The Effect of Electrospun PMMA/rGO Fiber Addition on the Improvement of the Physical and Mechanical Properties of PMMA Resin 静电纺PMMA/rGO纤维的加入对PMMA树脂物理力学性能改善的影响
Pub Date : 2025-07-04 DOI: 10.3390/prosthesis7040079
Tuğçe Gül ELMAS ALSINI, Işın Kürkçüoğlu, Neslihan Nohut Maşlakcı, Ayşegül Uygun Öksüz
Background/Objectives: Autopolymerizing poly (methyl methacrylate) (PMMA) resin is widely used in provisional restorations; however, its inadequate mechanical properties represent a significant limitation. This study aimed to develop electrospun fibers with chemically reduced graphene oxide (rGO) and to evaluate the effect of fiber reinforcement on the mechanical and physical properties of a commercially available PMMA resin. Methods: Electrospinning was employed to produce nanofibers containing 0.02 wt% and 0.05 wt% rGO within a PMMA matrix. Fiber characterization was performed using SEM-EDS, XRD, TGA/DTG, and FTIR. Following characterization, the fibers were blended into PMMA resin at 1%, 2.5%, and 5% (by weight). The resulting fiber-reinforced composites were tested for flexural strength, elastic modulus, surface roughness, and Vickers microhardness. Results: The addition of 1% and 2.5% PMMA/rGO-0.02 fibers and 1% PMMA/rGO-0.05 fibers significantly improved the flexural strength of PMMA compared with the control group (p < 0.05). A statistically significant increase in elastic modulus was observed only in the group containing 1% PMMA/rGO-0.02 fibers (p < 0.05). However, there were no significant differences in surface roughness or microhardness between the control and experimental groups (p > 0.05). Conclusions: Incorporating electrospun PMMA-rGO fibers into PMMA resin enhances flexural properties at low concentrations without altering surface characteristics. These findings suggest that such fiber-reinforced systems hold promises for improving the mechanical performance and functional longevity of provisional dental restorations under clinical conditions.
背景/目的:自聚合聚甲基丙烯酸甲酯(PMMA)树脂广泛应用于临时修复;然而,它不充分的机械性能是一个重大的限制。本研究旨在开发含有化学还原氧化石墨烯(rGO)的静电纺丝纤维,并评估纤维增强对市售PMMA树脂的机械和物理性能的影响。方法:采用静电纺丝法在PMMA基体中制备含有0.02 wt%和0.05 wt%氧化石墨烯的纳米纤维。采用SEM-EDS、XRD、TGA/DTG和FTIR对纤维进行了表征。表征完成后,将纤维以1%、2.5%和5%(重量比)的比例掺入PMMA树脂中。测试了所得纤维增强复合材料的抗弯强度、弹性模量、表面粗糙度和维氏显微硬度。结果:与对照组相比,添加1%、2.5% PMMA/rGO-0.02纤维和1% PMMA/rGO-0.05纤维可显著提高PMMA的抗弯强度(p < 0.05)。只有在含有1% PMMA/rGO-0.02纤维的组中,弹性模量有统计学意义的增加(p < 0.05)。然而,对照组和试验组在表面粗糙度和显微硬度方面没有显著差异(p > 0.05)。结论:将静电纺PMMA- rgo纤维掺入PMMA树脂中,可以在不改变表面特性的情况下提高低浓度PMMA树脂的弯曲性能。这些发现表明,在临床条件下,这种纤维增强系统有望改善临时牙科修复体的机械性能和功能寿命。
{"title":"The Effect of Electrospun PMMA/rGO Fiber Addition on the Improvement of the Physical and Mechanical Properties of PMMA Resin","authors":"Tuğçe Gül ELMAS ALSINI, Işın Kürkçüoğlu, Neslihan Nohut Maşlakcı, Ayşegül Uygun Öksüz","doi":"10.3390/prosthesis7040079","DOIUrl":"https://doi.org/10.3390/prosthesis7040079","url":null,"abstract":"Background/Objectives: Autopolymerizing poly (methyl methacrylate) (PMMA) resin is widely used in provisional restorations; however, its inadequate mechanical properties represent a significant limitation. This study aimed to develop electrospun fibers with chemically reduced graphene oxide (rGO) and to evaluate the effect of fiber reinforcement on the mechanical and physical properties of a commercially available PMMA resin. Methods: Electrospinning was employed to produce nanofibers containing 0.02 wt% and 0.05 wt% rGO within a PMMA matrix. Fiber characterization was performed using SEM-EDS, XRD, TGA/DTG, and FTIR. Following characterization, the fibers were blended into PMMA resin at 1%, 2.5%, and 5% (by weight). The resulting fiber-reinforced composites were tested for flexural strength, elastic modulus, surface roughness, and Vickers microhardness. Results: The addition of 1% and 2.5% PMMA/rGO-0.02 fibers and 1% PMMA/rGO-0.05 fibers significantly improved the flexural strength of PMMA compared with the control group (p &lt; 0.05). A statistically significant increase in elastic modulus was observed only in the group containing 1% PMMA/rGO-0.02 fibers (p &lt; 0.05). However, there were no significant differences in surface roughness or microhardness between the control and experimental groups (p &gt; 0.05). Conclusions: Incorporating electrospun PMMA-rGO fibers into PMMA resin enhances flexural properties at low concentrations without altering surface characteristics. These findings suggest that such fiber-reinforced systems hold promises for improving the mechanical performance and functional longevity of provisional dental restorations under clinical conditions.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"7 4","pages":"79-79"},"PeriodicalIF":0.0,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147890308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Biomechanical Factors in the Prognosis of Implants: A Clinical Study 植入物预后的生物力学因素:临床研究
Pub Date : 2024-08-09 DOI: 10.3390/prosthesis6040065
Paola Ceresuela, Javier Montero
This study aims to assess the impact of occlusal loadings on peri-implant bone loss by measuring the cantilever of each implant and evaluating the occlusal pattern using PRESCALE® and to examine the relationship between occlusal overload and peri-implant bone loss, including marginal bone loss (MBL) and biomechanical factors, in a sample of 41 patients with a total of 135 implants. In addition, this study examines the influence of occlusal overload among patient groups with no marginal bone loss, unilateral bone loss, and bilateral bone loss. The PRESCALE® quantifies the occlusal area and load along the dental arch. The analysis of variance (ANOVA) was used for comparing quantitative variables between groups and the Pearson correlation coefficient (r) was applied to analyze linear relationships between quantitative variables. The results of occlusal distribution and pressure range were presented using the PRESCALE®. It was found that the mesial cantilever was statistically significantly greater (p < 0.05) for the bilateral bone loss group. Additionally, MBL was significantly proportional to occlusal loading in the left anterior sector (r = 0.47; p < 0.01) and to follow-up time (r = 0.29; p < 0.01), though it was also proportional to implant diameter and length (r = 0.27 and r = 0.20). The presence of a wider cantilever and excess occlusal loading appears to be associated with increased bone loss.
本研究的目的是通过使用 PRESCALE® 测量每个种植体的悬臂和评估咬合模式,评估咬合负荷对种植体周围骨质流失的影响,并以 41 名患者共 135 个种植体为样本,研究咬合超负荷与种植体周围骨质流失(包括边缘骨质流失 (MBL) 和生物力学因素)之间的关系。此外,该研究还探讨了咬合超负荷对无边缘骨缺失、单侧骨缺失和双侧骨缺失患者群体的影响。PRESCALE® 可以量化牙弓的咬合面积和负荷。方差分析(ANOVA)用于比较各组之间的定量变量,皮尔逊相关系数(r)用于分析定量变量之间的线性关系。使用 PRESCALE® 显示咬合分布和压力范围的结果。结果发现,双侧骨质流失组的中悬臂在统计学上明显更大(P < 0.05)。此外,MBL 与左前区的咬合负荷(r = 0.47;p < 0.01)和随访时间(r = 0.29;p < 0.01)成显著正比,但也与种植体直径和长度(r = 0.27 和 r = 0.20)成正比。悬臂较宽和咬合负荷过重似乎与骨质流失增加有关。
{"title":"Biomechanical Factors in the Prognosis of Implants: A Clinical Study","authors":"Paola Ceresuela, Javier Montero","doi":"10.3390/prosthesis6040065","DOIUrl":"https://doi.org/10.3390/prosthesis6040065","url":null,"abstract":"This study aims to assess the impact of occlusal loadings on peri-implant bone loss by measuring the cantilever of each implant and evaluating the occlusal pattern using PRESCALE® and to examine the relationship between occlusal overload and peri-implant bone loss, including marginal bone loss (MBL) and biomechanical factors, in a sample of 41 patients with a total of 135 implants. In addition, this study examines the influence of occlusal overload among patient groups with no marginal bone loss, unilateral bone loss, and bilateral bone loss. The PRESCALE® quantifies the occlusal area and load along the dental arch. The analysis of variance (ANOVA) was used for comparing quantitative variables between groups and the Pearson correlation coefficient (r) was applied to analyze linear relationships between quantitative variables. The results of occlusal distribution and pressure range were presented using the PRESCALE®. It was found that the mesial cantilever was statistically significantly greater (p < 0.05) for the bilateral bone loss group. Additionally, MBL was significantly proportional to occlusal loading in the left anterior sector (r = 0.47; p < 0.01) and to follow-up time (r = 0.29; p < 0.01), though it was also proportional to implant diameter and length (r = 0.27 and r = 0.20). The presence of a wider cantilever and excess occlusal loading appears to be associated with increased bone loss.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"30 33","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141924759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Current Progress in the Development of Resin Materials with Nanofillers for 3D Printing of Denture Base 含纳米填料的树脂材料在义齿基托三维打印领域的最新进展
Pub Date : 2024-07-16 DOI: 10.3390/prosthesis6040055
Ahmed Altarazi, J. Haider, Abdulaziz Alhotan, N. Silikas, Hugh Devlin
Background: Advanced manufacturing techniques, such as three-dimensional (3D) printing, use digital models from computer-aided design to produce 3D objects. They are frequently employed in different areas of dentistry, such as orthodontics, oral implantology, and prosthodontics. Purpose: The aim of this review was to provide a comprehensive overview of 3D-printing technology for denture bases and explore the influence of incorporating different fillers into 3D-printed denture base resins on their physical, mechanical, and biological characteristics. Methods: Relevant studies were identified by searching papers published between 2010 and 2023 in several online databases, such as Scopus, PubMed, Cochrane library, and Google Scholar. The main inclusion criteria used during the search was identifying the papers which added nanoparticles in the resin as an agent to bring different functional characteristics within the 3D-printed denture base resin. Furthermore, even though the search criteria were set for finding papers from the past 10 years, development in this field has accelerated in the past 4–5 years. Findings: Various fillers have exhibited promising results in terms of their ability to improve the functional properties of the 3D-printed denture base resins. However, such improvements come at a higher cost with careful resin preparation when considering the filler particles, the fabrication complexities and the extensive post-processing that is required. Conclusions: The use of 3D-printing approaches and fillers to fabricate dentures is associated with significant benefits in terms of imparting functional properties, consistency in fabrication and opportunities for innovation. However, further research is required to acquire a better understanding of the holistic, long-term performance of various filler materials, concentrations, their clinical relevance and particularly the potential health risks from the fillers.
背景:三维(3D)打印等先进制造技术使用计算机辅助设计的数字模型来制造三维物体。它们经常被用于牙科的不同领域,如牙齿矫正、口腔种植和修复。目的:本综述旨在全面概述义齿基托的三维打印技术,并探讨在三维打印义齿基托树脂中加入不同填料对其物理、机械和生物特性的影响。研究方法通过在 Scopus、PubMed、Cochrane library 和 Google Scholar 等多个在线数据库中搜索 2010 年至 2023 年间发表的论文,确定相关研究。搜索过程中使用的主要纳入标准是识别在树脂中添加纳米粒子作为制剂,从而为 3D 打印义齿基底树脂带来不同功能特性的论文。此外,尽管搜索标准设定为查找过去 10 年内的论文,但该领域在过去 4-5 年内的发展速度有所加快。研究结果各种填料在改善 3D 打印义齿基底树脂的功能特性方面取得了可喜的成果。然而,考虑到填料颗粒、制造的复杂性和所需的大量后处理,这些改进需要以较高的成本进行精心的树脂制备。结论:使用三维打印方法和填充物制作假牙在赋予功能特性、制作一致性和创新机会方面具有显著优势。然而,要更好地了解各种填充材料的整体和长期性能、浓度、临床相关性,特别是填充物的潜在健康风险,还需要进一步的研究。
{"title":"Current Progress in the Development of Resin Materials with Nanofillers for 3D Printing of Denture Base","authors":"Ahmed Altarazi, J. Haider, Abdulaziz Alhotan, N. Silikas, Hugh Devlin","doi":"10.3390/prosthesis6040055","DOIUrl":"https://doi.org/10.3390/prosthesis6040055","url":null,"abstract":"Background: Advanced manufacturing techniques, such as three-dimensional (3D) printing, use digital models from computer-aided design to produce 3D objects. They are frequently employed in different areas of dentistry, such as orthodontics, oral implantology, and prosthodontics. Purpose: The aim of this review was to provide a comprehensive overview of 3D-printing technology for denture bases and explore the influence of incorporating different fillers into 3D-printed denture base resins on their physical, mechanical, and biological characteristics. Methods: Relevant studies were identified by searching papers published between 2010 and 2023 in several online databases, such as Scopus, PubMed, Cochrane library, and Google Scholar. The main inclusion criteria used during the search was identifying the papers which added nanoparticles in the resin as an agent to bring different functional characteristics within the 3D-printed denture base resin. Furthermore, even though the search criteria were set for finding papers from the past 10 years, development in this field has accelerated in the past 4–5 years. Findings: Various fillers have exhibited promising results in terms of their ability to improve the functional properties of the 3D-printed denture base resins. However, such improvements come at a higher cost with careful resin preparation when considering the filler particles, the fabrication complexities and the extensive post-processing that is required. Conclusions: The use of 3D-printing approaches and fillers to fabricate dentures is associated with significant benefits in terms of imparting functional properties, consistency in fabrication and opportunities for innovation. However, further research is required to acquire a better understanding of the holistic, long-term performance of various filler materials, concentrations, their clinical relevance and particularly the potential health risks from the fillers.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"42 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141643593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Magnetic Resonance Imaging in Digital Dentistry: The Start of a New Era 数字牙科中的磁共振成像:新时代的开始
Pub Date : 2024-07-16 DOI: 10.3390/prosthesis6040056
G. Spagnuolo, Parisa Soltani
In June 2024, at the European Congress of Dentomaxillofacial Radiology (ECDMFR) in Germany, the first-ever magnetic resonance imaging (MRI) system dedicated to dentistry was introduced [...]
2024 年 6 月,在德国举行的欧洲牙颌面放射学大会(ECDMFR)上,首次推出了牙科专用磁共振成像(MRI)系统 [...]
{"title":"Magnetic Resonance Imaging in Digital Dentistry: The Start of a New Era","authors":"G. Spagnuolo, Parisa Soltani","doi":"10.3390/prosthesis6040056","DOIUrl":"https://doi.org/10.3390/prosthesis6040056","url":null,"abstract":"In June 2024, at the European Congress of Dentomaxillofacial Radiology (ECDMFR) in Germany, the first-ever magnetic resonance imaging (MRI) system dedicated to dentistry was introduced [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"4 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141640935","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Artificial Intelligence in Reconstructive Implant Dentistry—Current Perspectives 人工智能在修复种植牙学中的应用--当前视角
Pub Date : 2024-07-15 DOI: 10.3390/prosthesis6040054
K. I. Afrashtehfar, Moosa Abuzayeda, Colin Alexander Murray
In recent years, artificial intelligence (AI) has emerged as a transformative force in reconstructive implant dentistry [...]
近年来,人工智能(AI)已成为重建种植牙领域的一股变革力量 [...]
{"title":"Artificial Intelligence in Reconstructive Implant Dentistry—Current Perspectives","authors":"K. I. Afrashtehfar, Moosa Abuzayeda, Colin Alexander Murray","doi":"10.3390/prosthesis6040054","DOIUrl":"https://doi.org/10.3390/prosthesis6040054","url":null,"abstract":"In recent years, artificial intelligence (AI) has emerged as a transformative force in reconstructive implant dentistry [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"22 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141648051","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Effect of the Incorporation of a 3D-Printed Titanium Framework on the Mechanical Properties CAD/CAM Denture Base Materials 三维打印钛框架对 CAD/CAM 义齿基托材料机械性能的影响
Pub Date : 2024-07-10 DOI: 10.3390/prosthesis6040053
R. Delgado-Ruiz, Ido Brintouch, Aisha Ali, Yiwei Fang, George E Romanos, Miriam Rafailovich
Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate (PMMA)-based materials. These methods have served well for many years. More recently, the incorporation of computer-aided design and computer-aided manufacturing (CAD/CAM) to fabricate complete dentures has been shown to enhance the dentures’ mechanical properties, including resistance to wear and impact strength. This study aims to investigate the mechanical properties and fracture types of CAD/CAM denture base materials (both milled and printed) as compared to a novel proprietary method that embeds a 3D-printed framework within PMMA-milled blocks. The null hypothesis is that incorporating a 3D-printed framework does not affect the mechanical properties of milled PMMA blocks. Methods: Three groups of bars were fabricated using CAD/CAM methods: printed (P), milled (M), and milled with a 3D-printed metallic framework reinforcement (M + F). A three-point bending test evaluated deformation, followed by an impact fracture test for fracture toughness. A descriptive fractographic analysis assessed the fracture characteristics. A statistical analysis using a paired t-test compared the differences between the groups. Results: The P group showed more elastic deformation than the M and M + F groups (p < 0.05). The M + F group achieved a higher fracture toughness as compared to the M and P groups (p < 0.05). Conclusions: Within the limitations of this experimental study, the null hypothesis can be rejected. Milled samples with an embedded 3D-printed titanium framework possess higher resistance to impact than milled samples without frameworks, and printed samples and milled samples with embedded 3d-printed titanium frameworks present increased flexural strength and lower elastic deformation as compared to milled samples without frameworks and printed samples.
背景:全口义齿应能承受咬合力和磨损。然而,随着时间的推移,假牙会出现疲劳、裂缝、崩裂和断裂。制作全口义齿的传统方法包括注射成型、热固化以及使用微波处理聚甲基丙烯酸甲酯(PMMA)材料。这些方法多年来一直行之有效。最近,计算机辅助设计和计算机辅助制造(CAD/CAM)技术被用于制造全口义齿,已被证明可以提高义齿的机械性能,包括耐磨性和抗冲击强度。本研究旨在研究 CAD/CAM 义齿基托材料(包括铣制和打印)的机械性能和断裂类型,并将其与在 PMMA 铣制块中嵌入 3D 打印框架的新型专有方法进行比较。零假设是嵌入三维打印框架不会影响磨制 PMMA 块的机械性能。方法:使用 CAD/CAM 方法制造了三组棒材:打印(P)、铣削(M)和铣削加三维打印金属框架加固(M + F)。三点弯曲测试评估了变形情况,随后进行了冲击断裂测试以评估断裂韧性。描述性断裂分析评估了断裂特征。使用配对 t 检验进行统计分析,比较组间差异。结果显示P 组比 M 组和 M + F 组显示出更大的弹性变形(p < 0.05)。与 M 组和 P 组相比,M + F 组的断裂韧性更高(P < 0.05)。结论:在本实验研究的限制条件下,可以拒绝零假设。与不带框架的磨制样品相比,带有嵌入式三维打印钛框架的磨制样品具有更高的抗冲击性,与不带框架的磨制样品和打印样品相比,带有嵌入式三维打印钛框架的打印样品和磨制样品具有更高的抗弯强度和更低的弹性变形。
{"title":"The Effect of the Incorporation of a 3D-Printed Titanium Framework on the Mechanical Properties CAD/CAM Denture Base Materials","authors":"R. Delgado-Ruiz, Ido Brintouch, Aisha Ali, Yiwei Fang, George E Romanos, Miriam Rafailovich","doi":"10.3390/prosthesis6040053","DOIUrl":"https://doi.org/10.3390/prosthesis6040053","url":null,"abstract":"Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate (PMMA)-based materials. These methods have served well for many years. More recently, the incorporation of computer-aided design and computer-aided manufacturing (CAD/CAM) to fabricate complete dentures has been shown to enhance the dentures’ mechanical properties, including resistance to wear and impact strength. This study aims to investigate the mechanical properties and fracture types of CAD/CAM denture base materials (both milled and printed) as compared to a novel proprietary method that embeds a 3D-printed framework within PMMA-milled blocks. The null hypothesis is that incorporating a 3D-printed framework does not affect the mechanical properties of milled PMMA blocks. Methods: Three groups of bars were fabricated using CAD/CAM methods: printed (P), milled (M), and milled with a 3D-printed metallic framework reinforcement (M + F). A three-point bending test evaluated deformation, followed by an impact fracture test for fracture toughness. A descriptive fractographic analysis assessed the fracture characteristics. A statistical analysis using a paired t-test compared the differences between the groups. Results: The P group showed more elastic deformation than the M and M + F groups (p < 0.05). The M + F group achieved a higher fracture toughness as compared to the M and P groups (p < 0.05). Conclusions: Within the limitations of this experimental study, the null hypothesis can be rejected. Milled samples with an embedded 3D-printed titanium framework possess higher resistance to impact than milled samples without frameworks, and printed samples and milled samples with embedded 3d-printed titanium frameworks present increased flexural strength and lower elastic deformation as compared to milled samples without frameworks and printed samples.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"2 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141658752","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determinants of Temperature Development during Dental Implant Surgery 种植牙手术过程中温度变化的决定因素
Pub Date : 2024-06-12 DOI: 10.3390/prosthesis6030046
Kirsten Sekura, Carolin Erbel, Matthias Karl, T. Grobecker-Karl
Mechanical and thermal trauma during implant surgery may be reasons for initial peri-implant bone loss. Temperature development during drilling and implant insertion were quantified in this series of in vitro and animal experiments. Polyurethane foam material mimicking different classes of alveolar bone was used as a model material for simulating implant surgery. Using thermocouples, temperature development was determined in the model material at depths of 3 mm and 10 mm during site preparation and implant insertion. Additionally, an infrared camera allowed for measuring drill temperatures both in vitro and as part of an animal trial using an intraoral minipig model. Drill diameter and repeated usage of drills did not have a major effect on temperature generation. The addition of a diamond-like carbon coating, bone density, predrilling, and irrigation heavily affected intraosseous temperatures. In vivo, applying regular drill protocols, an intraosseous temperature rise of approximately 3 °K was determined. Implant geometry as well as the amount of undersizing of an osteotomy governed heat generation during implant insertion. Drill protocols and the amount of undersizing of an implant osteotomy constitute parameters by which clinicians can limit trauma during implant surgery.
种植手术过程中的机械和热创伤可能是导致初期种植体周围骨质流失的原因。在这一系列体外和动物实验中,对钻孔和种植体植入过程中的温度变化进行了量化。模拟不同类型牙槽骨的聚氨酯泡沫材料被用作模拟种植手术的模型材料。使用热电偶测定了模型材料在部位准备和种植体植入过程中 3 毫米和 10 毫米深度的温度变化。此外,红外线相机还可以测量体外钻的温度,以及口内迷你猪模型的动物试验温度。钻头直径和钻头的重复使用对温度的产生影响不大。而添加类金刚石碳涂层、骨密度、预钻孔和灌洗则会严重影响骨内温度。在体内,采用常规的钻孔方案,可确定骨内温度升高约 3 °K。种植体的几何形状以及截骨不足的程度会影响种植体植入时的发热量。钻孔方案和种植体截骨不足量是临床医生在种植手术中限制创伤的参数。
{"title":"Determinants of Temperature Development during Dental Implant Surgery","authors":"Kirsten Sekura, Carolin Erbel, Matthias Karl, T. Grobecker-Karl","doi":"10.3390/prosthesis6030046","DOIUrl":"https://doi.org/10.3390/prosthesis6030046","url":null,"abstract":"Mechanical and thermal trauma during implant surgery may be reasons for initial peri-implant bone loss. Temperature development during drilling and implant insertion were quantified in this series of in vitro and animal experiments. Polyurethane foam material mimicking different classes of alveolar bone was used as a model material for simulating implant surgery. Using thermocouples, temperature development was determined in the model material at depths of 3 mm and 10 mm during site preparation and implant insertion. Additionally, an infrared camera allowed for measuring drill temperatures both in vitro and as part of an animal trial using an intraoral minipig model. Drill diameter and repeated usage of drills did not have a major effect on temperature generation. The addition of a diamond-like carbon coating, bone density, predrilling, and irrigation heavily affected intraosseous temperatures. In vivo, applying regular drill protocols, an intraosseous temperature rise of approximately 3 °K was determined. Implant geometry as well as the amount of undersizing of an osteotomy governed heat generation during implant insertion. Drill protocols and the amount of undersizing of an implant osteotomy constitute parameters by which clinicians can limit trauma during implant surgery.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"120 28","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141351901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Neuroprosthetics of the Hand: Current Hot Research Topics, Research Trends and Challenges, and Recent Innovations 手部神经义肢:当前热门研究课题、研究趋势和挑战以及最新创新成果
Pub Date : 2024-06-12 DOI: 10.3390/prosthesis6030047
A. Otte
If you want to buy a new car today, you can expect a flood of digital features and assistance systems that initially make the analog human heart beat faster [...]
如果您今天想购买一辆新车,您可以期待大量的数字功能和辅助系统,这些功能和系统最初会让模拟人心跳加速 [...]
{"title":"Neuroprosthetics of the Hand: Current Hot Research Topics, Research Trends and Challenges, and Recent Innovations","authors":"A. Otte","doi":"10.3390/prosthesis6030047","DOIUrl":"https://doi.org/10.3390/prosthesis6030047","url":null,"abstract":"If you want to buy a new car today, you can expect a flood of digital features and assistance systems that initially make the analog human heart beat faster [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"129 16","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141351489","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
MES-FES Interface Enhances Quadriceps Muscle Response in Sitting Position in Incomplete Spinal Cord Injury: Pilot Study MES-FES 界面增强不完全脊髓损伤患者坐位时股四头肌的反应:试点研究
Pub Date : 2024-06-11 DOI: 10.3390/prosthesis6030045
Denise Bolonhezi Ribeiro, L. Sartori, María Verónica González Méndez, Roger Burgo de Souza, Daniel Prado Campos, Paulo Broniera Júnior, José J. A. Mendes Junior, Eddy Krueger
Purpose: In incomplete spinal cord injury (SCI), there is a partial decrease in motor or sensory or autonomic function. Mainly due to the motor impairment in SCI, a muscle–machine interface is a tool that can bring functional benefits to this population. Objective: To investigate the feasibility of the non-invasive myoelectric signal–functional electrical stimulation (MES-FES) interface on the response of the quadriceps muscle in an individual with incomplete SCI. Methods: This is a quasi-experimental, uncontrolled, longitudinal case report study carried out with an individual with incomplete SCI in the chronic phase. The assessments performed before (pre) and after eight (post8) interventions were neuromuscular assessment (surface electromyography (EMG) in rectus femoris (RF) and vastus lateralis (VL) muscles); muscle strength (load cell); knee extension range of motion (goniometry); spasticity (Modified Ashworth Scale); and quality of life (Spinal Cord Injury Quality-of-Life Questionnaire (SCI-QoL.Br)). The MES-FES interface was associated with physical therapy exercises on the extension knee joint muscle group. Results: Improvement in neuromuscular activation (normalized increase in EMGRMS of 2% (RF) and 3.3% (VL)) and synchronism of the motor units (normalized reduction in EMGMDF of 22.8% (RF) and 5.9% (VL)); 1.4 kgf increase in quadriceps strength; 10.6° increase in knee joint extension amplitude; 1 point spasticity reduction; improved quality of life, confirmed by a 12-point reduction in the SCI-QoL.Br score. Moreover, along with interventions, the participant increased the correct FES activation rate, indicating a user learning curve (ρ = 0.78, p-value = 0.04). Conclusions: The MES-FES interface associated with physical therapy promotes neuromuscular and quality of life improvements in the SCI participant.
目的:不完全脊髓损伤(SCI)患者的运动、感觉或自主神经功能会部分减退。主要由于 SCI 患者的运动功能障碍,肌肉-机械接口是一种能为这类人群带来功能性益处的工具。研究目的研究无创肌电信号-功能性电刺激(MES-FES)接口对不完全性 SCI 患者股四头肌反应的可行性。方法:这是一项准实验性、非对照、纵向病例报告研究,研究对象是一名处于慢性期的不完全性 SCI 患者。在八次干预前(pre)和干预后(post8)进行的评估包括神经肌肉评估(股直肌(RF)和股外侧肌(VL)的表面肌电图(EMG))、肌肉力量(称重传感器)、膝关节伸展活动范围(动态关节角度计)、痉挛(修正的阿什沃斯量表)和生活质量(脊髓损伤生活质量问卷(SCI-QoL.Br))。MES-FES 界面与伸展膝关节肌群的物理治疗练习相关联。结果改善了神经肌肉激活(EMGRMS 正常化增加 2%(RF)和 3.3%(VL))和运动单元的同步性(EMGMDF 正常化减少 22.8%(RF)和 5.9%(VL));股四头肌力量增加 1.4 kgf;膝关节伸展幅度增加 10.6°;痉挛减少 1 点;生活质量得到改善,SCI-QoL.Br 分数减少 12 点证实了这一点。此外,在采取干预措施的同时,参与者还提高了正确的 FES 激活率,这表明存在用户学习曲线(ρ = 0.78,p 值 = 0.04)。结论结合物理治疗的 MES-FES 界面可促进改善 SCI 参与者的神经肌肉和生活质量。
{"title":"MES-FES Interface Enhances Quadriceps Muscle Response in Sitting Position in Incomplete Spinal Cord Injury: Pilot Study","authors":"Denise Bolonhezi Ribeiro, L. Sartori, María Verónica González Méndez, Roger Burgo de Souza, Daniel Prado Campos, Paulo Broniera Júnior, José J. A. Mendes Junior, Eddy Krueger","doi":"10.3390/prosthesis6030045","DOIUrl":"https://doi.org/10.3390/prosthesis6030045","url":null,"abstract":"Purpose: In incomplete spinal cord injury (SCI), there is a partial decrease in motor or sensory or autonomic function. Mainly due to the motor impairment in SCI, a muscle–machine interface is a tool that can bring functional benefits to this population. Objective: To investigate the feasibility of the non-invasive myoelectric signal–functional electrical stimulation (MES-FES) interface on the response of the quadriceps muscle in an individual with incomplete SCI. Methods: This is a quasi-experimental, uncontrolled, longitudinal case report study carried out with an individual with incomplete SCI in the chronic phase. The assessments performed before (pre) and after eight (post8) interventions were neuromuscular assessment (surface electromyography (EMG) in rectus femoris (RF) and vastus lateralis (VL) muscles); muscle strength (load cell); knee extension range of motion (goniometry); spasticity (Modified Ashworth Scale); and quality of life (Spinal Cord Injury Quality-of-Life Questionnaire (SCI-QoL.Br)). The MES-FES interface was associated with physical therapy exercises on the extension knee joint muscle group. Results: Improvement in neuromuscular activation (normalized increase in EMGRMS of 2% (RF) and 3.3% (VL)) and synchronism of the motor units (normalized reduction in EMGMDF of 22.8% (RF) and 5.9% (VL)); 1.4 kgf increase in quadriceps strength; 10.6° increase in knee joint extension amplitude; 1 point spasticity reduction; improved quality of life, confirmed by a 12-point reduction in the SCI-QoL.Br score. Moreover, along with interventions, the participant increased the correct FES activation rate, indicating a user learning curve (ρ = 0.78, p-value = 0.04). Conclusions: The MES-FES interface associated with physical therapy promotes neuromuscular and quality of life improvements in the SCI participant.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"64 13","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141358173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Soft-Tissue Management Dental Implants with Digitally Customized Healing Abutments: A Pilot Study 使用数字化定制愈合基台的软组织管理种植牙:试点研究
Pub Date : 2024-06-10 DOI: 10.3390/prosthesis6030042
Maurizio De Francesco, E. Ferrara, F. Inchingolo, Grazieli Dalmaschio, Alberto Pispero, A. Inchingolo, G. Dipalma, T. Testori, G. Tartaglia, B. Rapone
Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years. Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups. The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology. The control group received dental implants with immediate loading without customized healing abutments. The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation. Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.001), with pairwise comparisons showing significant differences between multiple time points (p < 0.05). The control group showed less pronounced changes over time. Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement. Randomized controlled trials are needed to confirm these findings.
背景:本试验研究旨在评估数字化定制的愈合基台在拔牙后稳定种植体周围软组织的效果,并评估种植体周围软组织结构在 5 年内的保存情况。材料和方法:将 40 名患者(年龄≥ 25 岁)分为试验组(n = 20)和对照组(n = 20)。试验组接受拔牙后即刻加载的牙科种植体,以及使用 CAD/CAM 技术制作的定制愈合基台。对照组接受的是即刻装载的牙科种植体,没有定制的愈合基台。主要结果是种植体周围软组织边缘与种植体夹具表面之间的距离从基线到种植后 5 年的变化。结果:在试验组中,种植体周围软组织边缘与夹具表面之间的距离从基线到 5 年间有显著的减少(p < 0.001),配对比较显示多个时间点之间有显著差异(p < 0.05)。对照组随着时间的推移变化不太明显。结论:在这项试验性研究的局限性范围内,数字化定制的愈合基台在即刻种植体植入后的 5 年内似乎可以有效地稳定种植体周围的软组织并保护种植体周围的软组织结构。要证实这些研究结果,还需要进行随机对照试验。
{"title":"Soft-Tissue Management Dental Implants with Digitally Customized Healing Abutments: A Pilot Study","authors":"Maurizio De Francesco, E. Ferrara, F. Inchingolo, Grazieli Dalmaschio, Alberto Pispero, A. Inchingolo, G. Dipalma, T. Testori, G. Tartaglia, B. Rapone","doi":"10.3390/prosthesis6030042","DOIUrl":"https://doi.org/10.3390/prosthesis6030042","url":null,"abstract":"Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years. Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups. The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology. The control group received dental implants with immediate loading without customized healing abutments. The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation. Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.001), with pairwise comparisons showing significant differences between multiple time points (p < 0.05). The control group showed less pronounced changes over time. Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement. Randomized controlled trials are needed to confirm these findings.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"120 42","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141360763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Prosthesis
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1