首页 > 最新文献
paperpass

International Biomechanics最新文献

英文 中文
An applied paradigm for simple analysis of the lower limb kinematic chain in explosive movements: an example using the fencing foil attacking lunge 爆发力动作中下肢运动链的简单分析应用范例:以击剑箭步为例
Q2 Medicine Pub Date : 2018-01-01 DOI: 10.1080/23335432.2018.1454342
Francis Mulloy, D. Mullineaux, P. Graham-Smith, G. Irwin
Abstract A simple method to quantify the kinematic chain in a propulsive task would facilitate assessment of athlete effectiveness. The study’s aim was to assess if the kinematic chain distinguishes between skill levels. Fencers were separated into two groups based on attacking lunge ability (7 skilled; 8 novices). Rear leg 3D joint angular extension velocity magnitudes and timings, sword kinematics and rear leg kinetics were obtained in the propulsion phase of the attacking lunge. Skilled fencers obtained greater sword velocity (3.24 ± 0.24 m∙s−1 vs. 2.69 ± 0.29 m∙s−1; p = 0.02). The skilled group had a greater sequential kinematic chain of the hip, knee and ankle, demonstrated by significantly greater ankle angular velocity (9.1 ± 2.1 rad·s−1 skilled; 5.4 ± 2.9 rad·s−1 novice). Ankle plantarflexion velocity showed a strong positive correlation with horizontal peak force (r = 0.81; p < 0.01). The skilled group demonstrated greater horizontal impulse (1.85 ± 0.29 N·s·kg−1 skilled; 1.45 ± 0.32 N·s·kg−1 novice), suggesting greater effectiveness in applying the kinematic chain towards horizontal propulsion. Analysis of the kinematic chain, which was able to distinguish between skill levels in a propulsive task, is an effective and simple paradigm to assess whole limb contributions to propulsive movements.
一种简单的方法来量化运动链的推进任务将有助于评估运动员的有效性。这项研究的目的是评估运动链是否能区分不同的技能水平。击剑运动员根据攻击弓步能力分为两组(熟练7人;8新手)。获得了攻击弓步推进阶段的后腿三维关节角伸展速度大小和时间、剑运动学和后腿动力学。熟练的击剑运动员获得了更高的剑速(3.24±0.24 m∙s−1 vs. 2.69±0.29 m∙s−1);P = 0.02)。熟练组髋关节、膝关节和踝关节的顺序运动链更大,表现为踝关节角速度显著增加(9.1±2.1 rad·s−1熟练组;5.4±2.9 rad·s−1新手)。踝关节跖屈曲速度与水平峰值力呈显著正相关(r = 0.81;P < 0.01)。熟练组表现出更大的水平冲量(1.85±0.29 N·s·kg−1熟练;1.45±0.32 N·s·kg−1新手),表明运动链应用于水平推进更有效。运动链的分析能够区分推进任务中的技能水平,是评估全肢体对推进运动贡献的一种有效而简单的范例。
{"title":"An applied paradigm for simple analysis of the lower limb kinematic chain in explosive movements: an example using the fencing foil attacking lunge","authors":"Francis Mulloy, D. Mullineaux, P. Graham-Smith, G. Irwin","doi":"10.1080/23335432.2018.1454342","DOIUrl":"https://doi.org/10.1080/23335432.2018.1454342","url":null,"abstract":"Abstract A simple method to quantify the kinematic chain in a propulsive task would facilitate assessment of athlete effectiveness. The study’s aim was to assess if the kinematic chain distinguishes between skill levels. Fencers were separated into two groups based on attacking lunge ability (7 skilled; 8 novices). Rear leg 3D joint angular extension velocity magnitudes and timings, sword kinematics and rear leg kinetics were obtained in the propulsion phase of the attacking lunge. Skilled fencers obtained greater sword velocity (3.24 ± 0.24 m∙s−1 vs. 2.69 ± 0.29 m∙s−1; p = 0.02). The skilled group had a greater sequential kinematic chain of the hip, knee and ankle, demonstrated by significantly greater ankle angular velocity (9.1 ± 2.1 rad·s−1 skilled; 5.4 ± 2.9 rad·s−1 novice). Ankle plantarflexion velocity showed a strong positive correlation with horizontal peak force (r = 0.81; p < 0.01). The skilled group demonstrated greater horizontal impulse (1.85 ± 0.29 N·s·kg−1 skilled; 1.45 ± 0.32 N·s·kg−1 novice), suggesting greater effectiveness in applying the kinematic chain towards horizontal propulsion. Analysis of the kinematic chain, which was able to distinguish between skill levels in a propulsive task, is an effective and simple paradigm to assess whole limb contributions to propulsive movements.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"5 1","pages":"9 - 16"},"PeriodicalIF":0.0,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2018.1454342","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46733742","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Kinematic differences between hitting off a tee versus front toss in collegiate softball players 大学垒球运动员开球与前抛球之间的运动学差异
Q2 Medicine Pub Date : 2018-01-01 DOI: 10.1080/23335432.2018.1472038
J. Washington, G. Oliver
Abstract The purpose of this study was to compare kinematics of two hitting conditions: stationary tee and front toss from a practice pitcher. Twenty-two NCAA Division I Collegiate softball players (20.3 ± 1.5 years; 166.6 ± 6.3 cm; 68.0 ± 7.5 kg) participated. Participants executed five maximum effort swings from a stationary tee and five swings from a front toss practice pitcher. Data for each kinematic variable were averaged for the five maximal effort swings of each condition and analyzed using a within-subject repeated measures ANOVA. The front toss condition revealed significantly greater lead knee flexion at foot contact and greater trunk rotation towards the back side at ball contact. The tee condition revealed greater trunk lateral flexion to the back side at foot contact, greater trunk rotation towards the lead side at follow through, and greater pelvis rotation towards the lead side at follow through. This study most significantly indicates that swing mechanics are different between specific training methods; therefore, athletes should implement techniques most applicable to a competition setting such as the front toss.
摘要:本研究的目的是比较两种击球条件:静止发球和前抛从练习投手的运动学。22名NCAA甲级大学垒球运动员(20.3±1.5岁;166.6±6.3 cm;68.0±7.5 kg)参加。参与者在静止的球座上进行了五次最大努力挥杆,在投球练习投手上进行了五次挥杆。每个运动学变量的数据被平均为每个条件下的五个最大努力摆动,并使用受试者重复测量方差分析。前倾情况显示,在足部接触时膝关节弯曲明显增加,在球接触时躯干向后侧旋转明显增加。三通条件显示,在足部接触时躯干向后侧侧屈较大,在跟进时躯干向前侧旋转较大,在跟进时骨盆向前侧旋转较大。该研究最显著地表明,不同训练方法的挥拍力学存在差异;因此,运动员应该运用最适用于比赛环境的技术,比如前抛。
{"title":"Kinematic differences between hitting off a tee versus front toss in collegiate softball players","authors":"J. Washington, G. Oliver","doi":"10.1080/23335432.2018.1472038","DOIUrl":"https://doi.org/10.1080/23335432.2018.1472038","url":null,"abstract":"Abstract The purpose of this study was to compare kinematics of two hitting conditions: stationary tee and front toss from a practice pitcher. Twenty-two NCAA Division I Collegiate softball players (20.3 ± 1.5 years; 166.6 ± 6.3 cm; 68.0 ± 7.5 kg) participated. Participants executed five maximum effort swings from a stationary tee and five swings from a front toss practice pitcher. Data for each kinematic variable were averaged for the five maximal effort swings of each condition and analyzed using a within-subject repeated measures ANOVA. The front toss condition revealed significantly greater lead knee flexion at foot contact and greater trunk rotation towards the back side at ball contact. The tee condition revealed greater trunk lateral flexion to the back side at foot contact, greater trunk rotation towards the lead side at follow through, and greater pelvis rotation towards the lead side at follow through. This study most significantly indicates that swing mechanics are different between specific training methods; therefore, athletes should implement techniques most applicable to a competition setting such as the front toss.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"5 1","pages":"30 - 35"},"PeriodicalIF":0.0,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2018.1472038","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46829841","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Reactive balance to unanticipated trip-like perturbations: a treadmill-based study examining effect of aging and stroke on fall risk 对意外绊倒样扰动的反应性平衡:一项基于跑步机的研究,研究衰老和中风对跌倒风险的影响
Q2 Medicine Pub Date : 2018-01-01 DOI: 10.1080/23335432.2018.1512375
Mansi P. Joshi, Prakruti Patel, T. Bhatt
ABSTRACT The purpose of this study was to examine the mechanism of fall risk in community-dwelling ambulatory hemiplegic stroke survivors when exposed to a sudden, trip-like support surface perturbation in standing. Participants (n = 14 / group) included stroke survivors, Age-similar older controls (AC), and Young controls (YC) experienced trip-like perturbation on a motorized treadmill. The primary outcomes were COM state control (measured as COM position (XCOM/BOS) and velocity (VCOM/BOS) relative to the base of support (BOS)) and the vertical limb support recorded as the extent of hip descent. All participants demonstrated forward loss of balance (FLOB) followed by an equal first compensatory step length. At step touchdown, stroke survivors demonstrated lower COM state stability and increased trunk flexion than the YC group. Stroke survivors also demonstrated greater hip descent than YC and AC groups, as they first stepped with their non-paretic limb. For the second compensatory step, the stroke survivors stepped with their paretic limb. However, unlike the AC group, they were unable to control VCOM/BOS despite a longer compensatory step. In conclusion, poor control of COM state, impaired trunk control and inability of the paretic limb to provide vertical limb support may explain the higher fall-risk in stroke survivors.
摘要:本研究的目的是研究社区居住的非能动偏瘫中风幸存者站立时暴露于突然的绊倒样支撑面扰动时跌倒风险的机制。参与者(n = 14 /组)包括中风幸存者,年龄相似的老年对照组(AC)和年轻对照组(YC),他们在电动跑步机上经历了类似旅行的扰动。主要结果是COM状态控制(测量为COM位置(XCOM/BOS)和相对于支撑底(BOS)的速度(VCOM/BOS))和记录为髋关节下降程度的垂直肢体支持。所有参与者都表现出前向平衡丧失(FLOB),随后是相同的第一步补偿性步长。在台阶着地时,中风幸存者表现出较低的COM状态稳定性和较YC组增加的躯干屈曲。与YC组和AC组相比,中风幸存者在第一次使用非麻痹肢体时表现出更大的髋关节下降。在第二步补偿中,中风幸存者用他们的麻痹肢体行走。然而,与AC组不同的是,尽管有较长的补偿步骤,他们仍无法控制VCOM/BOS。综上所述,COM状态控制不佳、躯干控制受损以及瘫痪肢体无法提供垂直肢体支持可能是脑卒中幸存者摔倒风险较高的原因。
{"title":"Reactive balance to unanticipated trip-like perturbations: a treadmill-based study examining effect of aging and stroke on fall risk","authors":"Mansi P. Joshi, Prakruti Patel, T. Bhatt","doi":"10.1080/23335432.2018.1512375","DOIUrl":"https://doi.org/10.1080/23335432.2018.1512375","url":null,"abstract":"ABSTRACT The purpose of this study was to examine the mechanism of fall risk in community-dwelling ambulatory hemiplegic stroke survivors when exposed to a sudden, trip-like support surface perturbation in standing. Participants (n = 14 / group) included stroke survivors, Age-similar older controls (AC), and Young controls (YC) experienced trip-like perturbation on a motorized treadmill. The primary outcomes were COM state control (measured as COM position (XCOM/BOS) and velocity (VCOM/BOS) relative to the base of support (BOS)) and the vertical limb support recorded as the extent of hip descent. All participants demonstrated forward loss of balance (FLOB) followed by an equal first compensatory step length. At step touchdown, stroke survivors demonstrated lower COM state stability and increased trunk flexion than the YC group. Stroke survivors also demonstrated greater hip descent than YC and AC groups, as they first stepped with their non-paretic limb. For the second compensatory step, the stroke survivors stepped with their paretic limb. However, unlike the AC group, they were unable to control VCOM/BOS despite a longer compensatory step. In conclusion, poor control of COM state, impaired trunk control and inability of the paretic limb to provide vertical limb support may explain the higher fall-risk in stroke survivors.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"5 1","pages":"75 - 87"},"PeriodicalIF":0.0,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2018.1512375","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42529502","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Effects of a semi-rigid ankle brace on ankle joint loading during landing on inclined surfaces 半刚性踝关节支架在倾斜表面着陆时对踝关节载荷的影响
Q2 Medicine Pub Date : 2018-01-01 DOI: 10.1080/23335432.2018.1481767
I. Theodorakos, Jan Rueterbories, M. Lund, E. Eils, M. Andersen, M. de Zee, U. Kersting
ABSTRACT Ankle bracing is commonly used to prevent ankle sprain occurrences. The present study investigated the effects of a semi-rigid ankle brace on the ankle joint complex during landing on inclined surfaces. Seventeen recreational athletes performed a single leg landing task onto three different surface alignments (everted, neutral, inverted), with and without the brace. Ground reaction forces (GRF), kinematics, and brace pressure were recorded. Six two-way repeated measures MANOVA tested for differences in GRF, talocrural and subtalar kinematics and kinetics. Participants landed with a significantly less plantar flexed (P < 0.001) and more everted (P = 0.001) foot during the braced condition. Although no differences were observed for the joint moments, an increased subtalar compression force (P = 0.009) was observed with the brace. Landing on the inverted surface resulted in significantly higher peak magnitudes of the vertical and the mediolateral GRF and the talocrural inversion moment compared to landing on the neutral surface. Ankle bracing altered ankle kinematics by restricting the ROM of the ankle joint complex. This study confirmed that landing on inverted surfaces may increase the risk for lateral ankle ligaments injuries. The significantly higher subtalar compression force during the brace condition might contribute to overuse injuries.
踝关节支具是预防踝关节扭伤的常用手段。本研究探讨了半刚性踝关节支架在倾斜表面着陆时对踝关节复合体的影响。17名休闲运动员进行了单腿着地任务,在三种不同的表面对齐(倾斜、中立、倒置)上,有和没有支架。记录地面反作用力(GRF)、运动学和支撑压力。六种双向重复测量方差分析测试了GRF、距骨和距下运动学和动力学的差异。在支撑条件下,参与者着地时足底屈曲明显减少(P < 0.001),而脚掌外翻明显增加(P = 0.001)。虽然没有观察到关节力矩的差异,但观察到支架增加了距下压缩力(P = 0.009)。降落在倒立表面时,垂直、中外侧GRF峰值和距地逆转力矩显著高于降落在中性表面时。踝关节支架通过限制踝关节复合体的ROM改变踝关节的运动学。这项研究证实,在倒置的表面着陆可能会增加踝关节外侧韧带损伤的风险。在支具状态下明显较高的距下压迫力可能导致过度使用损伤。
{"title":"Effects of a semi-rigid ankle brace on ankle joint loading during landing on inclined surfaces","authors":"I. Theodorakos, Jan Rueterbories, M. Lund, E. Eils, M. Andersen, M. de Zee, U. Kersting","doi":"10.1080/23335432.2018.1481767","DOIUrl":"https://doi.org/10.1080/23335432.2018.1481767","url":null,"abstract":"ABSTRACT Ankle bracing is commonly used to prevent ankle sprain occurrences. The present study investigated the effects of a semi-rigid ankle brace on the ankle joint complex during landing on inclined surfaces. Seventeen recreational athletes performed a single leg landing task onto three different surface alignments (everted, neutral, inverted), with and without the brace. Ground reaction forces (GRF), kinematics, and brace pressure were recorded. Six two-way repeated measures MANOVA tested for differences in GRF, talocrural and subtalar kinematics and kinetics. Participants landed with a significantly less plantar flexed (P < 0.001) and more everted (P = 0.001) foot during the braced condition. Although no differences were observed for the joint moments, an increased subtalar compression force (P = 0.009) was observed with the brace. Landing on the inverted surface resulted in significantly higher peak magnitudes of the vertical and the mediolateral GRF and the talocrural inversion moment compared to landing on the neutral surface. Ankle bracing altered ankle kinematics by restricting the ROM of the ankle joint complex. This study confirmed that landing on inverted surfaces may increase the risk for lateral ankle ligaments injuries. The significantly higher subtalar compression force during the brace condition might contribute to overuse injuries.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"5 1","pages":"46 - 56"},"PeriodicalIF":0.0,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2018.1481767","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48832241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
How to choose and interpret similarity indices to quantify the variability in gait joint kinematics 如何选择和解释相似性指数来量化步态关节运动学的可变性
Q2 Medicine Pub Date : 2018-01-01 DOI: 10.1080/23335432.2018.1426496
R. Di Marco, E. Scalona, Alessandra Pacilli, P. Cappa, C. Mazzà, S. Rossi
Abstract Repeatability and reproducibility indices are often used in gait analysis to validate models and assess patients in their follow-up. When comparing joint kinematics, their interpretation can be ambiguous due to a lack of understanding of the exact sources of their variations. This paper studied four indices (Root Mean Square Deviation, Mean Absolute Variability, Coefficient of Multiple Correlation, and Linear Fit Method) in relation to five confusing-factors: joints’ range of motion, sample-by-sample amplitude variability, offset, time shift and curve shape. A first simulation was conducted to test the mathematics behind each index. A second simulation tested the influence of the curve shape on the indices using a Fourier’s decomposition. The Coefficient of Multiple Correlation and the Linear Fit method Coefficients were independent from the range of motion. Different Coefficients of Multiple Correlation were found among different joints, leading to misinterpretation of the results. The Linear Fit Method coefficients should not be adopted when time shift increases. Root Mean Square Deviation and Mean Absolute Variability were sensitive to all the confusing-factors. The Linear Fit Method coefficients seemed to be the most suitable to assess gait data variability, complemented with Root Mean Square Deviation or Mean Absolute Variability as measurements of data dispersion.
摘要步态分析中经常使用重复性和再现性指标来验证模型并在随访中评估患者。在比较关节运动学时,由于缺乏对其变化的确切来源的了解,它们的解释可能会模糊不清。本文研究了四个指标(均方根偏差、平均绝对变异性、多重相关系数和线性拟合方法)与五个混淆因素的关系:关节的运动范围、逐样本幅度变异性、偏移、时移和曲线形状。进行了第一次模拟,以测试每个指数背后的数学。第二个模拟使用傅立叶分解测试了曲线形状对指数的影响。多重相关系数和线性拟合法系数与运动范围无关。在不同的关节中发现了不同的多重相关系数,导致对结果的误解。当时间偏移增加时,不应采用线性拟合方法系数。均方根偏差和平均绝对变异性对所有混淆因素都很敏感。线性拟合法系数似乎最适合评估步态数据的变异性,并辅以均方根偏差或平均绝对变异性作为数据离散度的测量。
{"title":"How to choose and interpret similarity indices to quantify the variability in gait joint kinematics","authors":"R. Di Marco, E. Scalona, Alessandra Pacilli, P. Cappa, C. Mazzà, S. Rossi","doi":"10.1080/23335432.2018.1426496","DOIUrl":"https://doi.org/10.1080/23335432.2018.1426496","url":null,"abstract":"Abstract Repeatability and reproducibility indices are often used in gait analysis to validate models and assess patients in their follow-up. When comparing joint kinematics, their interpretation can be ambiguous due to a lack of understanding of the exact sources of their variations. This paper studied four indices (Root Mean Square Deviation, Mean Absolute Variability, Coefficient of Multiple Correlation, and Linear Fit Method) in relation to five confusing-factors: joints’ range of motion, sample-by-sample amplitude variability, offset, time shift and curve shape. A first simulation was conducted to test the mathematics behind each index. A second simulation tested the influence of the curve shape on the indices using a Fourier’s decomposition. The Coefficient of Multiple Correlation and the Linear Fit method Coefficients were independent from the range of motion. Different Coefficients of Multiple Correlation were found among different joints, leading to misinterpretation of the results. The Linear Fit Method coefficients should not be adopted when time shift increases. Root Mean Square Deviation and Mean Absolute Variability were sensitive to all the confusing-factors. The Linear Fit Method coefficients seemed to be the most suitable to assess gait data variability, complemented with Root Mean Square Deviation or Mean Absolute Variability as measurements of data dispersion.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"5 1","pages":"1 - 8"},"PeriodicalIF":0.0,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2018.1426496","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43656905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Scapular kinematic reconstruction – segmental optimization, multibody optimization with open-loop or closed-loop chains: which one should be preferred? 肩胛骨运动学重建——节段优化,开环链或闭环链的多体优化:应该首选哪一种?
Q2 Medicine Pub Date : 2017-11-03 DOI: 10.1080/23335432.2017.1405741
B. Michaud, S. Duprey, M. Begon
Abstract Several numerical approaches have been developed to address the soft tissue artefact, such as the segmental optimization and multibody kinematics optimizations using either open-loop or closed-loop chains. However, it is still not clear which method is the most efficient for scapular kinematics reconstruction. In this study, six kinematic models were compared to a silver standard, i.e. a scapula palpator, during a series of 55 postures with maximal amplitudes of both the arm and scapula performed by 15 subjects. The most accurate approaches were the multibody optimization with a closed-loop chain and the segmental optimization. They provided averaged scapula misorientations of 14.9 ± 6.7° and 16 ± 7.1, respectively. Regarding the closed-loop chain integrating a point-to-ellipsoid scapulothoracic joint, the ellipsoid providing the most accurate results was a thorax-size ellipsoid fitting the area browsed by the scapula. Eventually, considering the high implementation costs of a multibody kinematics optimization, the segmental optimization could be considered as appropriate for scapular kinematics reconstruction.
摘要:针对软组织伪影问题,已经发展了几种数值方法,如利用开环或闭环链进行分段优化和多体运动学优化。然而,对于肩胛骨的运动学重建,哪一种方法是最有效的尚不清楚。在这项研究中,6个运动学模型与银标准(即触诊肩胛骨)在15名受试者进行的一系列55种姿势中,手臂和肩胛骨的最大振幅进行了比较。最精确的方法是带闭环链的多体优化和分段优化。他们提供的平均肩胛骨偏差分别为14.9±6.7°和16±7.1°。对于积分点-椭球形肩胛骨关节的闭环链,提供最准确结果的椭球体是拟合肩胛骨浏览区域的胸廓大小的椭球体。最后,考虑到多体运动学优化的实现成本较高,可以认为分段优化适合于肩胛骨运动学重构。
{"title":"Scapular kinematic reconstruction – segmental optimization, multibody optimization with open-loop or closed-loop chains: which one should be preferred?","authors":"B. Michaud, S. Duprey, M. Begon","doi":"10.1080/23335432.2017.1405741","DOIUrl":"https://doi.org/10.1080/23335432.2017.1405741","url":null,"abstract":"Abstract Several numerical approaches have been developed to address the soft tissue artefact, such as the segmental optimization and multibody kinematics optimizations using either open-loop or closed-loop chains. However, it is still not clear which method is the most efficient for scapular kinematics reconstruction. In this study, six kinematic models were compared to a silver standard, i.e. a scapula palpator, during a series of 55 postures with maximal amplitudes of both the arm and scapula performed by 15 subjects. The most accurate approaches were the multibody optimization with a closed-loop chain and the segmental optimization. They provided averaged scapula misorientations of 14.9 ± 6.7° and 16 ± 7.1, respectively. Regarding the closed-loop chain integrating a point-to-ellipsoid scapulothoracic joint, the ellipsoid providing the most accurate results was a thorax-size ellipsoid fitting the area browsed by the scapula. Eventually, considering the high implementation costs of a multibody kinematics optimization, the segmental optimization could be considered as appropriate for scapular kinematics reconstruction.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"4 1","pages":"86 - 94"},"PeriodicalIF":0.0,"publicationDate":"2017-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2017.1405741","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41734095","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Three-dimensional kinematics of shoulder laxity examination and the relationship to clinical interpretation* 肩部松弛检查的三维运动学及其与临床解释的关系*
Q2 Medicine Pub Date : 2017-11-03 DOI: 10.1080/23335432.2017.1372217
Justin L. Staker, Amy E. Lelwica, P. Ludewig, Jonathan P. Braman
Abstract Understanding clinical test kinematics improves utility of exam techniques. The purposes of this study were as follows: (1) determine inter-examiner repeatability of translation magnitude for the Anterior/Posterior Drawer and Sulcus shoulder laxity tests; (2) describe the relationships between glenohumeral joint translations and subjective grades for each laxity test; and (3) describe the relationship of overall glenohumeral joint laxity to a composite subjective score from the three laxity tests. Eleven subjects with shoulder symptomology were examined with three laxity tests. Motion was tracked with electromagnetic sensors affixed to the humerus and scapula via transcortical pins. ICCs were calculated to determine repeatability of translation magnitudes between two examiners for each test. Descriptive statistics and regression analyses were performed for comparisons of single laxity test grades with translation magnitudes and for composite subjective laxity scores and overall translation across all three tests. Inter-examiner ICCs regarding kinematic repeatability were 0.87 for Anterior Drawer, 0.84 for the Sulcus test, and not calculable for the Posterior Drawer. No linear relationships between subjective grades of individual tests and translation magnitudes were found. The relationship of overall translation with the composite subjective score from all laxity tests was r2 = 0.75 (r = 0.86). Clinicians from different disciplines are capable of imparting similar translations during laxity tests. Single-test subjective laxity grades demonstrate large ranges of translation between subjects for the same grade. By combining results of three laxity tests, clinicians are capable of identifying the level of overall shoulder joint laxity in patients.
摘要了解临床测试运动学可以提高测试技术的实用性。本研究的目的如下:(1)确定前/后抽屉和Sulcus肩部松弛度测试的平移幅度的检查者间可重复性;(2) 描述每个松弛度测试的肩关节翻译和主观成绩之间的关系;以及(3)描述整个肩关节松弛度与来自三个松弛度测试的综合主观得分的关系。11名有肩部症状的受试者接受了三次松弛度测试。通过经皮钉将电磁传感器固定在肱骨和肩胛骨上,追踪运动。计算ICCs,以确定每次测试中两名检查者之间平移幅度的可重复性。进行描述性统计和回归分析,将单项松懈测试成绩与翻译量表进行比较,并对所有三项测试的综合主观松懈得分和整体翻译进行比较。检查者间关于前抽屉运动重复性的ICCs为0.87,Sulcus测试为0.84,后抽屉不可计算。个体测试的主观等级与翻译量之间没有线性关系。整体翻译与所有松懈测试的综合主观得分的关系为r2=0.75(r=0.86)。来自不同学科的临床医生能够在松懈测试中传授类似的翻译。单次测试的主观松懈等级表明,同一等级的科目之间的翻译范围很大。通过结合三种松弛度测试的结果,临床医生能够确定患者肩关节整体松弛度的水平。
{"title":"Three-dimensional kinematics of shoulder laxity examination and the relationship to clinical interpretation*","authors":"Justin L. Staker, Amy E. Lelwica, P. Ludewig, Jonathan P. Braman","doi":"10.1080/23335432.2017.1372217","DOIUrl":"https://doi.org/10.1080/23335432.2017.1372217","url":null,"abstract":"Abstract Understanding clinical test kinematics improves utility of exam techniques. The purposes of this study were as follows: (1) determine inter-examiner repeatability of translation magnitude for the Anterior/Posterior Drawer and Sulcus shoulder laxity tests; (2) describe the relationships between glenohumeral joint translations and subjective grades for each laxity test; and (3) describe the relationship of overall glenohumeral joint laxity to a composite subjective score from the three laxity tests. Eleven subjects with shoulder symptomology were examined with three laxity tests. Motion was tracked with electromagnetic sensors affixed to the humerus and scapula via transcortical pins. ICCs were calculated to determine repeatability of translation magnitudes between two examiners for each test. Descriptive statistics and regression analyses were performed for comparisons of single laxity test grades with translation magnitudes and for composite subjective laxity scores and overall translation across all three tests. Inter-examiner ICCs regarding kinematic repeatability were 0.87 for Anterior Drawer, 0.84 for the Sulcus test, and not calculable for the Posterior Drawer. No linear relationships between subjective grades of individual tests and translation magnitudes were found. The relationship of overall translation with the composite subjective score from all laxity tests was r2 = 0.75 (r = 0.86). Clinicians from different disciplines are capable of imparting similar translations during laxity tests. Single-test subjective laxity grades demonstrate large ranges of translation between subjects for the same grade. By combining results of three laxity tests, clinicians are capable of identifying the level of overall shoulder joint laxity in patients.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"4 1","pages":"77 - 85"},"PeriodicalIF":0.0,"publicationDate":"2017-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2017.1372217","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41684356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
System for the experimental evaluation of anthropomorphic hands. Application to a new 3D-printed prosthetic hand prototype 拟人手的实验评估系统。一种新型3D打印假手原型的应用
Q2 Medicine Pub Date : 2017-11-03 DOI: 10.1080/23335432.2017.1364666
Immaculada Llop-Harillo, A. Pérez-González
Abstract In the present study, we propose a new actuation device and protocol for testing the grasping performance of low-cost 3D-printed hand prototypes. The actuation device is connected to the forearm of a healthy user and allows him to use his thumb and fingers to control any prototype moved by up to six tendons attached to this device. The protocol includes grasping actions on 24 different objects using eight typical grasp types to obtain a grasping ability score and information about the coordination of motion among the fingers. This study also presents a new design for a low-cost 3D-printed prosthetic hand, called the IMMA hand. Preliminary tests were performed with the IMMA hand and the actuation device on two subjects, using the protocol, to assess the validity of the device for the experimental evaluation of hand prototypes in early design stages. The analysis of the results of these tests shows that the coordination of motions among fingers is quite similar for both subjects, indicating a similar control of the artificial hand. Index and ring finger motions are highly correlated in over half of the grasp actions performed for both subjects.
摘要在本研究中,我们提出了一种新的驱动装置和协议,用于测试低成本3D打印手原型的抓取性能。致动装置连接到健康用户的前臂,并允许他使用拇指和手指来控制由连接到该装置的多达六根肌腱移动的任何原型。该协议包括使用八种典型抓握类型对24个不同物体进行抓握动作,以获得抓握能力得分和关于手指之间运动协调的信息。这项研究还提出了一种低成本3D打印假手的新设计,称为IMMA手。使用该方案,用IMMA手和致动装置对两名受试者进行了初步测试,以评估该装置在早期设计阶段对手原型进行实验评估的有效性。对这些测试结果的分析表明,两名受试者手指之间的运动协调性非常相似,表明对假手的控制相似。食指和无名指的运动在两个受试者超过一半的抓握动作中高度相关。
{"title":"System for the experimental evaluation of anthropomorphic hands. Application to a new 3D-printed prosthetic hand prototype","authors":"Immaculada Llop-Harillo, A. Pérez-González","doi":"10.1080/23335432.2017.1364666","DOIUrl":"https://doi.org/10.1080/23335432.2017.1364666","url":null,"abstract":"Abstract In the present study, we propose a new actuation device and protocol for testing the grasping performance of low-cost 3D-printed hand prototypes. The actuation device is connected to the forearm of a healthy user and allows him to use his thumb and fingers to control any prototype moved by up to six tendons attached to this device. The protocol includes grasping actions on 24 different objects using eight typical grasp types to obtain a grasping ability score and information about the coordination of motion among the fingers. This study also presents a new design for a low-cost 3D-printed prosthetic hand, called the IMMA hand. Preliminary tests were performed with the IMMA hand and the actuation device on two subjects, using the protocol, to assess the validity of the device for the experimental evaluation of hand prototypes in early design stages. The analysis of the results of these tests shows that the coordination of motions among fingers is quite similar for both subjects, indicating a similar control of the artificial hand. Index and ring finger motions are highly correlated in over half of the grasp actions performed for both subjects.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"4 1","pages":"50 - 59"},"PeriodicalIF":0.0,"publicationDate":"2017-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2017.1364666","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49534085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
Normative kinematics of reaching and dexterity tasks: moving towards a quantitative baseline for Functional Capacity Evaluations (FCEs) 伸展和灵活性任务的规范运动学:迈向功能能力评估(FCE)的定量基线
Q2 Medicine Pub Date : 2017-11-03 DOI: 10.1080/23335432.2017.1326843
Angelica E. Lang, C. Dickerson
Abstract Purpose: This work generates a comprehensive description of upper extremity and torso kinematics of a healthy population during reaching and dexterity Functional Capacity Evaluation (FCE) tasks. Methods: Upper limb and torso kinematic data were collected from 30 young, healthy participants as they performed three common FCE tasks: repetitive reaching, fingertip dexterity, and hand and forearm dexterity. Kinematic profiles were created for all clinically relevant angles of the torso, shoulder, elbow, and wrist. Results: These provocative tasks require large ranges of motion and create high demand postures for the upper limb, specifically at the shoulder. Arm elevation was up to 90°, while humeral internal rotation of 25° was observed. Torso angles were typically below 30° from neutral and elbow flexion remained within 90°–120° for nearly all tasks. Wrist ulnar deviation ranged from 0° to 26° for both wrists. Conclusion: The normative data created in this investigation provide a description of healthy motion during reaching and dexterity tasks. These normative curves are the initial step towards understanding movement that would contraindicate return to work during an FCE. This work supports a future clinical goal of being able to identify persons at risk of further injury or disability if returned to work too early.
摘要目的:这项工作对健康人群在伸展和灵活性功能能力评估(FCE)任务中的上肢和躯干运动学进行了全面描述。方法:收集30名年轻健康参与者的上肢和躯干运动学数据,他们进行了三项常见的FCE任务:重复伸手、指尖灵活性以及手和前臂灵活性。为躯干、肩部、肘部和手腕的所有临床相关角度创建了运动学轮廓。结果:这些挑衅性的任务需要大幅度的运动,并对上肢,特别是肩部产生高要求的姿势。手臂抬高达90°,同时观察到肱骨内旋25°。躯干角度通常低于中性30°,几乎所有任务的肘部屈曲都保持在90°-120°之间。手腕尺侧偏斜范围为0°至26°。结论:本研究中创建的规范性数据提供了对伸展和灵活性任务中健康运动的描述。这些标准曲线是理解FCE期间禁止重返工作岗位的运动的第一步。这项工作支持了未来的临床目标,即如果过早返回工作岗位,能够识别出有进一步受伤或残疾风险的人。
{"title":"Normative kinematics of reaching and dexterity tasks: moving towards a quantitative baseline for Functional Capacity Evaluations (FCEs)","authors":"Angelica E. Lang, C. Dickerson","doi":"10.1080/23335432.2017.1326843","DOIUrl":"https://doi.org/10.1080/23335432.2017.1326843","url":null,"abstract":"Abstract Purpose: This work generates a comprehensive description of upper extremity and torso kinematics of a healthy population during reaching and dexterity Functional Capacity Evaluation (FCE) tasks. Methods: Upper limb and torso kinematic data were collected from 30 young, healthy participants as they performed three common FCE tasks: repetitive reaching, fingertip dexterity, and hand and forearm dexterity. Kinematic profiles were created for all clinically relevant angles of the torso, shoulder, elbow, and wrist. Results: These provocative tasks require large ranges of motion and create high demand postures for the upper limb, specifically at the shoulder. Arm elevation was up to 90°, while humeral internal rotation of 25° was observed. Torso angles were typically below 30° from neutral and elbow flexion remained within 90°–120° for nearly all tasks. Wrist ulnar deviation ranged from 0° to 26° for both wrists. Conclusion: The normative data created in this investigation provide a description of healthy motion during reaching and dexterity tasks. These normative curves are the initial step towards understanding movement that would contraindicate return to work during an FCE. This work supports a future clinical goal of being able to identify persons at risk of further injury or disability if returned to work too early.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"4 1","pages":"37 - 49"},"PeriodicalIF":0.0,"publicationDate":"2017-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2017.1326843","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42366619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Muscle activity of upper and lower trapezius and serratus anterior during unloaded and maximal loaded shoulder flexion and extension 无负荷和最大负荷肩屈伸时上斜方肌和前锯肌的肌肉活动
Q2 Medicine Pub Date : 2017-11-03 DOI: 10.1080/23335432.2017.1364668
M. Wochatz, Sophie Rabe, M. Wolter, T. Engel, Steffen Mueller, F. Mayer
Abstract Altered scapular muscle activity is mostly described under unloaded and submaximal loaded conditions in impingement patients. However, there is no clear evidence on muscle activity with respect to movement phases under maximum load in healthy subjects. Therefore, this study aimed to investigate scapular muscle activity under unloaded and maximum loaded isokinetic shoulder flexion and extension in regard to the movement phase. Fourteen adults performed unloaded (continuous passive motion [CPM]) as well as maximum loaded (concentric [CON], eccentric [ECC]) isokinetic shoulder flexion (Flex) and extension (Ext). Simultaneously, scapular muscle activity was measured by EMG. Root mean square was calculated for the whole ROM and four movement phases. Data were analyzed descriptively and by two-way repeated measures ANOVA. CPMFlex resulted in a linear increase of muscle activity for all muscles. Muscle activity during CONFlex and ECCFlex resulted in either constant activity levels or in an initial increase followed by a plateau in the second half of movement. CPMExt decreased with the progression of movement, whereas CONExt and ECCExt initially decreased and either levelled off or increased in the second half of movement. Scapular muscle activity of unloaded shoulder flexion and extension changed under maximum load showing increased activity levels and an altered pattern over the course of movement.
摘要撞击患者肩胛肌活动的改变主要是在无负荷和次最大负荷条件下描述的。然而,没有明确的证据表明健康受试者在最大负荷下的运动阶段的肌肉活动。因此,本研究旨在研究在无负荷和最大负荷的等速肩屈伸运动阶段肩胛肌的活动。14名成年人进行了无负荷(连续被动运动[CMP])以及最大负荷(同心[CON]、偏心[ECC])等速肩关节屈曲(Flex)和伸展(Ext)。同时,通过肌电图测量肩胛肌活动。计算整个ROM和四个运动阶段的均方根。数据采用描述性分析和双向重复测量方差分析。CPMFlex导致所有肌肉的肌肉活动呈线性增加。CONFlex和ECCFlex期间的肌肉活动导致活动水平保持不变,或者在运动的后半段出现最初的增加,然后出现平稳期。CPMExt随着运动的进行而降低,而CONExt和ECCExt最初降低,在运动的后半段趋于平稳或增加。肩关节无负荷屈伸的肩胛肌活动在最大负荷下发生变化,显示活动水平增加,运动过程中模式改变。
{"title":"Muscle activity of upper and lower trapezius and serratus anterior during unloaded and maximal loaded shoulder flexion and extension","authors":"M. Wochatz, Sophie Rabe, M. Wolter, T. Engel, Steffen Mueller, F. Mayer","doi":"10.1080/23335432.2017.1364668","DOIUrl":"https://doi.org/10.1080/23335432.2017.1364668","url":null,"abstract":"Abstract Altered scapular muscle activity is mostly described under unloaded and submaximal loaded conditions in impingement patients. However, there is no clear evidence on muscle activity with respect to movement phases under maximum load in healthy subjects. Therefore, this study aimed to investigate scapular muscle activity under unloaded and maximum loaded isokinetic shoulder flexion and extension in regard to the movement phase. Fourteen adults performed unloaded (continuous passive motion [CPM]) as well as maximum loaded (concentric [CON], eccentric [ECC]) isokinetic shoulder flexion (Flex) and extension (Ext). Simultaneously, scapular muscle activity was measured by EMG. Root mean square was calculated for the whole ROM and four movement phases. Data were analyzed descriptively and by two-way repeated measures ANOVA. CPMFlex resulted in a linear increase of muscle activity for all muscles. Muscle activity during CONFlex and ECCFlex resulted in either constant activity levels or in an initial increase followed by a plateau in the second half of movement. CPMExt decreased with the progression of movement, whereas CONExt and ECCExt initially decreased and either levelled off or increased in the second half of movement. Scapular muscle activity of unloaded shoulder flexion and extension changed under maximum load showing increased activity levels and an altered pattern over the course of movement.","PeriodicalId":52124,"journal":{"name":"International Biomechanics","volume":"4 1","pages":"68 - 76"},"PeriodicalIF":0.0,"publicationDate":"2017-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23335432.2017.1364668","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47231142","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
期刊
International Biomechanics
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1