Finger-actuated microfluidic device for point-of-care circulating cell-free nucleic acid extraction.

IF 6.3 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS Lab on a Chip Pub Date : 2026-10-13 DOI:10.1039/d6lc00439c
Ghulam Musaddaq, Labibah Ehsan, Yano Yoga, Joshua Castillo, Linda Marriott, Nicholas R Leslie, Deborah Williamson, Thomas Tran, Chuan Kok Lim, Maïwenn Kersaudy-Kerhoas
{"title":"Finger-actuated microfluidic device for point-of-care circulating cell-free nucleic acid extraction.","authors":"Ghulam Musaddaq, Labibah Ehsan, Yano Yoga, Joshua Castillo, Linda Marriott, Nicholas R Leslie, Deborah Williamson, Thomas Tran, Chuan Kok Lim, Maïwenn Kersaudy-Kerhoas","doi":"10.1039/d6lc00439c","DOIUrl":null,"url":null,"abstract":"<p><p>Timely and accurate nucleic acid extraction is a critical bottleneck in point-of-care (POC) molecular diagnostics, particularly for low-abundance cell-free nucleic acids (DNA, RNA, miRNA) in plasma. We present a fully finger-actuated microfluidic device for power-free, pipette-free, nucleic acid extraction. The prototype device integrates finger-actuated valves, pump and blister reagent storage, enabling a complete, intuitive, \"sample-to-eluate\" workflow, including lysis, binding, washing and elution <i>via</i> manual actuation in approximately 35 minutes. The device operation was benchmarked against a commercial magnetic bead-based manual benchtop and an automated robotic workflow. In DNA-spiked aqueous samples (5-20 ng mL<sup>-1</sup>), the device demonstrated recoveries of 84.6%, against 90.7% on the bench. Optimisation of magnetic bead volume identified 50 μL as the threshold for maximal recovery while minimising reagent consumption. Recovery from human pooled plasma samples were found to be on average 18, 62, and 552% higher than that obtained with the control bench extraction on initial sample volumes of 100, 75 and 50 μL, respectively. Coefficient of variation (CV%) for all techniques remained within reported laboratory ranges (20-80%). The device's clinical utility was piloted using patient samples positive for cytomegalovirus (CMV), monkeypox virus (MPXV) or chikungunya (CHIKV). The device achieved successful qPCR amplification for all targets, with viral DNA Cq values within as little as 0.3 cycles of the standard protocol. This instrument-free, manual circulating nucleic acid extraction tool could help bridge the gap between lateral flow based nucleic acid amplification technologies and real-world decentralised diagnostics, offering a scalable solution for infectious disease management in resource-limited settings.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" ","pages":"5401-5411"},"PeriodicalIF":6.3000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13660751/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d6lc00439c","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Timely and accurate nucleic acid extraction is a critical bottleneck in point-of-care (POC) molecular diagnostics, particularly for low-abundance cell-free nucleic acids (DNA, RNA, miRNA) in plasma. We present a fully finger-actuated microfluidic device for power-free, pipette-free, nucleic acid extraction. The prototype device integrates finger-actuated valves, pump and blister reagent storage, enabling a complete, intuitive, "sample-to-eluate" workflow, including lysis, binding, washing and elution via manual actuation in approximately 35 minutes. The device operation was benchmarked against a commercial magnetic bead-based manual benchtop and an automated robotic workflow. In DNA-spiked aqueous samples (5-20 ng mL-1), the device demonstrated recoveries of 84.6%, against 90.7% on the bench. Optimisation of magnetic bead volume identified 50 μL as the threshold for maximal recovery while minimising reagent consumption. Recovery from human pooled plasma samples were found to be on average 18, 62, and 552% higher than that obtained with the control bench extraction on initial sample volumes of 100, 75 and 50 μL, respectively. Coefficient of variation (CV%) for all techniques remained within reported laboratory ranges (20-80%). The device's clinical utility was piloted using patient samples positive for cytomegalovirus (CMV), monkeypox virus (MPXV) or chikungunya (CHIKV). The device achieved successful qPCR amplification for all targets, with viral DNA Cq values within as little as 0.3 cycles of the standard protocol. This instrument-free, manual circulating nucleic acid extraction tool could help bridge the gap between lateral flow based nucleic acid amplification technologies and real-world decentralised diagnostics, offering a scalable solution for infectious disease management in resource-limited settings.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
手指驱动的即时循环无细胞核酸提取微流体装置。
及时和准确的核酸提取是即时护理(POC)分子诊断的关键瓶颈,特别是对于血浆中低丰度的无细胞核酸(DNA, RNA, miRNA)。我们提出了一种完全手指驱动的微流体装置,用于无电源,无移液管,核酸提取。原型设备集成了手指驱动阀、泵和吸泡试剂存储,实现了完整、直观的“样品到洗脱”工作流程,包括裂解、结合、洗涤和洗脱,通过手动驱动,大约35分钟即可完成。该设备的操作基准是基于商用磁珠的手动工作台和自动化机器人工作流程。在加dna的水溶液样品(5-20 ng mL-1)中,该装置的回收率为84.6%,而在实验台上为90.7%。磁珠体积优化确定50 μL为最大回收率阈值,同时使试剂消耗最小。在初始样品体积为100 μL、75 μL和50 μL时,混合血浆样品的回收率分别比对照台萃取平均高18%、62%和552%。所有技术的变异系数(CV%)保持在报告的实验室范围内(20-80%)。使用巨细胞病毒(CMV)、猴痘病毒(MPXV)或基孔肯雅热(CHIKV)阳性的患者样本对该装置的临床应用进行了试点。该装置成功地实现了所有目标的qPCR扩增,病毒DNA Cq值在标准方案的0.3周期内。这种无需仪器的人工循环核酸提取工具可以帮助弥合基于侧流的核酸扩增技术与现实世界的分散诊断之间的差距,为资源有限的环境下的传染病管理提供可扩展的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Engineering a 3D Microfluidic Platform to Model Neuroimmune Interactions in Periodontal Inflammation Low-order lateral transducer modes enabling millimeter-scale acoustofluidics. Three-dimensional imaging flow cytometry: current trends and future perspectives. Cell-laden hydrogel microspheres as functional 3D cellular units. A rapid point-of-care detection system for OVA-specific IgG and IgE utilizing a rotational SlipChip
wanfang
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1