Enhancing physical resolution of constructed ladder network for an interleaved winding 提高结构阶梯网的物理分辨率
S. Pramanik, L. Satish
The number of detectable natural frequencies in a frequency response governs the number of sections of the ladder network that can be constructed, starting from the measured frequency response data. This number, particularly in case of interleaved windings, is woefully small rendering the entire exercise pointless. An attempt is described wherein this physical resolution can be enhanced. This is achieved by augmenting the measured driving-point admittance data (of the interleaved winding) with information regarding natural frequencies that are observable, and hence extractable, from an additional measurement of the open-circuited neutral-end voltage spectrum. By this process, a few more additional natural frequencies become available for processing, resulting in a ladder network with an increased physical resolution, i.e., more number of sections. Measurements done on an actual interleaved winding are presented to demonstrate feasibility of the proposed method.
频率响应中可检测的固有频率的数量决定了从测量的频率响应数据开始可以构建的阶梯网络的部分数量。这个数字,特别是在交错缠绕的情况下,小得可怜,使得整个操作毫无意义。本文描述了一种可以增强这种物理分辨率的尝试。这是通过增加测量的驱动点导纳数据来实现的(交错绕组的),这些数据是可以观察到的,因此可以从开路中性端电压谱的额外测量中提取。通过这个过程,一些额外的固有频率可以用于处理,从而形成一个具有更高物理分辨率的阶梯网络,即更多的段数。在实际的交错绕组上进行了测量,以证明所提出方法的可行性。
{"title":"Enhancing physical resolution of constructed ladder network for an interleaved winding","authors":"S. Pramanik, L. Satish","doi":"10.1109/CATCON.2013.6737474","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737474","url":null,"abstract":"The number of detectable natural frequencies in a frequency response governs the number of sections of the ladder network that can be constructed, starting from the measured frequency response data. This number, particularly in case of interleaved windings, is woefully small rendering the entire exercise pointless. An attempt is described wherein this physical resolution can be enhanced. This is achieved by augmenting the measured driving-point admittance data (of the interleaved winding) with information regarding natural frequencies that are observable, and hence extractable, from an additional measurement of the open-circuited neutral-end voltage spectrum. By this process, a few more additional natural frequencies become available for processing, resulting in a ladder network with an increased physical resolution, i.e., more number of sections. Measurements done on an actual interleaved winding are presented to demonstrate feasibility of the proposed method.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124684593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
On-line partial discharge monitoring using MATLAB interface with DSO 局部放电在线监测用MATLAB与DSO接口
P. Ray, A. Maitra, A. Basuray
In this paper an approach based on wavelet transform to access the on line Partial Discharge (PD) signal using MATLAB interface with Digital Storage Oscilloscope (DSO) is proposed. The noisy signal is collected and fed to computer through DSO to de-noise this using wavelet threshold technique by selecting the optimal wavelet base. From the results it shows that the de-noising performance is satisfactory, even though the sampling rate of DSO is less, which is the main advantage of this method.
提出了一种基于小波变换的基于MATLAB接口的数字存储示波器(DSO)在线局部放电(PD)信号获取方法。噪声信号采集后通过DSO输入计算机,采用小波阈值技术选择最优小波基进行去噪。结果表明,尽管DSO的采样率较低,但该方法的降噪效果令人满意,这是该方法的主要优点。
{"title":"On-line partial discharge monitoring using MATLAB interface with DSO","authors":"P. Ray, A. Maitra, A. Basuray","doi":"10.1109/CATCON.2013.6737532","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737532","url":null,"abstract":"In this paper an approach based on wavelet transform to access the on line Partial Discharge (PD) signal using MATLAB interface with Digital Storage Oscilloscope (DSO) is proposed. The noisy signal is collected and fed to computer through DSO to de-noise this using wavelet threshold technique by selecting the optimal wavelet base. From the results it shows that the de-noising performance is satisfactory, even though the sampling rate of DSO is less, which is the main advantage of this method.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130606820","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Low cost RF sensor for partial discharge detection of high voltage apparatus 用于高压设备局部放电检测的低成本射频传感器
B. Sarkar, C. Koley, N. K. Roy, P. Kumbhakar
In-homogeneities, impurities, weakness within the insulating material or improper positioning of the electrode across insulator causes uneven electric field distribution into the localized area, which often creates partial discharge (PD) and are common mainly in high voltage power apparatus. After initiation of partial discharge into the localized region, it starts damaging the whole insulator with time. Thus detection of PD has become a major challenge for the researchers. This paper presents a method for design of low cost sensor for detection of PD, by detecting the radio frequency (RF) wave with the help of a patch antenna, which is simple and can be manufactured easily. A step by step approach has been described to develop the antenna for the detection of PD. Different analysis as required for the design parameter of the antenna has been simulated by ZELAND IE3D and presented in this paper. An experimental study has also been performed in the laboratory environment to validate the simulated results. The above study shows that, the indigenously made RF sensor is suitable to detect the partial discharge of a high voltage power apparatus and it is a cost effective tool in the field of online monitoring of partial discharge measurement.
不均匀性、杂质、绝缘材料的薄弱或电极在绝缘子上的不正确定位会导致局部区域的电场分布不均匀,这通常会产生局部放电(PD),主要见于高压电力设备中。局部放电进入局部区域后,随着时间的推移开始破坏整个绝缘子。因此,PD的检测已成为研究人员面临的主要挑战。本文提出了一种利用贴片天线检测射频波的低成本PD检测传感器的设计方法,该方法简单,易于制造。介绍了一种逐步研制PD检测天线的方法。本文利用ZELAND IE3D软件对天线的设计参数进行了仿真分析。在实验室环境下进行了实验研究,验证了模拟结果。上述研究表明,自主研制的射频传感器适用于高压电力设备局部放电的检测,是局部放电测量在线监测领域中一种经济有效的工具。
{"title":"Low cost RF sensor for partial discharge detection of high voltage apparatus","authors":"B. Sarkar, C. Koley, N. K. Roy, P. Kumbhakar","doi":"10.1109/CATCON.2013.6737509","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737509","url":null,"abstract":"In-homogeneities, impurities, weakness within the insulating material or improper positioning of the electrode across insulator causes uneven electric field distribution into the localized area, which often creates partial discharge (PD) and are common mainly in high voltage power apparatus. After initiation of partial discharge into the localized region, it starts damaging the whole insulator with time. Thus detection of PD has become a major challenge for the researchers. This paper presents a method for design of low cost sensor for detection of PD, by detecting the radio frequency (RF) wave with the help of a patch antenna, which is simple and can be manufactured easily. A step by step approach has been described to develop the antenna for the detection of PD. Different analysis as required for the design parameter of the antenna has been simulated by ZELAND IE3D and presented in this paper. An experimental study has also been performed in the laboratory environment to validate the simulated results. The above study shows that, the indigenously made RF sensor is suitable to detect the partial discharge of a high voltage power apparatus and it is a cost effective tool in the field of online monitoring of partial discharge measurement.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"150 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133918079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Detecting turn insulation failures in motor coils using ground current signals 利用接地电流信号检测电机线圈匝绝缘故障
A. El-Hag, A. Gaouda, S. Jayaram, S. Ul-Haq
This paper proposes a procedure for monitoring the status of the turn-to-turn insulation subjected to steep front impulse voltage using the line-to-ground leakage current as a signature. Medium voltage motor coils with rated voltage of 4kV are tested using steep front impulse voltages with rise time of 100ns. It has been found that the signature of the ground current is unique for a specific coil and it is voltage independent. Moreover, it has been observed that the recorded turn-to-ground current is more sensitive to turn-to-turn insulation damage than the applied impulse voltage waveform. Hence, by analyzing the line-to-ground leakage current the turn-to-turn insulation failures can be assessed.
本文提出了一种利用线路对地泄漏电流作为信号来监测受前冲击电压影响的匝间绝缘状态的方法。对额定电压为4kV的中压电机线圈,采用上升时间为100ns的陡前冲击电压进行试验。已经发现,对特定线圈来说,接地电流的特征是唯一的,并且与电压无关。此外,已经观察到记录的匝地电流对匝间绝缘损伤比施加的脉冲电压波形更敏感。因此,通过分析线路对地泄漏电流,可以评估匝间绝缘故障。
{"title":"Detecting turn insulation failures in motor coils using ground current signals","authors":"A. El-Hag, A. Gaouda, S. Jayaram, S. Ul-Haq","doi":"10.1109/CATCON.2013.6737536","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737536","url":null,"abstract":"This paper proposes a procedure for monitoring the status of the turn-to-turn insulation subjected to steep front impulse voltage using the line-to-ground leakage current as a signature. Medium voltage motor coils with rated voltage of 4kV are tested using steep front impulse voltages with rise time of 100ns. It has been found that the signature of the ground current is unique for a specific coil and it is voltage independent. Moreover, it has been observed that the recorded turn-to-ground current is more sensitive to turn-to-turn insulation damage than the applied impulse voltage waveform. Hence, by analyzing the line-to-ground leakage current the turn-to-turn insulation failures can be assessed.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131564661","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The effect of change in DC link series resistance on the AC/AC converter operation: Power converters embedded diagnostics 直流链路串联电阻变化对AC/AC变换器运行的影响:电源变换器嵌入式诊断
P. Lipnicki, M. Orkisz, D. Lewandowski, Adrian Tresch
Nowadays health and condition monitoring of the particular elements of the industrial system is a standard requirement. This also applies to power converters which are becoming more and more critical and important parts of the automation systems. That brings an important need for the appropriate solutions for internal diagnostics methods. One of the most important elements of the voltage source converter circuit is the DC capacitor(s). In many of the proposed and available methods the health state of the DC bus capacitor is described by monitoring the equivalent series resistance. This paper presents the method for monitoring the DC link capacitor aging effects. Additionally the article examines the possibility of using the emerging changes in the frequency spectrum of the converter currents for the DC link deterioration. The results are obtained from simulations.
如今,对工业系统中特定元件的健康和状态监测是一项标准要求。这也适用于日益成为自动化系统的关键和重要组成部分的电源转换器。这就需要为内部诊断方法提供适当的解决方案。直流电容是电压源变换器电路中最重要的元件之一。在许多提出的和可用的方法中,直流母线电容的健康状态是通过监测等效串联电阻来描述的。本文介绍了一种监测直流链路电容老化效应的方法。此外,本文还探讨了利用变换器电流频谱中出现的变化来处理直流链路劣化的可能性。通过仿真得到了结果。
{"title":"The effect of change in DC link series resistance on the AC/AC converter operation: Power converters embedded diagnostics","authors":"P. Lipnicki, M. Orkisz, D. Lewandowski, Adrian Tresch","doi":"10.1109/CATCON.2013.6737484","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737484","url":null,"abstract":"Nowadays health and condition monitoring of the particular elements of the industrial system is a standard requirement. This also applies to power converters which are becoming more and more critical and important parts of the automation systems. That brings an important need for the appropriate solutions for internal diagnostics methods. One of the most important elements of the voltage source converter circuit is the DC capacitor(s). In many of the proposed and available methods the health state of the DC bus capacitor is described by monitoring the equivalent series resistance. This paper presents the method for monitoring the DC link capacitor aging effects. Additionally the article examines the possibility of using the emerging changes in the frequency spectrum of the converter currents for the DC link deterioration. The results are obtained from simulations.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132722061","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Failure mode analysis of oil-free pulse capacitors 无油脉冲电容器失效模式分析
R. Sharma, Manohar A. Gurav, Satish G. Chavan
The failure mode analysis is conducted for the Oil-free (dry) Can-less pulse capacitors of 6kV working voltage. Pulse capacitor stability directly influences the dependability of the pulse power system, in which, capacitor located in. This capacitor is discharged in a low inductive circuit with sub-microsecond rise time of kA current peak pulse. Oil impregnated metal can capacitor delivers high power to the load. But use of these capacitors is limited due to high self inductance, higher weight, volume and oil leakage problems. Bi-axially oriented polypropylene (BOPP) film and aluminum foil with extended foil compact design oil-free capacitor delivers moderately high power, which comes closest to fulfilling the need. This paper describes the work done at High Voltage Laboratory in the field of oil-free pulse capacitors development and the analysis carried during development and testing of these capacitors. Which helps to improve the material, design, process, testing methods etc to develop an oil-free. Failure mode of the capacitors and some of the failed capacitors photographs are also presented.
对工作电压为6kV的无油(干)无罐脉冲电容器进行了失效模式分析。脉冲电容器的稳定性直接影响到脉冲电力系统的可靠性,其中,电容器位于。该电容器在低电感电路中放电,kA电流峰值脉冲上升时间为亚微秒。浸渍金属电容为负载提供高功率。但这些电容器的使用受到限制,由于高自感,较高的重量,体积和漏油问题。双轴定向聚丙烯(BOPP)薄膜和铝箔与扩展箔紧凑型设计无油电容器提供中等高的功率,这是最接近满足需要。本文介绍了高压实验室在无油脉冲电容器研制方面所做的工作以及在无油脉冲电容器研制和试验过程中所进行的分析。这有助于改进材料,设计,工艺,测试方法等,以发展无油。文中还介绍了电容器的失效模式和部分失效电容器的照片。
{"title":"Failure mode analysis of oil-free pulse capacitors","authors":"R. Sharma, Manohar A. Gurav, Satish G. Chavan","doi":"10.1109/CATCON.2013.6737490","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737490","url":null,"abstract":"The failure mode analysis is conducted for the Oil-free (dry) Can-less pulse capacitors of 6kV working voltage. Pulse capacitor stability directly influences the dependability of the pulse power system, in which, capacitor located in. This capacitor is discharged in a low inductive circuit with sub-microsecond rise time of kA current peak pulse. Oil impregnated metal can capacitor delivers high power to the load. But use of these capacitors is limited due to high self inductance, higher weight, volume and oil leakage problems. Bi-axially oriented polypropylene (BOPP) film and aluminum foil with extended foil compact design oil-free capacitor delivers moderately high power, which comes closest to fulfilling the need. This paper describes the work done at High Voltage Laboratory in the field of oil-free pulse capacitors development and the analysis carried during development and testing of these capacitors. Which helps to improve the material, design, process, testing methods etc to develop an oil-free. Failure mode of the capacitors and some of the failed capacitors photographs are also presented.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115767054","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Identification and classification of fault using S-transform in an unbalanced network 基于s变换的不平衡网络故障识别与分类
N. Roy, K. Bhattacharya
In this paper, S-Transform (ST) based fault classification rules are introduced in case of overhead transmission line. The power system model is simulated in MATLAB Simulink environment with unbalanced loading. The proposed technique requires voltage and current signals to be extracted at the sending and receiving end of the network. The current and voltage signals are processed by ST to produce complex S-matrices. Four types of features are obtained from the absolute value of S-matrix involving simple calculation and less computational time. It is noticed from the simulations that these features enjoy a valuable advantage to be a prime choice as parameters for detection of the type of fault and the affected phase on the basis of some threshold values. The classification rules based on these parameters have been established on the basis of 5220 simulations of fault conditions. The multiple fault conditions have been obtained by changing fault resistance, fault location and fault inception angle. The rules are also tested with signals impregnated by synthetic noise. The proposed scheme has been conveniently programmed in MATLAB and the output result is obtained fast and accurate. A computationally fast version of ST is intended to be implemented in future.
本文介绍了基于s变换的架空输电线路故障分类规则。在MATLAB Simulink环境下对负载不平衡的电力系统模型进行了仿真。该技术要求在网络的发送端和接收端提取电压和电流信号。电流和电压信号经ST处理后产生复杂的s矩阵。从s矩阵的绝对值得到四种特征,计算简单,计算时间短。仿真结果表明,这些特征可以作为基于某些阈值检测故障类型和影响相位的首选参数。在5220次故障工况模拟的基础上,建立了基于这些参数的分类规则。通过改变故障电阻、故障位置和故障起始角度,得到了多种故障条件。这些规则还用人工合成噪声信号进行了测试。该方案在MATLAB中编程方便,输出结果快速准确。一个计算速度快的ST版本打算在将来实现。
{"title":"Identification and classification of fault using S-transform in an unbalanced network","authors":"N. Roy, K. Bhattacharya","doi":"10.1109/CATCON.2013.6737482","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737482","url":null,"abstract":"In this paper, S-Transform (ST) based fault classification rules are introduced in case of overhead transmission line. The power system model is simulated in MATLAB Simulink environment with unbalanced loading. The proposed technique requires voltage and current signals to be extracted at the sending and receiving end of the network. The current and voltage signals are processed by ST to produce complex S-matrices. Four types of features are obtained from the absolute value of S-matrix involving simple calculation and less computational time. It is noticed from the simulations that these features enjoy a valuable advantage to be a prime choice as parameters for detection of the type of fault and the affected phase on the basis of some threshold values. The classification rules based on these parameters have been established on the basis of 5220 simulations of fault conditions. The multiple fault conditions have been obtained by changing fault resistance, fault location and fault inception angle. The rules are also tested with signals impregnated by synthetic noise. The proposed scheme has been conveniently programmed in MATLAB and the output result is obtained fast and accurate. A computationally fast version of ST is intended to be implemented in future.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114916609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Investigations on PD characteristics of vegetable oils for high voltage applications 高压植物油PD特性的研究
S. Banumathi, S. Chandrasekar, G. Montanari
Petroleum based mineral oils are mostly used for power apparatus insulation applications. They are not biodegradable and difficult to decompose the result of which has led to the development of vegetable based oils. Analysis of partial discharge characteristics of vegetable oil is very important, before suggesting it as an alternate to mineral oil for liquid insulation in high voltage apparatus. This paper deals with the analysis of partial discharge characteristics of extra virgin olive oil, castor oil and mineral oil. Partial discharge signals were measured with the help of an innovative PD detection system PDBASEII. The PRPD pattern, time domain and frequency domain characteristics of PD pulses of vegetable oils were measured and they were compared with the mineral oil. Preliminary results show that vegetable oils could be used as an alternate for mineral oils for high voltage insulation applications.
石油基矿物油主要用于电力设备绝缘。它们是不可生物降解和难以分解的,其结果导致了植物油的发展。在建议用植物油代替矿物油作为高压电器的液体绝缘材料之前,对植物油的局部放电特性进行分析是非常重要的。本文对特级初榨橄榄油、蓖麻油和矿物油的局部放电特性进行了分析。利用创新的PD检测系统PDBASEII对局部放电信号进行了测量。测定了植物油脉冲的PRPD模式、时域和频域特征,并与矿物油进行了比较。初步结果表明,植物油可作为矿物油的替代品用于高压绝缘。
{"title":"Investigations on PD characteristics of vegetable oils for high voltage applications","authors":"S. Banumathi, S. Chandrasekar, G. Montanari","doi":"10.1109/CATCON.2013.6737496","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737496","url":null,"abstract":"Petroleum based mineral oils are mostly used for power apparatus insulation applications. They are not biodegradable and difficult to decompose the result of which has led to the development of vegetable based oils. Analysis of partial discharge characteristics of vegetable oil is very important, before suggesting it as an alternate to mineral oil for liquid insulation in high voltage apparatus. This paper deals with the analysis of partial discharge characteristics of extra virgin olive oil, castor oil and mineral oil. Partial discharge signals were measured with the help of an innovative PD detection system PDBASEII. The PRPD pattern, time domain and frequency domain characteristics of PD pulses of vegetable oils were measured and they were compared with the mineral oil. Preliminary results show that vegetable oils could be used as an alternate for mineral oils for high voltage insulation applications.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123926713","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Wavelet and SFAM based classification of induction motor stator winding short circuit faults and incipient insulation failures 基于小波和sfm的异步电动机定子绕组短路故障和早期绝缘故障分类
S. Sarkar, S. Das, P. Purkait
Inter-turn fault in stator windings is one of the prime reasons behind a significant percentage of induction motor failures. Inter-turn short circuit fault may develop either due to complete failure of insulation between turns causing direct interturn short circuit fault or due to partial degradation of insulation between turns resulting in incipient insulation fault. Common protection schemes accompanied with induction motors in industrial applications normally fail to detect these faults especially when a minor number of turns are involved in such faults. Detection of these faults at their early stage can substantially reduce the possibilities of serious damage to the motor and consequently financial losses, environmental damage and probable personnel injury etc. Detection of such faults becomes a tricky task when these two different types of faults exhibit identical unbalance in motor supply currents. In the present study, two different series of experiments were carried out on an induction motor which was subjected to operate under direct short circuit fault and also under equivalent incipient insulation fault in stator winding. Using Extended Park's Vector Approach, Park's Vector Modulus (PVM) have been estimated from captured three phase current signals under different operating conditions of the motor. Several fault features were extracted from AC components present in PVMs by applying Continuous Wavelet Transform (CWT). Then, the fault features were fed to a Simplified Fuzzy Art-Map (SFAM) based classifier which has been found to perform accurately in identifying separately the direct inter-turn short circuit fault levels and equivalent incipient insulation failure conditions.
定子绕组匝间故障是感应电动机大量故障背后的主要原因之一。匝间绝缘完全失效导致直接匝间短路故障,或匝间绝缘部分退化导致初期绝缘故障,均可能发展为匝间短路故障。在工业应用中,常见的感应电动机保护方案通常无法检测到这些故障,特别是当此类故障涉及的匝数较少时。在早期阶段检测这些故障可以大大减少电动机严重损坏的可能性,从而减少经济损失、环境破坏和可能的人员伤害等。当这两种不同类型的故障在电机供电电流中表现出相同的不平衡时,检测此类故障成为一项棘手的任务。在本研究中,对异步电动机在直接短路故障和定子绕组等效初期绝缘故障下运行进行了两种不同系列的实验。利用扩展的Park矢量法,从捕获的电机在不同运行条件下的三相电流信号中估计出了Park矢量模量(PVM)。利用连续小波变换(CWT)对pvm中的交流分量进行故障特征提取。然后,将故障特征输入到基于简化模糊艺术映射(sfm)的分类器中,该分类器可以准确地分别识别直接匝间短路故障级别和等效绝缘初始故障条件。
{"title":"Wavelet and SFAM based classification of induction motor stator winding short circuit faults and incipient insulation failures","authors":"S. Sarkar, S. Das, P. Purkait","doi":"10.1109/CATCON.2013.6737505","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737505","url":null,"abstract":"Inter-turn fault in stator windings is one of the prime reasons behind a significant percentage of induction motor failures. Inter-turn short circuit fault may develop either due to complete failure of insulation between turns causing direct interturn short circuit fault or due to partial degradation of insulation between turns resulting in incipient insulation fault. Common protection schemes accompanied with induction motors in industrial applications normally fail to detect these faults especially when a minor number of turns are involved in such faults. Detection of these faults at their early stage can substantially reduce the possibilities of serious damage to the motor and consequently financial losses, environmental damage and probable personnel injury etc. Detection of such faults becomes a tricky task when these two different types of faults exhibit identical unbalance in motor supply currents. In the present study, two different series of experiments were carried out on an induction motor which was subjected to operate under direct short circuit fault and also under equivalent incipient insulation fault in stator winding. Using Extended Park's Vector Approach, Park's Vector Modulus (PVM) have been estimated from captured three phase current signals under different operating conditions of the motor. Several fault features were extracted from AC components present in PVMs by applying Continuous Wavelet Transform (CWT). Then, the fault features were fed to a Simplified Fuzzy Art-Map (SFAM) based classifier which has been found to perform accurately in identifying separately the direct inter-turn short circuit fault levels and equivalent incipient insulation failure conditions.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122350218","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Cross Hilbert-Huang transform based feature extraction method for multiple PQ disturbance classification 基于交叉Hilbert-Huang变换的多PQ扰动分类特征提取方法
S. Dalai, D. Dey, B. Chatterjee, S. Chakravorti, K. Bhattacharya
This paper presents a new methodology of Cross-Hilbert Huang transform based feature selection for sensing simultaneous occurrence of multiple power quality disturbances. Kernel PCA is used for feature selection because this method is well suited for non-linear and non-stationary multiple power quality disturbances. A linear support vector machine is used for classification of the extracted features. Results show that the performance is comparable with the results reported in the literatures. The present method is generic in nature and can be applicable for topologically similar problems.
提出了一种基于Cross-Hilbert Huang变换的特征选择方法,用于检测多种电能质量扰动的同时发生。核主成分分析用于特征选择,因为该方法很适合于非线性和非平稳的多重电能质量干扰。利用线性支持向量机对提取的特征进行分类。结果表明,该方法的性能与文献报道的结果相当。本方法具有通用性,可适用于拓扑相似的问题。
{"title":"Cross Hilbert-Huang transform based feature extraction method for multiple PQ disturbance classification","authors":"S. Dalai, D. Dey, B. Chatterjee, S. Chakravorti, K. Bhattacharya","doi":"10.1109/CATCON.2013.6737519","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737519","url":null,"abstract":"This paper presents a new methodology of Cross-Hilbert Huang transform based feature selection for sensing simultaneous occurrence of multiple power quality disturbances. Kernel PCA is used for feature selection because this method is well suited for non-linear and non-stationary multiple power quality disturbances. A linear support vector machine is used for classification of the extracted features. Results show that the performance is comparable with the results reported in the literatures. The present method is generic in nature and can be applicable for topologically similar problems.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"223 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133938177","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
期刊
2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1