首页 > 最新文献

Clinical ophthalmology最新文献

英文 中文
Preservative-Free versus Benzalkonium Chloride-Preserved Latanoprost Ophthalmic Solution in Patients with Primary Open-Angle Glaucoma or Ocular Hypertension: A Phase 3 US Clinical Trial. 无防腐剂与苯扎氯铵保存的拉坦前列素眼液治疗原发性开角型青光眼或眼高血压患者:一项3期美国临床试验。
IF 2.2 Q3 OPHTHALMOLOGY Pub Date : 2023-09-01 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S414015
Jason Bacharach, Iqbal Ike K Ahmed, Elizabeth D Sharpe, Michael S Korenfeld, Steven Zhang, Christophe Baudouin

Purpose: To evaluate the safety and efficacy of a preservative-free latanoprost 0.005% formulation (T2345) in patients with primary open-angle glaucoma (POAG) or ocular hypertension (OHT) compared to benzalkonium chloride-preserved latanoprost 0.005% (BPL) formulation in the United States (US).

Patients and methods: A prospective, randomized, multicenter, observer-masked, parallel-group study enrolled 335 patients diagnosed with POAG or OHT from 31 US sites who had adequately controlled intraocular pressure (IOP; ≤18 mm Hg) with latanoprost monotherapy. After a ≥72-hour washout period, patients were randomized to T2345 (n=165) or BPL (n=170) groups. Study drugs were dosed once-daily from Day 0 to Day 84 in one or both eyes. The study eye was the eye with lower IOP at baseline. The primary efficacy measure was the between-group comparison of the mean IOP values in the study eye at each time point (8 AM, 10 AM, and 4 PM on Days 15, 42, and 84). Safety measurements included ocular and systemic treatment-emergent adverse events (TEAEs).

Results: Both T2345 and BPL adequately controlled IOP with 95% CIs within 1.5 mm Hg in the study eye at all assessed time points. The percentages of patients with diurnal IOP <18 mm Hg at Day 84 were 73.1% vs 78.7% for the T2345 and BPL groups, respectively. Adverse events were generally mild-to-moderate and primarily ocular. Fewer patients in the T2345 group experienced ocular TEAEs (13.9% vs 22.5%, respectively) and TEAEs with a suspected relationship to the study medication compared with the BPL group (5.5% vs 11.8%, respectively). The most common ocular TEAEs were instillation site pain and conjunctival hyperemia.

Conclusion: In patients with POAG or OHT, both T2345 and BPL maintained IOP at or below clinically meaningful values for the duration of the study. T2345 showed a favorable safety profile, with numerically lower incidences of ocular TEAEs than BPL.

目的:评估不含防腐剂的0.005%拉坦前列素制剂(T2345)治疗原发性开角型青光眼(POAG)或高眼压(OHT)患者的安全性和有效性,与美国苯扎氯铵保存的0.005%(BPL)制剂相比,平行组研究纳入了来自美国31个地区的335名诊断为POAG或OHT的患者,这些患者通过拉坦前列素单药治疗充分控制了眼压(IOP;≤18mm Hg)。在≥72小时的冲洗期后,患者被随机分为T2345(n=165)或BPL(n=170)组。从第0天至第84天,研究药物在一只或两只眼睛中每天给药一次。研究用眼为基线时眼压较低的眼睛。主要疗效指标是研究眼睛在每个时间点(第15、42和84天的上午8点、上午10点和下午4点)的平均IOP值的组间比较。安全性测量包括眼部和全身治疗突发不良事件(TEAE)。结果:T2345和BPL在所有评估时间点都充分控制了研究眼睛的眼压,95%CI在1.5 mm Hg以内。日间眼压患者的百分比结论:在POAG或OHT患者中,T2345和BPL在研究期间均将眼压维持在或低于临床意义值。T2345显示出良好的安全性,眼部TEAE的发生率在数值上低于BPL。
{"title":"Preservative-Free versus Benzalkonium Chloride-Preserved Latanoprost Ophthalmic Solution in Patients with Primary Open-Angle Glaucoma or Ocular Hypertension: A Phase 3 US Clinical Trial.","authors":"Jason Bacharach,&nbsp;Iqbal Ike K Ahmed,&nbsp;Elizabeth D Sharpe,&nbsp;Michael S Korenfeld,&nbsp;Steven Zhang,&nbsp;Christophe Baudouin","doi":"10.2147/OPTH.S414015","DOIUrl":"10.2147/OPTH.S414015","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and efficacy of a preservative-free latanoprost 0.005% formulation (T2345) in patients with primary open-angle glaucoma (POAG) or ocular hypertension (OHT) compared to benzalkonium chloride-preserved latanoprost 0.005% (BPL) formulation in the United States (US).</p><p><strong>Patients and methods: </strong>A prospective, randomized, multicenter, observer-masked, parallel-group study enrolled 335 patients diagnosed with POAG or OHT from 31 US sites who had adequately controlled intraocular pressure (IOP; ≤18 mm Hg) with latanoprost monotherapy. After a ≥72-hour washout period, patients were randomized to T2345 (n=165) or BPL (n=170) groups. Study drugs were dosed once-daily from Day 0 to Day 84 in one or both eyes. The study eye was the eye with lower IOP at baseline. The primary efficacy measure was the between-group comparison of the mean IOP values in the study eye at each time point (8 AM, 10 AM, and 4 PM on Days 15, 42, and 84). Safety measurements included ocular and systemic treatment-emergent adverse events (TEAEs).</p><p><strong>Results: </strong>Both T2345 and BPL adequately controlled IOP with 95% CIs within 1.5 mm Hg in the study eye at all assessed time points. The percentages of patients with diurnal IOP <18 mm Hg at Day 84 were 73.1% vs 78.7% for the T2345 and BPL groups, respectively. Adverse events were generally mild-to-moderate and primarily ocular. Fewer patients in the T2345 group experienced ocular TEAEs (13.9% vs 22.5%, respectively) and TEAEs with a suspected relationship to the study medication compared with the BPL group (5.5% vs 11.8%, respectively). The most common ocular TEAEs were instillation site pain and conjunctival hyperemia.</p><p><strong>Conclusion: </strong>In patients with POAG or OHT, both T2345 and BPL maintained IOP at or below clinically meaningful values for the duration of the study. T2345 showed a favorable safety profile, with numerically lower incidences of ocular TEAEs than BPL.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2575-2588"},"PeriodicalIF":2.2,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/01/95/opth-17-2575.PMC10478989.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10171062","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Current State of Knowledge in Ocular Blood Flow in Glaucoma: A Narrative Review. 青光眼眼血流的知识现状:叙述性综述。
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-08-31 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S426709
Tariq Alasbali

Glaucoma is a multifactorial disease that is dependent on Intra Ocular Pressure (IOP) and associated with risk factors related to reduced ocular blood flow (OBF). In clinical practice, it is instrumental to update and review the considerable evidence of the current imaging technologies utilized in the investigation of OBF involved in both the onset and progression of glaucoma. Bibliographic databases, including PubMed and Google Scholar, were searched for articles on OBF techniques published between 2018 and 2023 using keywords such as "ocular blood flow", "glaucoma", "invasive ocular blood flow measurement", and "non-invasive ocular blood flow measurement". All types of methodologies were considered, except for editorials, letters to the editor, and animal studies. This review provides comprehensive information on the recent state-of-the-art imaging innovations used to monitor and measure the ocular blood flow in glaucoma.

青光眼是一种多因素疾病,取决于眼内压(IOP),并与眼血流(OBF)减少相关的风险因素有关。在临床实践中,更新和回顾当前用于研究青光眼发病和发展过程中眼底血流的成像技术的大量证据非常重要。我们使用 "眼血流"、"青光眼"、"有创眼底血流测量 "和 "无创眼底血流测量 "等关键词,检索了 2018 年至 2023 年间发表的有关 OBF 技术的文章,包括 PubMed 和 Google Scholar 等文献数据库。除社论、致编辑的信和动物研究外,所有类型的方法论都被考虑在内。本综述全面介绍了近期用于监测和测量青光眼眼血流的最先进的成像创新技术。
{"title":"Current State of Knowledge in Ocular Blood Flow in Glaucoma: A Narrative Review.","authors":"Tariq Alasbali","doi":"10.2147/OPTH.S426709","DOIUrl":"10.2147/OPTH.S426709","url":null,"abstract":"<p><p>Glaucoma is a multifactorial disease that is dependent on Intra Ocular Pressure (IOP) and associated with risk factors related to reduced ocular blood flow (OBF). In clinical practice, it is instrumental to update and review the considerable evidence of the current imaging technologies utilized in the investigation of OBF involved in both the onset and progression of glaucoma. Bibliographic databases, including PubMed and Google Scholar, were searched for articles on OBF techniques published between 2018 and 2023 using keywords such as \"ocular blood flow\", \"glaucoma\", \"invasive ocular blood flow measurement\", and \"non-invasive ocular blood flow measurement\". All types of methodologies were considered, except for editorials, letters to the editor, and animal studies. This review provides comprehensive information on the recent state-of-the-art imaging innovations used to monitor and measure the ocular blood flow in glaucoma.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2599-2607"},"PeriodicalIF":1.8,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3b/dd/opth-17-2599.PMC10476666.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10225844","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Accuracy of Low-Cost, Smartphone-Based Retinal Photography for Diabetic Retinopathy Screening: A Systematic Review. 基于智能手机的低成本视网膜摄影在糖尿病视网膜病变筛查中的准确性:系统回顾
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-08-18 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S416422
Mohammad Eko Prayogo, Alfia Fatma Zaharo, Novandriati Nur Rizky Damayanti, Felicia Widyaputri, Jarir At Thobari, Vina Yanti Susanti, Muhammad Bayu Sasongko

Purpose: Diabetic retinopathy (DR) is a leading cause of blindness. Early DR screening is essential, but the infrastructure can be less affordable in low resource countries. This study aims to review the accuracy of low-cost smartphone-based fundus cameras for DR screening in adult patients with diabetes.

Methods: We performed a systematic literature search to find studies that reported the sensitivity and specificity of low-cost smartphone-based devices for fundus photography in adult patients with diabetes. We searched three databases (MEDLINE, Google Scholar, Scopus) and one register (Cochrane CENTRAL). We presented the accuracy values by grouping the diagnosis into three: any DR, referrable DR, and diabetic macular oedema (DMO). Risk of bias and applicability of the studies were assessed using QUADAS-2.

Results: Five out of 294 retrieved records were included with a total of six smartphone-based devices reviewed. All of the reference diagnostic methods used in the included studies were either indirect ophthalmoscopy or slit-lamp examinations and all smartphone-based devices' imaging protocols used mydriatic drops. The reported sensitivity and specificity for any DR were 52-92.2% and 73.3-99%; for referral DR were 21-91.4% and 64.9-100%; and for DMO were 29.4-81% and 95-100%, respectively.

Conclusion: Sensitivity available low-cost smartphone-based devices for DR screening were acceptable and their specificity particularly for detecting referrable DR and DMO were considerably good. These findings support their potential utilization for DR screening in a low resources setting.

目的:糖尿病视网膜病变(DR)是导致失明的主要原因。早期糖尿病视网膜病变筛查至关重要,但在资源匮乏的国家,基础设施的负担能力可能较低。本研究旨在回顾基于低成本智能手机的眼底照相机对成年糖尿病患者进行糖尿病视网膜病变筛查的准确性:我们进行了系统的文献检索,以找到报道基于低成本智能手机的眼底照相设备在成年糖尿病患者中的灵敏度和特异性的研究。我们检索了三个数据库(MEDLINE、Google Scholar、Scopus)和一个登记册(Cochrane CENTRAL)。我们将诊断分为三类:任何DR、可转诊DR和糖尿病性黄斑水肿(DMO),并给出了准确率值。我们使用 QUADAS-2 评估了研究的偏倚风险和适用性:结果:在检索到的 294 份记录中,有 5 份被纳入,共审查了 6 种基于智能手机的设备。所有纳入研究的参考诊断方法均为间接眼底镜检查或裂隙灯检查,所有基于智能手机的设备的成像方案均使用了催眠滴眼液。报告显示,任何DR的敏感性和特异性分别为52-92.2%和73.3-99%;转诊DR的敏感性和特异性分别为21-91.4%和64.9-100%;DMO的敏感性和特异性分别为29.4-81%和95-100%:可用于 DR 筛查的低成本智能手机设备的灵敏度可以接受,其特异性,尤其是检测可转诊 DR 和 DMO 的特异性相当好。这些研究结果支持在资源匮乏的环境中使用智能手机筛查 DR。
{"title":"Accuracy of Low-Cost, Smartphone-Based Retinal Photography for Diabetic Retinopathy Screening: A Systematic Review.","authors":"Mohammad Eko Prayogo, Alfia Fatma Zaharo, Novandriati Nur Rizky Damayanti, Felicia Widyaputri, Jarir At Thobari, Vina Yanti Susanti, Muhammad Bayu Sasongko","doi":"10.2147/OPTH.S416422","DOIUrl":"10.2147/OPTH.S416422","url":null,"abstract":"<p><strong>Purpose: </strong>Diabetic retinopathy (DR) is a leading cause of blindness. Early DR screening is essential, but the infrastructure can be less affordable in low resource countries. This study aims to review the accuracy of low-cost smartphone-based fundus cameras for DR screening in adult patients with diabetes.</p><p><strong>Methods: </strong>We performed a systematic literature search to find studies that reported the sensitivity and specificity of low-cost smartphone-based devices for fundus photography in adult patients with diabetes. We searched three databases (MEDLINE, Google Scholar, Scopus) and one register (Cochrane CENTRAL). We presented the accuracy values by grouping the diagnosis into three: any DR, referrable DR, and diabetic macular oedema (DMO). Risk of bias and applicability of the studies were assessed using QUADAS-2.</p><p><strong>Results: </strong>Five out of 294 retrieved records were included with a total of six smartphone-based devices reviewed. All of the reference diagnostic methods used in the included studies were either indirect ophthalmoscopy or slit-lamp examinations and all smartphone-based devices' imaging protocols used mydriatic drops. The reported sensitivity and specificity for any DR were 52-92.2% and 73.3-99%; for referral DR were 21-91.4% and 64.9-100%; and for DMO were 29.4-81% and 95-100%, respectively.</p><p><strong>Conclusion: </strong>Sensitivity available low-cost smartphone-based devices for DR screening were acceptable and their specificity particularly for detecting referrable DR and DMO were considerably good. These findings support their potential utilization for DR screening in a low resources setting.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2459-2470"},"PeriodicalIF":1.8,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b4/40/opth-17-2459.PMC10443682.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10421761","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Neurofilament Light Chain in Aqueous Humor as a Marker of Neurodegeneration in Glaucoma. 作为青光眼神经变性标志物的眼液中的神经丝轻链
IF 2.2 Q3 OPHTHALMOLOGY Pub Date : 2023-08-02 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S417664
Jonathan B Lin, Kristen M Pitts, Hani El Helwe, Cameron Neeson, Nathan E Hall, Henisk Falah, Stephanie A Schultz, Silas L Wang, Kristine Lo, Christian Song, Milica A Margeta, David Solá-Del Valle

Purpose: Neurofilament light chain (NfL) is a neuronal cytoskeletal protein that has been identified as a marker of neurodegeneration in diseases of the central nervous system. In this study, we investigated whether NfL in the aqueous humor (AH) can serve as a marker of neurodegeneration in glaucoma in a racially diverse North American population.

Design: Single-center, case-control study.

Participants: We enrolled patients with various types and stages of glaucoma undergoing planned ophthalmic surgery as part of their routine care and compared them with patients without glaucoma undergoing phacoemulsification for age-related cataract.

Methods: We collected AH from 39 glaucoma patients and 10 patients without glaucoma. AH NfL was quantified using the Single-Molecule Array (Simoa)® NF-light assay (Quanterix). Demographic information, such as age, body mass index, sex, and self-reported race, as well as clinical information, such as pre-operative intraocular pressure (IOP), maximum IOP, and number of pre-operative glaucoma medications, was obtained by reviewing the medical record.

Main outcome measures: Levels of AH NfL.

Results: In a model controlling for age and body mass index (BMI), NfL was significantly elevated in AH from glaucoma patients (mean: 429 pg/mL; standard deviation [SD]: 1136 pg/mL) compared to AH from patients without glaucoma (mean: 3.1 pg/mL; SD: 1.9 pg/mg): P = 0.002. Higher AH NfL was associated with higher maximum IOP (R = 0.44, P = 0.005), higher pre-operative IOP (R = 0.46, P = 0.003), and more pre-operative glaucoma medications (Rs = 0.61, P < 0.001). There was no association between AH NfL and Humphrey visual field mean deviation (R = -0.20, P = 0.220), retinal nerve fiber layer thickness as measured with optical coherence tomography (R = 0.07, P = 0.694), or glaucoma stage (Rs = 0.015, P = 0.935).

Conclusion: Our findings suggest that AH NfL may have clinical utility as a marker of glaucomatous neurodegeneration.

目的:神经丝蛋白轻链(NfL)是一种神经元细胞骨架蛋白,已被确定为中枢神经系统疾病中神经变性的标志物。在这项研究中,我们调查了在不同种族的北美人群中,房水(AH)中的 NfL 是否可作为青光眼神经变性的标志物:设计:单中心病例对照研究:我们招募了各种类型和阶段的青光眼患者,作为常规护理的一部分,他们计划接受眼科手术,并与接受超声乳化术治疗老年性白内障的无青光眼患者进行比较:我们收集了 39 名青光眼患者和 10 名无青光眼患者的 AH。使用单分子阵列(Simoa)® NF-光测定法(Quanterix)对AH NfL进行量化。人口统计学信息,如年龄、体重指数、性别和自我报告的种族,以及临床信息,如术前眼压(IOP)、最高眼压和术前青光眼用药次数,均通过查看病历获得:结果:结果:在控制年龄和体重指数(BMI)的模型中,与无青光眼患者的AH(平均:3.1 pg/mL;SD:1.9 pg/mg)相比,青光眼患者的AH的NfL显著升高(平均:429 pg/mL;标准差[SD]:1136 pg/mL):P = 0.002.较高的 AH NfL 与较高的最大眼压(R = 0.44,P = 0.005)、较高的术前眼压(R = 0.46,P = 0.003)和较多的术前青光眼药物(Rs = 0.61,P < 0.001)相关。AH NfL与Humphrey视野平均偏差(R = -0.20,P = 0.220)、光学相干断层扫描测量的视网膜神经纤维层厚度(R = 0.07,P = 0.694)或青光眼分期(Rs = 0.015,P = 0.935)之间没有关联:我们的研究结果表明,AH NfL 可作为青光眼神经变性的临床标记物。
{"title":"Neurofilament Light Chain in Aqueous Humor as a Marker of Neurodegeneration in Glaucoma.","authors":"Jonathan B Lin, Kristen M Pitts, Hani El Helwe, Cameron Neeson, Nathan E Hall, Henisk Falah, Stephanie A Schultz, Silas L Wang, Kristine Lo, Christian Song, Milica A Margeta, David Solá-Del Valle","doi":"10.2147/OPTH.S417664","DOIUrl":"10.2147/OPTH.S417664","url":null,"abstract":"<p><strong>Purpose: </strong>Neurofilament light chain (NfL) is a neuronal cytoskeletal protein that has been identified as a marker of neurodegeneration in diseases of the central nervous system. In this study, we investigated whether NfL in the aqueous humor (AH) can serve as a marker of neurodegeneration in glaucoma in a racially diverse North American population.</p><p><strong>Design: </strong>Single-center, case-control study.</p><p><strong>Participants: </strong>We enrolled patients with various types and stages of glaucoma undergoing planned ophthalmic surgery as part of their routine care and compared them with patients without glaucoma undergoing phacoemulsification for age-related cataract.</p><p><strong>Methods: </strong>We collected AH from 39 glaucoma patients and 10 patients without glaucoma. AH NfL was quantified using the Single-Molecule Array (Simoa)<sup>®</sup> NF-light assay (Quanterix). Demographic information, such as age, body mass index, sex, and self-reported race, as well as clinical information, such as pre-operative intraocular pressure (IOP), maximum IOP, and number of pre-operative glaucoma medications, was obtained by reviewing the medical record.</p><p><strong>Main outcome measures: </strong>Levels of AH NfL.</p><p><strong>Results: </strong>In a model controlling for age and body mass index (BMI), NfL was significantly elevated in AH from glaucoma patients (mean: 429 pg/mL; standard deviation [SD]: 1136 pg/mL) compared to AH from patients without glaucoma (mean: 3.1 pg/mL; SD: 1.9 pg/mg): P = 0.002. Higher AH NfL was associated with higher maximum IOP (R = 0.44, P = 0.005), higher pre-operative IOP (R = 0.46, P = 0.003), and more pre-operative glaucoma medications (R<sub>s</sub> = 0.61, P < 0.001). There was no association between AH NfL and Humphrey visual field mean deviation (R = -0.20, P = 0.220), retinal nerve fiber layer thickness as measured with optical coherence tomography (R = 0.07, P = 0.694), or glaucoma stage (R<sub>s</sub> = 0.015, P = 0.935).</p><p><strong>Conclusion: </strong>Our findings suggest that AH NfL may have clinical utility as a marker of glaucomatous neurodegeneration.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2209-2217"},"PeriodicalIF":2.2,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/17/6f/opth-17-2209.PMC10404437.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9950552","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Eyes for Ears: Usage and Efficacy of a Podcast for Ophthalmic Education. 耳朵的眼睛:眼科教育播客的使用和效果。
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-07-28 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S413795
Andrew E Pouw, Fei Cai, Amanda J Redfern, Jessica Chow, Benjamin K Young

Purpose: To characterize listenership and perceived educational impact of the ophthalmic podcast "Eyes for Ears".

Methods: A cross-sectional, internet-distributed, 9-question Qualtrics survey was made available to podcast listeners. Listenership metrics were analyzed from the podcast host platform.

Results: From January 10, 2019 to September 2, 2021, the podcast was downloaded over 422,000 times, averaging about 4442 downloads per episode. 209 Qualtrics survey responses were analyzed from podcast listeners with backgrounds in eye care including medical students, residents, fellows, clinicians and technicians. The majority were residents (60.3%), representative of the target audience of the podcast. Listeners reported using the podcast while commuting (81.3%), felt it increased the time they could spend on self-care (63.2%), and thought it improved their fund of knowledge (99.0%). Respondents recalled feeling better prepared for the OKAP or written boards after using this podcast (before median = 50/100 on Likert Scale, IQR 30-65 vs median = 70/100, IQR 56-81, p <0.001). Respondents identified question banks as the most helpful for OKAP studying, followed by podcasts. Podcasts were preferred over articles and lectures in terms of helpfulness (p < 0.001).

Conclusion: The Eyes for Ears podcast has achieved a robust international audience. The surveyed audience felt the podcast was useful for their education and well-being.

目的:了解眼科播客 "Eyes for Ears "的收听情况和感知到的教育影响:方法: 在互联网上向播客听众发放一份包含 9 个问题的 Qualtrics 问卷调查。结果:从 2019 年 1 月 10 日到 9 月 2 日,播客的收听率达到了 100%:从 2019 年 1 月 10 日到 2021 年 9 月 2 日,播客的下载量超过 42.2 万次,平均每集下载量约为 4442 次。对 209 份 Qualtrics 调查回复进行了分析,这些播客听众具有眼科护理背景,包括医学生、住院医师、研究员、临床医师和技术人员。大多数听众是住院医师(60.3%),代表了播客的目标受众。收听者表示在通勤时使用播客(81.3%),认为播客增加了他们用于自我护理的时间(63.2%),并认为播客提高了他们的知识储备(99.0%)。受访者回忆说,在使用该播客之后,他们觉得自己为 OKAP 或书面考试做了更好的准备(之前李克特量表的中位数 = 50/100,IQR 30-65 vs 中位数 = 70/100,IQR 56-81,p 结论:"在使用该播客后,受访者觉得自己为 OKAP 或书面考试做了更好的准备:Eyes for Ears 播客在国际上拥有众多受众。接受调查的听众认为播客对他们的教育和身心健康很有帮助。
{"title":"Eyes for Ears: Usage and Efficacy of a Podcast for Ophthalmic Education.","authors":"Andrew E Pouw, Fei Cai, Amanda J Redfern, Jessica Chow, Benjamin K Young","doi":"10.2147/OPTH.S413795","DOIUrl":"10.2147/OPTH.S413795","url":null,"abstract":"<p><strong>Purpose: </strong>To characterize listenership and perceived educational impact of the ophthalmic podcast \"Eyes for Ears\".</p><p><strong>Methods: </strong>A cross-sectional, internet-distributed, 9-question Qualtrics survey was made available to podcast listeners. Listenership metrics were analyzed from the podcast host platform.</p><p><strong>Results: </strong>From January 10, 2019 to September 2, 2021, the podcast was downloaded over 422,000 times, averaging about 4442 downloads per episode. 209 Qualtrics survey responses were analyzed from podcast listeners with backgrounds in eye care including medical students, residents, fellows, clinicians and technicians. The majority were residents (60.3%), representative of the target audience of the podcast. Listeners reported using the podcast while commuting (81.3%), felt it increased the time they could spend on self-care (63.2%), and thought it improved their fund of knowledge (99.0%). Respondents recalled feeling better prepared for the OKAP or written boards after using this podcast (before median = 50/100 on Likert Scale, IQR 30-65 vs median = 70/100, IQR 56-81, p <0.001). Respondents identified question banks as the most helpful for OKAP studying, followed by podcasts. Podcasts were preferred over articles and lectures in terms of helpfulness (p < 0.001).</p><p><strong>Conclusion: </strong>The Eyes for Ears podcast has achieved a robust international audience. The surveyed audience felt the podcast was useful for their education and well-being.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2163-2170"},"PeriodicalIF":1.8,"publicationDate":"2023-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3f/48/opth-17-2163.PMC10392787.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9933535","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis. 使用由硫酸软骨素-透明质酸组成的眼科粘手术装置白内障手术后的角膜预后:系统综述和荟萃分析。
IF 2.2 Q3 OPHTHALMOLOGY Pub Date : 2023-07-24 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S419863
Chia-Wen Hsiao, Hang Cheng, Rana Ghafouri, Nicole C Ferko, Brandon D Ayres

Background: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT).

Methods: MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N ≥ 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT®, DuoVisc® or DisCoVisc®) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs.

Results: A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: -4.10%; 95% CI: -5.81 to -2.40; p < 0.0001; 9 studies) and HPMC (MD: -6.47%; 95% CI: -10.41 to -2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: -3.22%; 95% CI: -6.24% to -0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: -0.43% to 0.95%; p = 0.4; 2 studies).

Conclusion: CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings.

背景:眼球粘手术装置(OVDs)是白内障手术中常用的保护角膜内皮的装置。通过系统的文献回顾和荟萃分析来评估由硫酸软骨素-透明质酸(CS-HA)组成的ovd与其他ovd在维持内皮细胞密度(ECD)和角膜厚度(CT)方面的临床证据。方法:检索2000 ~ 2020年的MEDLINE和EMBASE数据库。纳入比较含有CS-HA的OVD(即VISCOAT®、DuoVisc®或DisCoVisc®)与任何其他OVD的随机对照试验(rct,每组N≥20)。鉴定的比较物仅限于文献中发现的ovd,其中包括仅ha或羟丙基甲基纤维素(HPMC)组成的ovd。重点结果包括ECD(基线至3个月)和CT(基线至24小时)的变化。使用R软件进行meta分析,以评估CS-HA ovd与HA-only或HPMC ovd之间ECD和CT变化的平均差异(MD)。结果:共筛选966篇摘要,从12项随机对照试验中提取数据。使用随机效应模型的荟萃分析显示,与仅ha (MD: -4.10%; 95% CI: -5.81至-2.40;p < 0.0001; 9项研究)和HPMC (MD: -6.47%; 95% CI: -10.41至-2.52;p = 0.001; 2项研究)产品相比,CS-HA ovd的ECD下降百分比(%)显著降低。同样,CS-HA组的CT增加百分比明显低于单纯ha组(MD: -3.22%; 95% CI: -6.24%至-0.20%;p = 0.04; 4项研究)。然而,当比较CS-HA和HPMC OVDs之间的CT百分比变化时,没有显著差异(MD: 2.65%; 95% CI: -0.43%至0.95%;p = 0.4; 2项研究)。结论:与其他ovd相比,CS-HA ovd术后内皮细胞损失较小,可更好地保护白内障手术过程中的角膜内皮。未来可能需要随机研究来巩固这些发现。
{"title":"Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis.","authors":"Chia-Wen Hsiao, Hang Cheng, Rana Ghafouri, Nicole C Ferko, Brandon D Ayres","doi":"10.2147/OPTH.S419863","DOIUrl":"10.2147/OPTH.S419863","url":null,"abstract":"<p><strong>Background: </strong>Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT).</p><p><strong>Methods: </strong>MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N ≥ 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT<sup>®</sup>, DuoVisc<sup>®</sup> or DisCoVisc<sup>®</sup>) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs.</p><p><strong>Results: </strong>A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: -4.10%; 95% CI: -5.81 to -2.40; p < 0.0001; 9 studies) and HPMC (MD: -6.47%; 95% CI: -10.41 to -2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: -3.22%; 95% CI: -6.24% to -0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: -0.43% to 0.95%; p = 0.4; 2 studies).</p><p><strong>Conclusion: </strong>CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2083-2096"},"PeriodicalIF":2.2,"publicationDate":"2023-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f0/13/opth-17-2083.PMC10378560.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10267876","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Interobserver Reliability of Tear Break-Up Time Examination Using "Smart Eye Camera" in Indonesian Remote Area. 印尼偏远地区“智能眼相机”泪液破裂时间检测的观察者间信度
IF 2.2 Q3 OPHTHALMOLOGY Pub Date : 2023-07-24 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S412233
Ariesanti Tri Handayani, Clara Valentina, I Gusti Ayu Ratna Suryaningrum, Putu Dian Megasafitri, I Gusti Ayu Made Juliari, Ida Ayu Ary Pramita, Shintaro Nakayama, Eisuke Shimizu, Anak Agung Mas Putrawati Triningrat

Introduction: Dry eye disease (DED) is a multifactorial disease of tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear film instability leading to decrease of vision, productivity and quality of life, and blindness. DED diagnosis remains difficult and underdiagnosed regarding inconsistency between subjective symptoms and clinical findings. Tear break-up time (TBUT) is an objective indicator of tear film stability in diagnostic DED. A novel smartphone attachment, namely SEC (smart eye camera), could mimic conventional slit lamp to assess TBUT and beneficial in facilitating DED diagnosis. Reliability between a non and an ophthalmologist in TBUT assessment and DED diagnosis is observed in this study.

Purpose: To determine interobserver reliability of TBUT measurement for diagnosing DED using SEC.

Design: This a cross-sectional analytic study involving 99 participants (198 eyes) aged 40 years who visited Pratama Gema Santi Hospital, Nusa Penida, from September 2nd to 4th, 2022, with consecutive sampling technique.

Methods: Fluoresceined eyes were filmed using the SEC device and apps, continued by masked ophthalmologist and resident assessing TBUT based on the video. The primary outcome is interobserver reliability for TBUT measurement and DED diagnosis.

Results: The mean age of participants was 55.22±9.78 years, 48.5% male and 51.5% female. The reliability of interobserver in assessing DED based on TBUT test is 0.78 (95% CI=0.31-1.26, P-value=0.001), and interobserver reliability in diagnosing DED based on OSDI and TBUT showed good agreement (weighted kappa=0.71). Good interobserver reliability underscores that non-ophthalmologists can diagnose DED based on TBUT video using SEC.

Conclusion: SEC video has good interobserver reliability to assess TBUT for DED diagnosis. SEC can be used as one of the methods in assessing DED in limited health care facilities. The high reliability of interobserver assessment indicates that DED diagnosis using video taken with SEC may be useful for telemedicine evaluation in remote areas.

简介:干眼病(DED)是一种多因素的泪液和眼表疾病,其症状包括不适、视力障碍和泪膜不稳定,导致视力、生产力和生活质量下降,甚至失明。由于主观症状与临床表现不一致,DED诊断仍然困难且诊断不足。撕裂破裂时间(TBUT)是诊断性DED中泪膜稳定性的客观指标。一种新的智能手机附件,即SEC(智能眼摄像头),可以模仿传统的裂隙灯来评估TBUT,有助于促进DED的诊断。本研究观察了非眼科医生和眼科医生在TBUT评估和DED诊断中的可靠性。设计:采用连续抽样技术,对2022年9月2日至4日在Nusa Penida的Pratama Gema Santi医院就诊的99名40岁的参与者(198只眼)进行横断面分析研究。方法:使用SEC设备和应用程序拍摄荧光眼睛,由蒙面眼科医生和住院医师根据视频继续评估TBUT。主要结局是TBUT测量和DED诊断的观察者间信度。结果:参与者平均年龄55.22±9.78岁,男性48.5%,女性51.5%。基于TBUT检验评估DED的观察者间信度为0.78 (95% CI=0.31 ~ 1.26, p值=0.001),基于OSDI和TBUT诊断DED的观察者间信度一致性较好(加权kappa=0.71)。结论:SEC视频对TBUT诊断DED具有良好的观察者间信度。SEC可作为有限医疗机构DED评估的方法之一。观察者间评估的高可靠性表明,使用SEC拍摄的视频诊断DED可能对偏远地区的远程医疗评估有用。
{"title":"Interobserver Reliability of Tear Break-Up Time Examination Using \"Smart Eye Camera\" in Indonesian Remote Area.","authors":"Ariesanti Tri Handayani, Clara Valentina, I Gusti Ayu Ratna Suryaningrum, Putu Dian Megasafitri, I Gusti Ayu Made Juliari, Ida Ayu Ary Pramita, Shintaro Nakayama, Eisuke Shimizu, Anak Agung Mas Putrawati Triningrat","doi":"10.2147/OPTH.S412233","DOIUrl":"10.2147/OPTH.S412233","url":null,"abstract":"<p><strong>Introduction: </strong>Dry eye disease (DED) is a multifactorial disease of tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear film instability leading to decrease of vision, productivity and quality of life, and blindness. DED diagnosis remains difficult and underdiagnosed regarding inconsistency between subjective symptoms and clinical findings. Tear break-up time (TBUT) is an objective indicator of tear film stability in diagnostic DED. A novel smartphone attachment, namely SEC (smart eye camera), could mimic conventional slit lamp to assess TBUT and beneficial in facilitating DED diagnosis. Reliability between a non and an ophthalmologist in TBUT assessment and DED diagnosis is observed in this study.</p><p><strong>Purpose: </strong>To determine interobserver reliability of TBUT measurement for diagnosing DED using SEC.</p><p><strong>Design: </strong>This a cross-sectional analytic study involving 99 participants (198 eyes) aged 40 years who visited Pratama Gema Santi Hospital, Nusa Penida, from September 2nd to 4th, 2022, with consecutive sampling technique.</p><p><strong>Methods: </strong>Fluoresceined eyes were filmed using the SEC device and apps, continued by masked ophthalmologist and resident assessing TBUT based on the video. The primary outcome is interobserver reliability for TBUT measurement and DED diagnosis.</p><p><strong>Results: </strong>The mean age of participants was 55.22±9.78 years, 48.5% male and 51.5% female. The reliability of interobserver in assessing DED based on TBUT test is 0.78 (95% CI=0.31-1.26, <i>P</i>-value=0.001), and interobserver reliability in diagnosing DED based on OSDI and TBUT showed good agreement (weighted kappa=0.71). Good interobserver reliability underscores that non-ophthalmologists can diagnose DED based on TBUT video using SEC.</p><p><strong>Conclusion: </strong>SEC video has good interobserver reliability to assess TBUT for DED diagnosis. SEC can be used as one of the methods in assessing DED in limited health care facilities. The high reliability of interobserver assessment indicates that DED diagnosis using video taken with SEC may be useful for telemedicine evaluation in remote areas.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"2097-2107"},"PeriodicalIF":2.2,"publicationDate":"2023-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/66/cd/opth-17-2097.PMC10378626.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10267875","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Impact of the COVID-19 Pandemic on Wait-Times for Ophthalmic Surgery in Ontario, Canada: A Population-Based Study. COVID-19 大流行对加拿大安大略省眼科手术等待时间的影响:基于人口的研究。
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-06-26 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S409479
Michael Balas, Diana Vasiliu, Gener Austria, Tina Felfeli

Objective: To investigate the effects of the COVID-19 pandemic on case volumes and wait-times for ophthalmic surgery in Ontario, Canada.

Design: Population-based retrospective cohort study.

Participants: Patients undergoing ophthalmic surgery in Ontario, Canada, from 2010 to 2021, collected from the Ontario Health Wait Times Information System (WTIS) database.

Methods: The WTIS contains non-emergent surgical case volume and wait-time data for six ophthalmic subspecialty surgery types, three priority levels (low, medium, high) and 14 different regions in Ontario. Case volume and wait-times were compared between the COVID-19 pandemic (2020-2021) and the preceding time period (2010-2019) across all stratifications.

Results: There was a significant decrease in case volumes and significant increase in wait-times across geographic regions, priority levels, and subspecialty surgeries from the pre-pandemic to pandemic period. Moreover, COVID-19 exacerbated pre-existing wait-time disparities between sexes, with females waiting 4.1 days longer than males overall to receive surgery in 2010-2019 compared to waiting 8.8 days longer in 2020-2021 (117% increase).

Conclusion: These findings highlight the impact of the COVID-19 pandemic on ophthalmic surgical wait times in Ontario. Cataract, strabismus and oculoplastic surgeries, the Waterloo Wellington, Central, and South East regions of Ontario, and those with female sex had the greatest relative increases in wait-times during the pandemic.

目的:调查 COVID-19 大流行对加拿大安大略省眼科手术病例数量和等待时间的影响:调查 COVID-19 大流行对加拿大安大略省眼科手术病例数和等待时间的影响:设计:基于人群的回顾性队列研究:从安大略省健康等待时间信息系统(WTIS)数据库中收集的 2010 年至 2021 年期间在加拿大安大略省接受眼科手术的患者:WTIS包含安大略省六个眼科亚专科手术类型、三个优先级别(低、中、高)和14个不同地区的非急诊手术病例数量和等待时间数据。在 COVID-19 大流行期间(2020-2021 年)和之前的时间段(2010-2019 年),对所有分层的病例数量和等待时间进行了比较:结果:从大流行前到大流行期间,不同地理区域、优先级别和亚专科手术的病例数明显减少,等待时间明显增加。此外,COVID-19加剧了两性之间原有的等待时间差异,2010-2019年女性接受手术的总等待时间比男性多4.1天,而2020-2021年女性接受手术的总等待时间比男性多8.8天(增加了117%):这些发现凸显了 COVID-19 大流行对安大略省眼科手术等待时间的影响。在大流行期间,白内障、斜视和眼部整形手术、安大略省滑铁卢惠灵顿、中部和东南部地区以及女性患者的等待时间相对增加最多。
{"title":"The Impact of the COVID-19 Pandemic on Wait-Times for Ophthalmic Surgery in Ontario, Canada: A Population-Based Study.","authors":"Michael Balas, Diana Vasiliu, Gener Austria, Tina Felfeli","doi":"10.2147/OPTH.S409479","DOIUrl":"10.2147/OPTH.S409479","url":null,"abstract":"<p><strong>Objective: </strong>To investigate the effects of the COVID-19 pandemic on case volumes and wait-times for ophthalmic surgery in Ontario, Canada.</p><p><strong>Design: </strong>Population-based retrospective cohort study.</p><p><strong>Participants: </strong>Patients undergoing ophthalmic surgery in Ontario, Canada, from 2010 to 2021, collected from the Ontario Health Wait Times Information System (WTIS) database.</p><p><strong>Methods: </strong>The WTIS contains non-emergent surgical case volume and wait-time data for six ophthalmic subspecialty surgery types, three priority levels (low, medium, high) and 14 different regions in Ontario. Case volume and wait-times were compared between the COVID-19 pandemic (2020-2021) and the preceding time period (2010-2019) across all stratifications.</p><p><strong>Results: </strong>There was a significant decrease in case volumes and significant increase in wait-times across geographic regions, priority levels, and subspecialty surgeries from the pre-pandemic to pandemic period. Moreover, COVID-19 exacerbated pre-existing wait-time disparities between sexes, with females waiting 4.1 days longer than males overall to receive surgery in 2010-2019 compared to waiting 8.8 days longer in 2020-2021 (117% increase).</p><p><strong>Conclusion: </strong>These findings highlight the impact of the COVID-19 pandemic on ophthalmic surgical wait times in Ontario. Cataract, strabismus and oculoplastic surgeries, the Waterloo Wellington, Central, and South East regions of Ontario, and those with female sex had the greatest relative increases in wait-times during the pandemic.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"1823-1831"},"PeriodicalIF":1.8,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6f/ef/opth-17-1823.PMC10312341.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9737090","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Posterior Pole Asymmetry Analysis as a Diagnostic Tool in Glaucoma Suspects: An Electrophysiological Approach. 作为青光眼疑似患者诊断工具的后极不对称分析:电生理学方法。
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-06-21 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S411647
Andrew Tirsi, Paras P Shah, Vasiliki Gliagias, Daniel Barmas-Alamdari, Derek Orshan, Joby Tsai, Celso Tello

Purpose: Spectral domain optical coherence tomography (SD-OCT) with posterior pole asymmetry analysis (PPAA) provides a mapping of posterior pole retinal thickness with asymmetry analysis between hemispheres of each eye. We investigated whether these structural abnormalities were correlated with functional retinal ganglion cell (RGC) loss, quantified by steady state pattern electroretinogram (ssPERG), in glaucoma suspects (GS).

Methods: Twenty GS (34 eyes) were enrolled in a prospective study at the Manhattan Eye, Ear, and Throat Hospital. All subjects underwent ophthalmological examination, including Humphrey visual field, Spectralis Glaucoma Module Premium Edition (GMPE) SD-OCT PPAA, and ssPERG testing. The ability of ssPERG parameters (Magnitude [Mag, µv], MagnitudeD [MagD, µv], and MagD/Mag ratio) to predict PPAA thickness (total, superior, and inferior thickness, [µm]) was tested via adjusted multivariate linear regression analysis.

Results: Mag explained 8% of variance in total PPAA change (F(1,29)=6.33, B=6.86, 95% CI: 1.29-12.44, p=0.018), 8% in superior PPAA change (F(1,29)=5.57, B=6.92, 95% CI: 0.92-12.92, p=0.025), and 7.1% in inferior PPAA change (F(1,29)=5.83, B=6.80, 95% CI: 1.04-12.56, p=0.022). Similarly, MagD explained 9.7% of variance in total PPAA change (F(1,29)=8.09, B=6.47, 95% CI: 1.82-11.13, p=0.008), 10% in superior PPAA change (F(1,29)=7.33, B=6.63, 95% CI: 1.62-11.63, p=0.011), and 8.5% in inferior PPAA change (F(1,29)=7.25, B=6.36, 95% CI: 1.53-11.18, p=0.012). MagD/Mag ratio and PPAA were not significantly associated.

Conclusion: To the best of our knowledge, this is the first study demonstrating a positive relationship between RGC dysfunction and retinal thickness changes between the superior and inferior hemispheres. The detection of asymmetrical structural loss, combined with functional RGC assessment using ssPERG, may be an informative tool for early glaucoma diagnosis.

目的:带后极不对称分析(PPAA)的光谱域光学相干断层扫描(SD-OCT)可绘制后极视网膜厚度图,并对每只眼睛的半球进行不对称分析。我们研究了这些结构异常是否与青光眼疑似患者(GS)的功能性视网膜神经节细胞(RGC)缺失相关(通过稳态模式视网膜电图(ssPERG)量化):曼哈顿眼耳鼻喉科医院的一项前瞻性研究招募了 20 名青光眼疑似患者(34 只眼)。所有受试者均接受了眼科检查,包括汉弗莱视野、Spectralis Glaucoma Module Premium Edition (GMPE) SD-OCT PPAA 和 ssPERG 测试。通过调整后的多元线性回归分析,测试了ssPERG参数(Magnitude [Mag,µv]、MagnitudeD [MagD,µv]和MagD/Mag比值)预测PPAA厚度(总厚度、上部厚度和下部厚度,[µm])的能力:Mag解释了PPAA总厚度变化8%的方差(F(1,29)=6.33, B=6.86, 95% CI: 1.29-12.44, p=0.018),解释了PPAA上厚度变化8%的方差(F(1,29)=5.57,B=6.92,95% CI:0.92-12.92,p=0.025),下部 PPAA 变化为 7.1%(F(1,29)=5.83,B=6.80,95% CI:1.04-12.56,p=0.022)。同样,MagD 可解释 9.7% 的 PPAA 总变化方差(F(1,29)=8.09, B=6.47, 95% CI: 1.82-11.13, p=0.008),10% 的 PPAA 上位变化方差(F(1,29)=7.33,B=6.63,95% CI:1.62-11.63,p=0.011),下部 PPAA 变化为 8.5%(F(1,29)=7.25,B=6.36,95% CI:1.53-11.18,p=0.012)。MagD/Mag比值与PPAA无明显相关性:据我们所知,这是首次有研究表明 RGC 功能障碍与上下半球视网膜厚度变化之间存在正相关关系。利用ssPERG检测非对称结构性损失并结合功能性RGC评估,可能是早期青光眼诊断的一种信息工具。
{"title":"Posterior Pole Asymmetry Analysis as a Diagnostic Tool in Glaucoma Suspects: An Electrophysiological Approach.","authors":"Andrew Tirsi, Paras P Shah, Vasiliki Gliagias, Daniel Barmas-Alamdari, Derek Orshan, Joby Tsai, Celso Tello","doi":"10.2147/OPTH.S411647","DOIUrl":"10.2147/OPTH.S411647","url":null,"abstract":"<p><strong>Purpose: </strong>Spectral domain optical coherence tomography (SD-OCT) with posterior pole asymmetry analysis (PPAA) provides a mapping of posterior pole retinal thickness with asymmetry analysis between hemispheres of each eye. We investigated whether these structural abnormalities were correlated with functional retinal ganglion cell (RGC) loss, quantified by steady state pattern electroretinogram (ssPERG), in glaucoma suspects (GS).</p><p><strong>Methods: </strong>Twenty GS (34 eyes) were enrolled in a prospective study at the Manhattan Eye, Ear, and Throat Hospital. All subjects underwent ophthalmological examination, including Humphrey visual field, Spectralis Glaucoma Module Premium Edition (GMPE) SD-OCT PPAA, and ssPERG testing. The ability of ssPERG parameters (Magnitude [Mag, µv], MagnitudeD [MagD, µv], and MagD/Mag ratio) to predict PPAA thickness (total, superior, and inferior thickness, [µm]) was tested via adjusted multivariate linear regression analysis.</p><p><strong>Results: </strong>Mag explained 8% of variance in total PPAA change (F(1,29)=6.33, B=6.86, 95% CI: 1.29-12.44, p=0.018), 8% in superior PPAA change (F(1,29)=5.57, B=6.92, 95% CI: 0.92-12.92, p=0.025), and 7.1% in inferior PPAA change (F(1,29)=5.83, B=6.80, 95% CI: 1.04-12.56, p=0.022). Similarly, MagD explained 9.7% of variance in total PPAA change (F(1,29)=8.09, B=6.47, 95% CI: 1.82-11.13, p=0.008), 10% in superior PPAA change (F(1,29)=7.33, B=6.63, 95% CI: 1.62-11.63, p=0.011), and 8.5% in inferior PPAA change (F(1,29)=7.25, B=6.36, 95% CI: 1.53-11.18, p=0.012). MagD/Mag ratio and PPAA were not significantly associated.</p><p><strong>Conclusion: </strong>To the best of our knowledge, this is the first study demonstrating a positive relationship between RGC dysfunction and retinal thickness changes between the superior and inferior hemispheres. The detection of asymmetrical structural loss, combined with functional RGC assessment using ssPERG, may be an informative tool for early glaucoma diagnosis.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"1777-1787"},"PeriodicalIF":1.8,"publicationDate":"2023-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/82/b4/opth-17-1777.PMC10290849.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10077029","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Glycated Hemoglobin Improvement After Medical and Surgical Eye Care in American Veterans Involves Multidisciplinary Care. 美国退伍军人内科和外科眼科护理后糖化血红蛋白的改善涉及多学科护理。
IF 1.8 Q3 OPHTHALMOLOGY Pub Date : 2023-06-10 eCollection Date: 2023-01-01 DOI: 10.2147/OPTH.S412187
Christopher M Santilli, Shaun Johnson, Coltt R Thunstrom, Karen R Armbrust

Purpose: The effects of diabetes mellitus (DM) on visual function have been extensively studied. Fewer studies evaluate the effect of visual function on DM, and previous small studies have shown mixed results concerning the relationship between glycated hemoglobin (HbA1c) and cataract surgery. We performed a retrospective, observational, single-site study at a Veterans hospital to evaluate this relationship and the relationship between HbA1c and non-surgical eye care.

Patients and methods: We compared pre- and post-operative/examination HbA1c in 431 surgical and 431 matched, non-surgical subjects who underwent eye examination at the same institution. Subgroup analysis was performed by age, elevated (≥8) pre-operative/examination HbA1c, and change in diabetic management. We also assessed for a relationship between changes in best-corrected visual acuity (BCVA) and HbA1c. The Minneapolis Veterans Affairs Health Care System Research Administration determined this study to be Institutional Review Board exempt from the requirements of 38 CFR 16 under Category 4 (iii).

Results: Pairwise comparison of pre- versus post-operative HbA1c trended towards reduction at 3-6 months in all surgical subjects, with a statistically significant reduction in older subjects, and those with higher pre-operative HbA1c. Eye examination subjects experienced a significant HbA1c reduction 3-6 months after eye examination. Reduction in post-operative/examination HbA1c was associated with concurrent change in diabetic management.

Conclusion: We found an overall reduction in HbA1c in diabetic Veterans who interacted with an ophthalmologist, whether for cataract surgery or eye examination. HbA1c reduction was greatest when ophthalmic care was delivered as part of a multidisciplinary care team. Our findings add new evidence to further support the importance of ophthalmic care in patients with DM and suggest improved visual function may facilitate improved glycemic control.

目的:糖尿病(DM)对视觉功能的影响已被广泛研究。很少有研究评估视觉功能对糖尿病的影响,以前的小型研究显示,糖化血红蛋白(HbA1c)与白内障手术之间的关系结果参差不齐。我们在一家退伍军人医院进行了一项回顾性、观察性、单点研究,以评估这种关系以及HbA1c与非手术眼科护理之间的关系。患者和方法:我们比较了在同一机构接受眼科检查的431名手术和431名匹配的非手术受试者的术前和术后/检查HbA1c。根据年龄、术前/检查HbA1c升高(≥8)和糖尿病管理的变化进行亚组分析。我们还评估了最佳矫正视力(BCVA)变化与HbA1c之间的关系。明尼阿波利斯退伍军人事务医疗保健系统研究管理局确定该研究为机构审查委员会,不受38 CFR 16第4(iii)类要求的约束。结果:所有手术受试者术前和术后HbA1c的成对比较在3-6个月时呈下降趋势,老年受试者的HbA1c在统计学上显著下降,以及术前HbA1c较高的患者。眼科检查受试者在眼科检查3-6个月后HbA1c显著降低。术后/检查HbA1c的降低与糖尿病管理的同时变化有关。结论:我们发现,无论是白内障手术还是眼科检查,与眼科医生互动的糖尿病退伍军人的HbA1c总体降低。当眼科护理作为多学科护理团队的一部分提供时,HbA1c的降低最大。我们的研究结果为进一步支持糖尿病患者眼科护理的重要性提供了新的证据,并表明改善视觉功能可能有助于改善血糖控制。
{"title":"Glycated Hemoglobin Improvement After Medical and Surgical Eye Care in American Veterans Involves Multidisciplinary Care.","authors":"Christopher M Santilli, Shaun Johnson, Coltt R Thunstrom, Karen R Armbrust","doi":"10.2147/OPTH.S412187","DOIUrl":"10.2147/OPTH.S412187","url":null,"abstract":"<p><strong>Purpose: </strong>The effects of diabetes mellitus (DM) on visual function have been extensively studied. Fewer studies evaluate the effect of visual function on DM, and previous small studies have shown mixed results concerning the relationship between glycated hemoglobin (HbA1c) and cataract surgery. We performed a retrospective, observational, single-site study at a Veterans hospital to evaluate this relationship and the relationship between HbA1c and non-surgical eye care.</p><p><strong>Patients and methods: </strong>We compared pre- and post-operative/examination HbA1c in 431 surgical and 431 matched, non-surgical subjects who underwent eye examination at the same institution. Subgroup analysis was performed by age, elevated (≥8) pre-operative/examination HbA1c, and change in diabetic management. We also assessed for a relationship between changes in best-corrected visual acuity (BCVA) and HbA1c. The Minneapolis Veterans Affairs Health Care System Research Administration determined this study to be Institutional Review Board exempt from the requirements of 38 CFR 16 under Category 4 (iii).</p><p><strong>Results: </strong>Pairwise comparison of pre- versus post-operative HbA1c trended towards reduction at 3-6 months in all surgical subjects, with a statistically significant reduction in older subjects, and those with higher pre-operative HbA1c. Eye examination subjects experienced a significant HbA1c reduction 3-6 months after eye examination. Reduction in post-operative/examination HbA1c was associated with concurrent change in diabetic management.</p><p><strong>Conclusion: </strong>We found an overall reduction in HbA1c in diabetic Veterans who interacted with an ophthalmologist, whether for cataract surgery or eye examination. HbA1c reduction was greatest when ophthalmic care was delivered as part of a multidisciplinary care team. Our findings add new evidence to further support the importance of ophthalmic care in patients with DM and suggest improved visual function may facilitate improved glycemic control.</p>","PeriodicalId":10442,"journal":{"name":"Clinical ophthalmology","volume":"17 ","pages":"1675-1682"},"PeriodicalIF":1.8,"publicationDate":"2023-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/71/b7/opth-17-1675.PMC10266375.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9654480","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Clinical ophthalmology
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1