Background/Objectives: Autopolymerizing poly (methyl methacrylate) (PMMA) resin is widely used in provisional restorations; however, its inadequate mechanical properties represent a significant limitation. This study aimed to develop electrospun fibers with chemically reduced graphene oxide (rGO) and to evaluate the effect of fiber reinforcement on the mechanical and physical properties of a commercially available PMMA resin. Methods: Electrospinning was employed to produce nanofibers containing 0.02 wt% and 0.05 wt% rGO within a PMMA matrix. Fiber characterization was performed using SEM-EDS, XRD, TGA/DTG, and FTIR. Following characterization, the fibers were blended into PMMA resin at 1%, 2.5%, and 5% (by weight). The resulting fiber-reinforced composites were tested for flexural strength, elastic modulus, surface roughness, and Vickers microhardness. Results: The addition of 1% and 2.5% PMMA/rGO-0.02 fibers and 1% PMMA/rGO-0.05 fibers significantly improved the flexural strength of PMMA compared with the control group (p < 0.05). A statistically significant increase in elastic modulus was observed only in the group containing 1% PMMA/rGO-0.02 fibers (p < 0.05). However, there were no significant differences in surface roughness or microhardness between the control and experimental groups (p > 0.05). Conclusions: Incorporating electrospun PMMA-rGO fibers into PMMA resin enhances flexural properties at low concentrations without altering surface characteristics. These findings suggest that such fiber-reinforced systems hold promises for improving the mechanical performance and functional longevity of provisional dental restorations under clinical conditions.
{"title":"The Effect of Electrospun PMMA/rGO Fiber Addition on the Improvement of the Physical and Mechanical Properties of PMMA Resin","authors":"Tuğçe Gül ELMAS ALSINI, Işın Kürkçüoğlu, Neslihan Nohut Maşlakcı, Ayşegül Uygun Öksüz","doi":"10.3390/prosthesis7040079","DOIUrl":"https://doi.org/10.3390/prosthesis7040079","url":null,"abstract":"Background/Objectives: Autopolymerizing poly (methyl methacrylate) (PMMA) resin is widely used in provisional restorations; however, its inadequate mechanical properties represent a significant limitation. This study aimed to develop electrospun fibers with chemically reduced graphene oxide (rGO) and to evaluate the effect of fiber reinforcement on the mechanical and physical properties of a commercially available PMMA resin. Methods: Electrospinning was employed to produce nanofibers containing 0.02 wt% and 0.05 wt% rGO within a PMMA matrix. Fiber characterization was performed using SEM-EDS, XRD, TGA/DTG, and FTIR. Following characterization, the fibers were blended into PMMA resin at 1%, 2.5%, and 5% (by weight). The resulting fiber-reinforced composites were tested for flexural strength, elastic modulus, surface roughness, and Vickers microhardness. Results: The addition of 1% and 2.5% PMMA/rGO-0.02 fibers and 1% PMMA/rGO-0.05 fibers significantly improved the flexural strength of PMMA compared with the control group (p < 0.05). A statistically significant increase in elastic modulus was observed only in the group containing 1% PMMA/rGO-0.02 fibers (p < 0.05). However, there were no significant differences in surface roughness or microhardness between the control and experimental groups (p > 0.05). Conclusions: Incorporating electrospun PMMA-rGO fibers into PMMA resin enhances flexural properties at low concentrations without altering surface characteristics. These findings suggest that such fiber-reinforced systems hold promises for improving the mechanical performance and functional longevity of provisional dental restorations under clinical conditions.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"7 4","pages":"79-79"},"PeriodicalIF":0.0,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147890308","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-08-09DOI: 10.3390/prosthesis6040065
Paola Ceresuela, Javier Montero
This study aims to assess the impact of occlusal loadings on peri-implant bone loss by measuring the cantilever of each implant and evaluating the occlusal pattern using PRESCALE® and to examine the relationship between occlusal overload and peri-implant bone loss, including marginal bone loss (MBL) and biomechanical factors, in a sample of 41 patients with a total of 135 implants. In addition, this study examines the influence of occlusal overload among patient groups with no marginal bone loss, unilateral bone loss, and bilateral bone loss. The PRESCALE® quantifies the occlusal area and load along the dental arch. The analysis of variance (ANOVA) was used for comparing quantitative variables between groups and the Pearson correlation coefficient (r) was applied to analyze linear relationships between quantitative variables. The results of occlusal distribution and pressure range were presented using the PRESCALE®. It was found that the mesial cantilever was statistically significantly greater (p < 0.05) for the bilateral bone loss group. Additionally, MBL was significantly proportional to occlusal loading in the left anterior sector (r = 0.47; p < 0.01) and to follow-up time (r = 0.29; p < 0.01), though it was also proportional to implant diameter and length (r = 0.27 and r = 0.20). The presence of a wider cantilever and excess occlusal loading appears to be associated with increased bone loss.
{"title":"Biomechanical Factors in the Prognosis of Implants: A Clinical Study","authors":"Paola Ceresuela, Javier Montero","doi":"10.3390/prosthesis6040065","DOIUrl":"https://doi.org/10.3390/prosthesis6040065","url":null,"abstract":"This study aims to assess the impact of occlusal loadings on peri-implant bone loss by measuring the cantilever of each implant and evaluating the occlusal pattern using PRESCALE® and to examine the relationship between occlusal overload and peri-implant bone loss, including marginal bone loss (MBL) and biomechanical factors, in a sample of 41 patients with a total of 135 implants. In addition, this study examines the influence of occlusal overload among patient groups with no marginal bone loss, unilateral bone loss, and bilateral bone loss. The PRESCALE® quantifies the occlusal area and load along the dental arch. The analysis of variance (ANOVA) was used for comparing quantitative variables between groups and the Pearson correlation coefficient (r) was applied to analyze linear relationships between quantitative variables. The results of occlusal distribution and pressure range were presented using the PRESCALE®. It was found that the mesial cantilever was statistically significantly greater (p < 0.05) for the bilateral bone loss group. Additionally, MBL was significantly proportional to occlusal loading in the left anterior sector (r = 0.47; p < 0.01) and to follow-up time (r = 0.29; p < 0.01), though it was also proportional to implant diameter and length (r = 0.27 and r = 0.20). The presence of a wider cantilever and excess occlusal loading appears to be associated with increased bone loss.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"30 33","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141924759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-07-16DOI: 10.3390/prosthesis6040055
Ahmed Altarazi, J. Haider, Abdulaziz Alhotan, N. Silikas, Hugh Devlin
Background: Advanced manufacturing techniques, such as three-dimensional (3D) printing, use digital models from computer-aided design to produce 3D objects. They are frequently employed in different areas of dentistry, such as orthodontics, oral implantology, and prosthodontics. Purpose: The aim of this review was to provide a comprehensive overview of 3D-printing technology for denture bases and explore the influence of incorporating different fillers into 3D-printed denture base resins on their physical, mechanical, and biological characteristics. Methods: Relevant studies were identified by searching papers published between 2010 and 2023 in several online databases, such as Scopus, PubMed, Cochrane library, and Google Scholar. The main inclusion criteria used during the search was identifying the papers which added nanoparticles in the resin as an agent to bring different functional characteristics within the 3D-printed denture base resin. Furthermore, even though the search criteria were set for finding papers from the past 10 years, development in this field has accelerated in the past 4–5 years. Findings: Various fillers have exhibited promising results in terms of their ability to improve the functional properties of the 3D-printed denture base resins. However, such improvements come at a higher cost with careful resin preparation when considering the filler particles, the fabrication complexities and the extensive post-processing that is required. Conclusions: The use of 3D-printing approaches and fillers to fabricate dentures is associated with significant benefits in terms of imparting functional properties, consistency in fabrication and opportunities for innovation. However, further research is required to acquire a better understanding of the holistic, long-term performance of various filler materials, concentrations, their clinical relevance and particularly the potential health risks from the fillers.
背景:三维(3D)打印等先进制造技术使用计算机辅助设计的数字模型来制造三维物体。它们经常被用于牙科的不同领域,如牙齿矫正、口腔种植和修复。目的:本综述旨在全面概述义齿基托的三维打印技术,并探讨在三维打印义齿基托树脂中加入不同填料对其物理、机械和生物特性的影响。研究方法通过在 Scopus、PubMed、Cochrane library 和 Google Scholar 等多个在线数据库中搜索 2010 年至 2023 年间发表的论文,确定相关研究。搜索过程中使用的主要纳入标准是识别在树脂中添加纳米粒子作为制剂,从而为 3D 打印义齿基底树脂带来不同功能特性的论文。此外,尽管搜索标准设定为查找过去 10 年内的论文,但该领域在过去 4-5 年内的发展速度有所加快。研究结果各种填料在改善 3D 打印义齿基底树脂的功能特性方面取得了可喜的成果。然而,考虑到填料颗粒、制造的复杂性和所需的大量后处理,这些改进需要以较高的成本进行精心的树脂制备。结论:使用三维打印方法和填充物制作假牙在赋予功能特性、制作一致性和创新机会方面具有显著优势。然而,要更好地了解各种填充材料的整体和长期性能、浓度、临床相关性,特别是填充物的潜在健康风险,还需要进一步的研究。
{"title":"Current Progress in the Development of Resin Materials with Nanofillers for 3D Printing of Denture Base","authors":"Ahmed Altarazi, J. Haider, Abdulaziz Alhotan, N. Silikas, Hugh Devlin","doi":"10.3390/prosthesis6040055","DOIUrl":"https://doi.org/10.3390/prosthesis6040055","url":null,"abstract":"Background: Advanced manufacturing techniques, such as three-dimensional (3D) printing, use digital models from computer-aided design to produce 3D objects. They are frequently employed in different areas of dentistry, such as orthodontics, oral implantology, and prosthodontics. Purpose: The aim of this review was to provide a comprehensive overview of 3D-printing technology for denture bases and explore the influence of incorporating different fillers into 3D-printed denture base resins on their physical, mechanical, and biological characteristics. Methods: Relevant studies were identified by searching papers published between 2010 and 2023 in several online databases, such as Scopus, PubMed, Cochrane library, and Google Scholar. The main inclusion criteria used during the search was identifying the papers which added nanoparticles in the resin as an agent to bring different functional characteristics within the 3D-printed denture base resin. Furthermore, even though the search criteria were set for finding papers from the past 10 years, development in this field has accelerated in the past 4–5 years. Findings: Various fillers have exhibited promising results in terms of their ability to improve the functional properties of the 3D-printed denture base resins. However, such improvements come at a higher cost with careful resin preparation when considering the filler particles, the fabrication complexities and the extensive post-processing that is required. Conclusions: The use of 3D-printing approaches and fillers to fabricate dentures is associated with significant benefits in terms of imparting functional properties, consistency in fabrication and opportunities for innovation. However, further research is required to acquire a better understanding of the holistic, long-term performance of various filler materials, concentrations, their clinical relevance and particularly the potential health risks from the fillers.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"42 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141643593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-07-16DOI: 10.3390/prosthesis6040056
G. Spagnuolo, Parisa Soltani
In June 2024, at the European Congress of Dentomaxillofacial Radiology (ECDMFR) in Germany, the first-ever magnetic resonance imaging (MRI) system dedicated to dentistry was introduced [...]
{"title":"Magnetic Resonance Imaging in Digital Dentistry: The Start of a New Era","authors":"G. Spagnuolo, Parisa Soltani","doi":"10.3390/prosthesis6040056","DOIUrl":"https://doi.org/10.3390/prosthesis6040056","url":null,"abstract":"In June 2024, at the European Congress of Dentomaxillofacial Radiology (ECDMFR) in Germany, the first-ever magnetic resonance imaging (MRI) system dedicated to dentistry was introduced [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"4 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141640935","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-07-15DOI: 10.3390/prosthesis6040054
K. I. Afrashtehfar, Moosa Abuzayeda, Colin Alexander Murray
In recent years, artificial intelligence (AI) has emerged as a transformative force in reconstructive implant dentistry [...]
近年来,人工智能(AI)已成为重建种植牙领域的一股变革力量 [...]
{"title":"Artificial Intelligence in Reconstructive Implant Dentistry—Current Perspectives","authors":"K. I. Afrashtehfar, Moosa Abuzayeda, Colin Alexander Murray","doi":"10.3390/prosthesis6040054","DOIUrl":"https://doi.org/10.3390/prosthesis6040054","url":null,"abstract":"In recent years, artificial intelligence (AI) has emerged as a transformative force in reconstructive implant dentistry [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"22 10","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141648051","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-07-10DOI: 10.3390/prosthesis6040053
R. Delgado-Ruiz, Ido Brintouch, Aisha Ali, Yiwei Fang, George E Romanos, Miriam Rafailovich
Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate (PMMA)-based materials. These methods have served well for many years. More recently, the incorporation of computer-aided design and computer-aided manufacturing (CAD/CAM) to fabricate complete dentures has been shown to enhance the dentures’ mechanical properties, including resistance to wear and impact strength. This study aims to investigate the mechanical properties and fracture types of CAD/CAM denture base materials (both milled and printed) as compared to a novel proprietary method that embeds a 3D-printed framework within PMMA-milled blocks. The null hypothesis is that incorporating a 3D-printed framework does not affect the mechanical properties of milled PMMA blocks. Methods: Three groups of bars were fabricated using CAD/CAM methods: printed (P), milled (M), and milled with a 3D-printed metallic framework reinforcement (M + F). A three-point bending test evaluated deformation, followed by an impact fracture test for fracture toughness. A descriptive fractographic analysis assessed the fracture characteristics. A statistical analysis using a paired t-test compared the differences between the groups. Results: The P group showed more elastic deformation than the M and M + F groups (p < 0.05). The M + F group achieved a higher fracture toughness as compared to the M and P groups (p < 0.05). Conclusions: Within the limitations of this experimental study, the null hypothesis can be rejected. Milled samples with an embedded 3D-printed titanium framework possess higher resistance to impact than milled samples without frameworks, and printed samples and milled samples with embedded 3d-printed titanium frameworks present increased flexural strength and lower elastic deformation as compared to milled samples without frameworks and printed samples.
背景:全口义齿应能承受咬合力和磨损。然而,随着时间的推移,假牙会出现疲劳、裂缝、崩裂和断裂。制作全口义齿的传统方法包括注射成型、热固化以及使用微波处理聚甲基丙烯酸甲酯(PMMA)材料。这些方法多年来一直行之有效。最近,计算机辅助设计和计算机辅助制造(CAD/CAM)技术被用于制造全口义齿,已被证明可以提高义齿的机械性能,包括耐磨性和抗冲击强度。本研究旨在研究 CAD/CAM 义齿基托材料(包括铣制和打印)的机械性能和断裂类型,并将其与在 PMMA 铣制块中嵌入 3D 打印框架的新型专有方法进行比较。零假设是嵌入三维打印框架不会影响磨制 PMMA 块的机械性能。方法:使用 CAD/CAM 方法制造了三组棒材:打印(P)、铣削(M)和铣削加三维打印金属框架加固(M + F)。三点弯曲测试评估了变形情况,随后进行了冲击断裂测试以评估断裂韧性。描述性断裂分析评估了断裂特征。使用配对 t 检验进行统计分析,比较组间差异。结果显示P 组比 M 组和 M + F 组显示出更大的弹性变形(p < 0.05)。与 M 组和 P 组相比,M + F 组的断裂韧性更高(P < 0.05)。结论:在本实验研究的限制条件下,可以拒绝零假设。与不带框架的磨制样品相比,带有嵌入式三维打印钛框架的磨制样品具有更高的抗冲击性,与不带框架的磨制样品和打印样品相比,带有嵌入式三维打印钛框架的打印样品和磨制样品具有更高的抗弯强度和更低的弹性变形。
{"title":"The Effect of the Incorporation of a 3D-Printed Titanium Framework on the Mechanical Properties CAD/CAM Denture Base Materials","authors":"R. Delgado-Ruiz, Ido Brintouch, Aisha Ali, Yiwei Fang, George E Romanos, Miriam Rafailovich","doi":"10.3390/prosthesis6040053","DOIUrl":"https://doi.org/10.3390/prosthesis6040053","url":null,"abstract":"Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate (PMMA)-based materials. These methods have served well for many years. More recently, the incorporation of computer-aided design and computer-aided manufacturing (CAD/CAM) to fabricate complete dentures has been shown to enhance the dentures’ mechanical properties, including resistance to wear and impact strength. This study aims to investigate the mechanical properties and fracture types of CAD/CAM denture base materials (both milled and printed) as compared to a novel proprietary method that embeds a 3D-printed framework within PMMA-milled blocks. The null hypothesis is that incorporating a 3D-printed framework does not affect the mechanical properties of milled PMMA blocks. Methods: Three groups of bars were fabricated using CAD/CAM methods: printed (P), milled (M), and milled with a 3D-printed metallic framework reinforcement (M + F). A three-point bending test evaluated deformation, followed by an impact fracture test for fracture toughness. A descriptive fractographic analysis assessed the fracture characteristics. A statistical analysis using a paired t-test compared the differences between the groups. Results: The P group showed more elastic deformation than the M and M + F groups (p < 0.05). The M + F group achieved a higher fracture toughness as compared to the M and P groups (p < 0.05). Conclusions: Within the limitations of this experimental study, the null hypothesis can be rejected. Milled samples with an embedded 3D-printed titanium framework possess higher resistance to impact than milled samples without frameworks, and printed samples and milled samples with embedded 3d-printed titanium frameworks present increased flexural strength and lower elastic deformation as compared to milled samples without frameworks and printed samples.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"2 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141658752","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-06-12DOI: 10.3390/prosthesis6030046
Kirsten Sekura, Carolin Erbel, Matthias Karl, T. Grobecker-Karl
Mechanical and thermal trauma during implant surgery may be reasons for initial peri-implant bone loss. Temperature development during drilling and implant insertion were quantified in this series of in vitro and animal experiments. Polyurethane foam material mimicking different classes of alveolar bone was used as a model material for simulating implant surgery. Using thermocouples, temperature development was determined in the model material at depths of 3 mm and 10 mm during site preparation and implant insertion. Additionally, an infrared camera allowed for measuring drill temperatures both in vitro and as part of an animal trial using an intraoral minipig model. Drill diameter and repeated usage of drills did not have a major effect on temperature generation. The addition of a diamond-like carbon coating, bone density, predrilling, and irrigation heavily affected intraosseous temperatures. In vivo, applying regular drill protocols, an intraosseous temperature rise of approximately 3 °K was determined. Implant geometry as well as the amount of undersizing of an osteotomy governed heat generation during implant insertion. Drill protocols and the amount of undersizing of an implant osteotomy constitute parameters by which clinicians can limit trauma during implant surgery.
{"title":"Determinants of Temperature Development during Dental Implant Surgery","authors":"Kirsten Sekura, Carolin Erbel, Matthias Karl, T. Grobecker-Karl","doi":"10.3390/prosthesis6030046","DOIUrl":"https://doi.org/10.3390/prosthesis6030046","url":null,"abstract":"Mechanical and thermal trauma during implant surgery may be reasons for initial peri-implant bone loss. Temperature development during drilling and implant insertion were quantified in this series of in vitro and animal experiments. Polyurethane foam material mimicking different classes of alveolar bone was used as a model material for simulating implant surgery. Using thermocouples, temperature development was determined in the model material at depths of 3 mm and 10 mm during site preparation and implant insertion. Additionally, an infrared camera allowed for measuring drill temperatures both in vitro and as part of an animal trial using an intraoral minipig model. Drill diameter and repeated usage of drills did not have a major effect on temperature generation. The addition of a diamond-like carbon coating, bone density, predrilling, and irrigation heavily affected intraosseous temperatures. In vivo, applying regular drill protocols, an intraosseous temperature rise of approximately 3 °K was determined. Implant geometry as well as the amount of undersizing of an osteotomy governed heat generation during implant insertion. Drill protocols and the amount of undersizing of an implant osteotomy constitute parameters by which clinicians can limit trauma during implant surgery.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"120 28","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141351901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-06-12DOI: 10.3390/prosthesis6030047
A. Otte
If you want to buy a new car today, you can expect a flood of digital features and assistance systems that initially make the analog human heart beat faster [...]
{"title":"Neuroprosthetics of the Hand: Current Hot Research Topics, Research Trends and Challenges, and Recent Innovations","authors":"A. Otte","doi":"10.3390/prosthesis6030047","DOIUrl":"https://doi.org/10.3390/prosthesis6030047","url":null,"abstract":"If you want to buy a new car today, you can expect a flood of digital features and assistance systems that initially make the analog human heart beat faster [...]","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"129 16","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141351489","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-06-11DOI: 10.3390/prosthesis6030045
Denise Bolonhezi Ribeiro, L. Sartori, María Verónica González Méndez, Roger Burgo de Souza, Daniel Prado Campos, Paulo Broniera Júnior, José J. A. Mendes Junior, Eddy Krueger
Purpose: In incomplete spinal cord injury (SCI), there is a partial decrease in motor or sensory or autonomic function. Mainly due to the motor impairment in SCI, a muscle–machine interface is a tool that can bring functional benefits to this population. Objective: To investigate the feasibility of the non-invasive myoelectric signal–functional electrical stimulation (MES-FES) interface on the response of the quadriceps muscle in an individual with incomplete SCI. Methods: This is a quasi-experimental, uncontrolled, longitudinal case report study carried out with an individual with incomplete SCI in the chronic phase. The assessments performed before (pre) and after eight (post8) interventions were neuromuscular assessment (surface electromyography (EMG) in rectus femoris (RF) and vastus lateralis (VL) muscles); muscle strength (load cell); knee extension range of motion (goniometry); spasticity (Modified Ashworth Scale); and quality of life (Spinal Cord Injury Quality-of-Life Questionnaire (SCI-QoL.Br)). The MES-FES interface was associated with physical therapy exercises on the extension knee joint muscle group. Results: Improvement in neuromuscular activation (normalized increase in EMGRMS of 2% (RF) and 3.3% (VL)) and synchronism of the motor units (normalized reduction in EMGMDF of 22.8% (RF) and 5.9% (VL)); 1.4 kgf increase in quadriceps strength; 10.6° increase in knee joint extension amplitude; 1 point spasticity reduction; improved quality of life, confirmed by a 12-point reduction in the SCI-QoL.Br score. Moreover, along with interventions, the participant increased the correct FES activation rate, indicating a user learning curve (ρ = 0.78, p-value = 0.04). Conclusions: The MES-FES interface associated with physical therapy promotes neuromuscular and quality of life improvements in the SCI participant.
{"title":"MES-FES Interface Enhances Quadriceps Muscle Response in Sitting Position in Incomplete Spinal Cord Injury: Pilot Study","authors":"Denise Bolonhezi Ribeiro, L. Sartori, María Verónica González Méndez, Roger Burgo de Souza, Daniel Prado Campos, Paulo Broniera Júnior, José J. A. Mendes Junior, Eddy Krueger","doi":"10.3390/prosthesis6030045","DOIUrl":"https://doi.org/10.3390/prosthesis6030045","url":null,"abstract":"Purpose: In incomplete spinal cord injury (SCI), there is a partial decrease in motor or sensory or autonomic function. Mainly due to the motor impairment in SCI, a muscle–machine interface is a tool that can bring functional benefits to this population. Objective: To investigate the feasibility of the non-invasive myoelectric signal–functional electrical stimulation (MES-FES) interface on the response of the quadriceps muscle in an individual with incomplete SCI. Methods: This is a quasi-experimental, uncontrolled, longitudinal case report study carried out with an individual with incomplete SCI in the chronic phase. The assessments performed before (pre) and after eight (post8) interventions were neuromuscular assessment (surface electromyography (EMG) in rectus femoris (RF) and vastus lateralis (VL) muscles); muscle strength (load cell); knee extension range of motion (goniometry); spasticity (Modified Ashworth Scale); and quality of life (Spinal Cord Injury Quality-of-Life Questionnaire (SCI-QoL.Br)). The MES-FES interface was associated with physical therapy exercises on the extension knee joint muscle group. Results: Improvement in neuromuscular activation (normalized increase in EMGRMS of 2% (RF) and 3.3% (VL)) and synchronism of the motor units (normalized reduction in EMGMDF of 22.8% (RF) and 5.9% (VL)); 1.4 kgf increase in quadriceps strength; 10.6° increase in knee joint extension amplitude; 1 point spasticity reduction; improved quality of life, confirmed by a 12-point reduction in the SCI-QoL.Br score. Moreover, along with interventions, the participant increased the correct FES activation rate, indicating a user learning curve (ρ = 0.78, p-value = 0.04). Conclusions: The MES-FES interface associated with physical therapy promotes neuromuscular and quality of life improvements in the SCI participant.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"64 13","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141358173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Pub Date : 2024-06-10DOI: 10.3390/prosthesis6030042
Maurizio De Francesco, E. Ferrara, F. Inchingolo, Grazieli Dalmaschio, Alberto Pispero, A. Inchingolo, G. Dipalma, T. Testori, G. Tartaglia, B. Rapone
Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years. Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups. The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology. The control group received dental implants with immediate loading without customized healing abutments. The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation. Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.001), with pairwise comparisons showing significant differences between multiple time points (p < 0.05). The control group showed less pronounced changes over time. Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement. Randomized controlled trials are needed to confirm these findings.
{"title":"Soft-Tissue Management Dental Implants with Digitally Customized Healing Abutments: A Pilot Study","authors":"Maurizio De Francesco, E. Ferrara, F. Inchingolo, Grazieli Dalmaschio, Alberto Pispero, A. Inchingolo, G. Dipalma, T. Testori, G. Tartaglia, B. Rapone","doi":"10.3390/prosthesis6030042","DOIUrl":"https://doi.org/10.3390/prosthesis6030042","url":null,"abstract":"Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years. Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups. The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology. The control group received dental implants with immediate loading without customized healing abutments. The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation. Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.001), with pairwise comparisons showing significant differences between multiple time points (p < 0.05). The control group showed less pronounced changes over time. Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement. Randomized controlled trials are needed to confirm these findings.","PeriodicalId":474580,"journal":{"name":"Prosthesis","volume":"120 42","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141360763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}