibration, linearity, response, and misclassification tests; stability was assessed over 720 h (50 L min -1 , 60 s integration). Detection efficiencies were 26.3% ( 241 Am α), 42.5% ( 90 Sr/ 90 Y β), and 31.2% ( 137 Cs γ). Minimum detectable activities were 8.5 × 10 -7 Bq cm -3 ( 241 Am), 9.2 × 10 -7 Bq cm -3 ( 239 Pu), and 3.1 × 10 -6 Bq cm -1 ( 90 Sr/ 90 Y). Dynamic tests gave T 90 = 17.5 s and T 95 = 22.3 s; α/β misclassification < 5%; linearity across five orders (R 2 = 0.9987). Compared with a representative CAM, spectral resolving power improved ≈5-fold and response time shortened 10-20 times. Energy and efficiency drift over 720 h were ≤±2% and ≤±3%. Multi-parameter acquisition reduces dose-assessment bias from nuclide misidentification and size assumptions and shortens alarm latency to < 30 s in high-background, multi-nuclide environments, supporting ALARA and process control during spent-fuel dissolution.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
乏燃料溶解过程中放射性气溶胶多参数同步检测技术研究。
废燃料溶解产生多核素、高活性气溶胶。总的α/β cam容易受到干扰,反应缓慢,限制了及时的剂量评估和警报。我们开发了一个集成的多参数同步检测系统,可以同时测量活性浓度、光谱和粒度。该仪器集成了采样和光学尺寸(0.1-10 μm),硅势垒(α),薄窗比例(β)和2 × 2 NaI (Tl) (γ)探测器。信号被数字化(14位/100 MS s-1),用于脉冲形状识别和8192通道光谱分析。性能遵循ISO 11929/Currie标准。使用标准源和混合核素气溶胶进行校准、线性、响应和误分类试验;在720 h (50 L min-1, 60 s积分)内评估稳定性。检测效率分别为26.3% (241Am α)、42.5% (90Sr/90Y β)和31.2% (137Cs γ)。最小检测活性分别为8.5 × 10-7 Bq cm-3 (241Am)、9.2 × 10-7 Bq cm-3 (239Pu)和3.1 × 10-6 Bq cm-1 (90Sr/90Y)。动态试验T90 = 17.5 s, T95 = 22.3 s;α/β错误分类
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Health physics
Health physics 医学-公共卫生、环境卫生与职业卫生
CiteScore
4.20
自引率
0.00%
发文量
324
审稿时长
3-8 weeks
期刊介绍: Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.
期刊最新文献
Determining the Biological Variability of Daily Amount of Feces to Estimate Dose Uncertainties Based on Data from Mayak Plutonium Workers. New Tools for Threshold-linked Radiological Protection. Evaluation of Natural Radionuclides and Associated Health Risk Assessment in Soil and Rock Samples of Northeastern Rajasthan, India. Organ Dose Assessment in Radiological Central Venous Port Procedures: An Experimental Phantom-Based Study. Determination of 222 Rn Exhalation Rates and Health Effect Evaluation of Some Marbles and Granites Used in Van Province, Turkey: An Experimental Study.
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1