{"title":"Optimal sizing of renewable generation and storage for grid-connected CO<sub>2</sub> electrolysis: a Dutch case study on syngas production for e-SAF.","authors":"Thijmen Wiltink, Andrea Ramírez, Mar Pérez-Fortes","doi":"10.1039/d6gc04304f","DOIUrl":null,"url":null,"abstract":"<p><p>Co-electrolysis of CO<sub>2</sub> (CO<sub>2</sub>E) and water enables the production of syngas for sustainable aviation fuels (SAF) that are compliant with European RFNBO (renewable fuels of non-biological origin) regulations. However, a mismatch exists between the intermittent renewable electricity supply and the continuous operation of the downstream Fischer-Tropsch plants. To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage. Applying this model to a Dutch case study, we explored grid integration with an electrolyzer across future scenarios with global warming potentials (GWPs) ranging between 35 and 370 g CO<sub>2</sub>-eq per kWh. For generation, the preferred renewable mix is onshore wind combined with PV. When grid mix electricity consumption is restricted, the electrolyzer has an optimal capacity factor of 78% but requires a battery of comparable capacity to the electrolyzer and multi-kilotonne syngas storage to ensure continuous output. Crucially, we found that producing RFNBO-compliant syngas for SAF is impossible with the 2025 Dutch grid mix. Even at a reduced grid intensity of 205 g CO<sub>2</sub>-eq per kWh, RFNBO compliance limits grid consumption to just 1% of grid mix electricity per hour. This results in a levelized cost of 2350 EUR<sub>2019</sub> per tonne syngas. Unrestricted grid electricity consumption becomes feasible when emissions drop below 36 g CO<sub>2</sub>-eq per kWh, reducing production costs by 43% (1344 EUR<sub>2019</sub> per tonne syngas). Consequently, we demonstrate that grid composition intensity is a bottleneck for the short-term economic viability and regulatory compliance of CO<sub>2</sub>E-based SAF in the Netherlands.</p>","PeriodicalId":78,"journal":{"name":"Green Chemistry","volume":" ","pages":"14278-14296"},"PeriodicalIF":10.6000,"publicationDate":"2026-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13487491/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Green Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d6gc04304f","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/14 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Co-electrolysis of CO2 (CO2E) and water enables the production of syngas for sustainable aviation fuels (SAF) that are compliant with European RFNBO (renewable fuels of non-biological origin) regulations. However, a mismatch exists between the intermittent renewable electricity supply and the continuous operation of the downstream Fischer-Tropsch plants. To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage. Applying this model to a Dutch case study, we explored grid integration with an electrolyzer across future scenarios with global warming potentials (GWPs) ranging between 35 and 370 g CO2-eq per kWh. For generation, the preferred renewable mix is onshore wind combined with PV. When grid mix electricity consumption is restricted, the electrolyzer has an optimal capacity factor of 78% but requires a battery of comparable capacity to the electrolyzer and multi-kilotonne syngas storage to ensure continuous output. Crucially, we found that producing RFNBO-compliant syngas for SAF is impossible with the 2025 Dutch grid mix. Even at a reduced grid intensity of 205 g CO2-eq per kWh, RFNBO compliance limits grid consumption to just 1% of grid mix electricity per hour. This results in a levelized cost of 2350 EUR2019 per tonne syngas. Unrestricted grid electricity consumption becomes feasible when emissions drop below 36 g CO2-eq per kWh, reducing production costs by 43% (1344 EUR2019 per tonne syngas). Consequently, we demonstrate that grid composition intensity is a bottleneck for the short-term economic viability and regulatory compliance of CO2E-based SAF in the Netherlands.
期刊介绍:
Green Chemistry is a journal that provides a unique forum for the publication of innovative research on the development of alternative green and sustainable technologies. The scope of Green Chemistry is based on the definition proposed by Anastas and Warner (Green Chemistry: Theory and Practice, P T Anastas and J C Warner, Oxford University Press, Oxford, 1998), which defines green chemistry as the utilisation of a set of principles that reduces or eliminates the use or generation of hazardous substances in the design, manufacture and application of chemical products. Green Chemistry aims to reduce the environmental impact of the chemical enterprise by developing a technology base that is inherently non-toxic to living things and the environment. The journal welcomes submissions on all aspects of research relating to this endeavor and publishes original and significant cutting-edge research that is likely to be of wide general appeal. For a work to be published, it must present a significant advance in green chemistry, including a comparison with existing methods and a demonstration of advantages over those methods.