Positron Emission Tomography 正电子发射断层扫描
Pub Date : 2020-04-24 DOI: 10.1201/b14282-14
P. Camici
{"title":"Positron Emission Tomography","authors":"P. Camici","doi":"10.1201/b14282-14","DOIUrl":"https://doi.org/10.1201/b14282-14","url":null,"abstract":"","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2020-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"65982665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mechanical impedance of layered tissue. 层状组织的机械阻抗。
Pub Date : 1997-01-01
H Oka, T Irie

The human body is a medium which consists of various tissues such as skin, fat, muscle and bone. Each of the tissues has their own biomechanical properties. We have measured biomechanical impedances by applying a random vibration (30-1000 Hz) to the layered model of human tissues to study the occurring mechanism of impedances measured at the skin surface. The data showed that the top tissue layer and the underlying layer both contribute to the impedance depending on the thickness of the top layer. The contribution of the underlying layer was clearer over the frequency range from 30 to 400 Hz. Quantitatively we found the following: The impedance measured at the surface was roughly expressed as the model which is connected in series by the impedances of the top and underlying tissues. The contribution of the underlying tissue decreased according to the increase of the thickness of the top tissue, and disappeared over a certain thickness (18 mm in this paper).

人体是由皮肤、脂肪、肌肉和骨骼等各种组织组成的介质。每种组织都有自己的生物力学特性。我们通过对人体组织分层模型施加随机振动(30-1000 Hz)来测量生物力学阻抗,以研究皮肤表面测量的阻抗的发生机制。数据表明,根据表层厚度的不同,表层和下层都对阻抗有贡献。在30至400赫兹的频率范围内,下垫层的贡献更为明显。在定量上,我们发现:表面测量的阻抗大致表示为顶部和底部组织阻抗串联的模型。下层组织的贡献随上层组织厚度的增加而减小,超过一定厚度(本文为18mm)后消失。
{"title":"Mechanical impedance of layered tissue.","authors":"H Oka,&nbsp;T Irie","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The human body is a medium which consists of various tissues such as skin, fat, muscle and bone. Each of the tissues has their own biomechanical properties. We have measured biomechanical impedances by applying a random vibration (30-1000 Hz) to the layered model of human tissues to study the occurring mechanism of impedances measured at the skin surface. The data showed that the top tissue layer and the underlying layer both contribute to the impedance depending on the thickness of the top layer. The contribution of the underlying layer was clearer over the frequency range from 30 to 400 Hz. Quantitatively we found the following: The impedance measured at the surface was roughly expressed as the model which is connected in series by the impedances of the top and underlying tissues. The contribution of the underlying tissue decreased according to the increase of the thickness of the top tissue, and disappeared over a certain thickness (18 mm in this paper).</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 Suppl ","pages":"1-4"},"PeriodicalIF":0.0,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20342331","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Guinea pig auditory nerve response triggered by a high density electrode array. 高密度电极阵列触发豚鼠听神经反应。
Pub Date : 1997-01-01
C N Jolly, B M Clopton, F A Spelman, S K Lineaweaver

The electrically evoked potential in the auditory nerve is measured when the cochlear is stimulated with a high density electrode array whose microcontacts (20 x 160 microns) are placed close to the nerve cells. Threshold range from 8 to 35 microA with the stimulating electrodes near the spiral ganglion cells. A multi-pole technique for restricting the spread of current with electrical stimulation of the cochlea is tested using neural recording in deafened guinea pigs. The ground based quadrupolar electrode driving configuration has thresholds for neural activation only slightly greater than monopolar stimulation when the electrode contacts are placed less than 50 microns from the neurons. During simultaneous stimulation the monopole and the ground based quadrupolar modes tend to generate similar growth functions (magnitude and latency). The electrode interactions are generally factorial, which means that the algebraic sum of the responses (magnitude growth functions) produced by 2 distinct electrodes is less than when the same 2 electrodes are stimulated simultaneously.

当耳蜗受到高密度电极阵列的刺激时,听神经中的电诱发电位被测量,该电极阵列的微触点(20 x 160微米)被放置在神经细胞附近。当刺激电极靠近螺旋神经节细胞时,阈值范围为8 ~ 35 microA。在耳聋的豚鼠中,利用神经记录技术测试了一种利用电刺激耳蜗来限制电流传播的多极技术。当电极接触距离神经元小于50微米时,地面四极电极驱动配置的神经激活阈值仅略高于单极刺激。在同时刺激时,单极模式和地面四极模式倾向于产生相似的生长函数(幅度和延迟)。电极相互作用通常是阶乘的,这意味着两个不同电极产生的响应(幅度增长函数)的代数和小于同时刺激相同的两个电极时。
{"title":"Guinea pig auditory nerve response triggered by a high density electrode array.","authors":"C N Jolly,&nbsp;B M Clopton,&nbsp;F A Spelman,&nbsp;S K Lineaweaver","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The electrically evoked potential in the auditory nerve is measured when the cochlear is stimulated with a high density electrode array whose microcontacts (20 x 160 microns) are placed close to the nerve cells. Threshold range from 8 to 35 microA with the stimulating electrodes near the spiral ganglion cells. A multi-pole technique for restricting the spread of current with electrical stimulation of the cochlea is tested using neural recording in deafened guinea pigs. The ground based quadrupolar electrode driving configuration has thresholds for neural activation only slightly greater than monopolar stimulation when the electrode contacts are placed less than 50 microns from the neurons. During simultaneous stimulation the monopole and the ground based quadrupolar modes tend to generate similar growth functions (magnitude and latency). The electrode interactions are generally factorial, which means that the algebraic sum of the responses (magnitude growth functions) produced by 2 distinct electrodes is less than when the same 2 electrodes are stimulated simultaneously.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 Suppl ","pages":"13-23"},"PeriodicalIF":0.0,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20342333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A new computerized control unit for small bone surgical instruments. 一种用于小型骨手术器械的新型计算机控制单元。
Pub Date : 1997-01-01
J G Neal, M J Cox, D B Drake, M A Hoard, J G Thacker, F H Watkins, R F Edlich

The SmartDrive console represents an important advance in small bone surgery because it monitors and coordinates the operation of its handpieces. The SmartDrive console has the following unique features: 1) a handpiece recognition system; 2) an instrument speed display; 3) a handpiece display and monitoring system; 4) a torque instrument control system; 5) a temperature monitoring system; 6) and an irrigation system. Mechanical performance studies have been undertaken that have validated the accuracy of the monitoring systems of the consoles. The consoles provided reliable recordings of the rotational speeds of their hi-speed drills. The MicroAire console automatically shuts off its power as the temperature increased to 110 degrees F (43 degrees C). In contrast, the Stryker Command 2 console has a limited monitoring system that can not alter the operation of the handpieces.

SmartDrive控制台代表了小型骨骼手术的重要进步,因为它可以监控和协调其手持设备的操作。SmartDrive控制台具有以下独特功能:1)手机识别系统;2)仪表速度显示;3)手机显示和监控系统;4)扭矩仪表控制系统;5)温度监测系统;6)和灌溉系统。已经进行了机械性能研究,验证了控制台监测系统的准确性。控制台提供了高速钻机转速的可靠记录。当温度上升到110华氏度(43摄氏度)时,MicroAire控制台会自动关闭电源。相比之下,Stryker Command 2控制台有一个有限的监控系统,不能改变手机的操作。
{"title":"A new computerized control unit for small bone surgical instruments.","authors":"J G Neal,&nbsp;M J Cox,&nbsp;D B Drake,&nbsp;M A Hoard,&nbsp;J G Thacker,&nbsp;F H Watkins,&nbsp;R F Edlich","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The SmartDrive console represents an important advance in small bone surgery because it monitors and coordinates the operation of its handpieces. The SmartDrive console has the following unique features: 1) a handpiece recognition system; 2) an instrument speed display; 3) a handpiece display and monitoring system; 4) a torque instrument control system; 5) a temperature monitoring system; 6) and an irrigation system. Mechanical performance studies have been undertaken that have validated the accuracy of the monitoring systems of the consoles. The consoles provided reliable recordings of the rotational speeds of their hi-speed drills. The MicroAire console automatically shuts off its power as the temperature increased to 110 degrees F (43 degrees C). In contrast, the Stryker Command 2 console has a limited monitoring system that can not alter the operation of the handpieces.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 Suppl ","pages":"25-9"},"PeriodicalIF":0.0,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20342334","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Non-invasive assessment of systemic elastic behaviour in hypertensive patients: analysis of possible determinants. 高血压患者全身弹性行为的无创评估:可能的决定因素分析。
Pub Date : 1997-01-01
A I Christen, R A Sánchez, H P Baglivo, R L Armentano, M R Risk, E I Cabrera Fischer

Knowledge about the viscoelastic behaviour of the arterial wall has been proved to have physiological importance and clinical usage. Our purpose was to study the changes of the systemic arterial wall's elastic properties non-invasively, in patients with established essential and with borderline hypertension, and to evaluate its possible determinants. Three groups of normotensive, borderline and established essential hypertensive patients were evaluated. Arterial pulse wave velocity (PWV) was measured and arterial compliance (Cm) was derived in all patients. Pulse wave velocity was obtained from the pressure values of digitized carotid and radial arteries. Arterial compliance (Cm = dD/dP with P pressure and D diameter) was calculated using a formula derived from the Bramwell and Hill equation: Cm = (1,334 x D)/(2 rho x PWV2), where for D humeral diameter was used as measured by high resolution echograph, and rho is the blood density (rho = 1.06). Pulse wave velocity was significantly higher in established essential hypertensive patients with respect to normotensive patients (p < 0.05). Arterial compliance was significantly diminished in established and in borderline hypertensive patients with respect to normotensive patients (p < 0.05), which implies early alterations in hypertensive cardiovascular disease. Multiple regression analysis of the cofactors showed that age and diastolic pressure are independent determinants of Cm. Impairment of the arterial wall's intrinsic elastic properties was demonstrated in established essential hypertension, independent of age and diastolic pressure.

关于动脉壁粘弹性行为的知识已被证明具有生理重要性和临床应用。我们的目的是研究原发性和边缘性高血压患者全身动脉壁弹性特性的无创变化,并评估其可能的决定因素。对三组正常、交界性和已确定的原发性高血压患者进行评估。测量所有患者的动脉脉搏波速度(PWV)和动脉顺应性(Cm)。脉冲波速度由数字化的颈动脉和桡动脉的压力值得到。根据Bramwell和Hill方程计算动脉顺应性(Cm = dD/dP, P压和D径):Cm = (1,334 x D)/(2 rho x PWV2),其中D肱部直径采用高分辨率超声测量,rho为血液密度(rho = 1.06)。原发性高血压患者的脉搏波速度明显高于正常高血压患者(p < 0.05)。与正常高血压患者相比,既有高血压患者和交界性高血压患者的动脉顺应性显著降低(p < 0.05),这意味着高血压心血管疾病的早期改变。辅助因素的多元回归分析显示,年龄和舒张压是Cm的独立决定因素。动脉壁固有弹性特性的损害在原发性高血压中得到证实,与年龄和舒张压无关。
{"title":"Non-invasive assessment of systemic elastic behaviour in hypertensive patients: analysis of possible determinants.","authors":"A I Christen,&nbsp;R A Sánchez,&nbsp;H P Baglivo,&nbsp;R L Armentano,&nbsp;M R Risk,&nbsp;E I Cabrera Fischer","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Knowledge about the viscoelastic behaviour of the arterial wall has been proved to have physiological importance and clinical usage. Our purpose was to study the changes of the systemic arterial wall's elastic properties non-invasively, in patients with established essential and with borderline hypertension, and to evaluate its possible determinants. Three groups of normotensive, borderline and established essential hypertensive patients were evaluated. Arterial pulse wave velocity (PWV) was measured and arterial compliance (Cm) was derived in all patients. Pulse wave velocity was obtained from the pressure values of digitized carotid and radial arteries. Arterial compliance (Cm = dD/dP with P pressure and D diameter) was calculated using a formula derived from the Bramwell and Hill equation: Cm = (1,334 x D)/(2 rho x PWV2), where for D humeral diameter was used as measured by high resolution echograph, and rho is the blood density (rho = 1.06). Pulse wave velocity was significantly higher in established essential hypertensive patients with respect to normotensive patients (p < 0.05). Arterial compliance was significantly diminished in established and in borderline hypertensive patients with respect to normotensive patients (p < 0.05), which implies early alterations in hypertensive cardiovascular disease. Multiple regression analysis of the cofactors showed that age and diastolic pressure are independent determinants of Cm. Impairment of the arterial wall's intrinsic elastic properties was demonstrated in established essential hypertension, independent of age and diastolic pressure.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 Suppl ","pages":"5-11"},"PeriodicalIF":0.0,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20342332","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Medical expert system on fuzzy analog ganglionar lattices: explication and prospection based on sensitivity. 模糊模拟神经节格医学专家系统:基于灵敏度的解释与展望。
Pub Date : 1996-01-01
C A Holzmann, M San Martín

A reasoning method to explicate the conclusions-a posteriori- and to prospect for the next test-a priori-applied to medical expert systems based on fuzzy analog ganglionar lattices is presented. This method is founded on the sensitivity criterion of the consequent respect to the antecedents. It proves to be suited for problems of any complexity, specially when they are formulated on well-established intermediate concepts, such as syndromes, clinical finding, laboratory procedures, etc., as is usually the case in medical procedures. This type of expert system uses the structural properties of the ganglionar lattice to produce explications for its conclusions at different levels of abstraction, and to an arbitrary, but fixed, explicative degree. A measure to evaluate the consequent's achieved preciseness (certainty) is also supplied. A full example of application in the diagnosis of cardiac insufficiency with hypertensive myocardiopathy is shown, and a computational implementation of this analog procedure is described. Finally, the reasoning methods for explicating and prospecting are discussed.

提出了一种基于模糊模拟神经节格的医学专家系统的推理方法,用于解释结论(后验)和展望下一个测试(优先级)。该方法建立在结果相对于前因式的敏感性准则的基础上。事实证明,它适用于任何复杂的问题,特别是当这些问题是根据公认的中间概念制定的,如综合征、临床发现、实验室程序等,这通常是医疗程序中的情况。这种类型的专家系统利用神经节格的结构特性,在不同的抽象层次上对其结论进行解释,并达到任意但固定的解释程度。还提供了一种评价结果所达到的精确性(确定性)的方法。在诊断高血压心肌病心功能不全的一个完整的例子被显示,并描述了这个模拟过程的计算实现。最后讨论了找矿的推理方法。
{"title":"Medical expert system on fuzzy analog ganglionar lattices: explication and prospection based on sensitivity.","authors":"C A Holzmann,&nbsp;M San Martín","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>A reasoning method to explicate the conclusions-a posteriori- and to prospect for the next test-a priori-applied to medical expert systems based on fuzzy analog ganglionar lattices is presented. This method is founded on the sensitivity criterion of the consequent respect to the antecedents. It proves to be suited for problems of any complexity, specially when they are formulated on well-established intermediate concepts, such as syndromes, clinical finding, laboratory procedures, etc., as is usually the case in medical procedures. This type of expert system uses the structural properties of the ganglionar lattice to produce explications for its conclusions at different levels of abstraction, and to an arbitrary, but fixed, explicative degree. A measure to evaluate the consequent's achieved preciseness (certainty) is also supplied. A full example of application in the diagnosis of cardiac insufficiency with hypertensive myocardiopathy is shown, and a computational implementation of this analog procedure is described. Finally, the reasoning methods for explicating and prospecting are discussed.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 4","pages":"195-203"},"PeriodicalIF":0.0,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20059396","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization. 等离子体聚合四氟乙烯处理NiTi形状记忆合金。物理化学和电化学表征。
Pub Date : 1996-01-01
L H Yahia, S Lombardi, D Piron, J E Klemberg-Sapieha, M R Wertheimer

NiTi alloy specimens were plasma cleaned and then coated with a thin film of plasma-polymerized tetrafluoroethylene (TFE) in a Radio-Frequency reactor. The corrosion protection provided by these films was studied by potentiodynamic tests performed in Hank's physiological solution. Surface properties which determine biocompatibility were characterized by X-ray photoelectron spectroscopy (XPS). The results showed that the surface of untreated NiTi was mostly composed by oxygen, carbon, titanium oxide (TiO2) with traces of nickel oxides (NiO and Ni2O3) and metallic Ni. The passivity of untreated NiTi was found to be unstable in the simulated human body media. After plasma treatment, the NiTi surface contained only carbon and fluor. The plasma-polymerized thin film was found to stabilize the NiTi passivity and to increase its pitting potential. This treatment provides a good protection against dissolution of nickel from NiTi alloys.

对镍钛合金试样进行等离子体清洗,然后在射频反应器中涂覆一层等离子体聚合四氟乙烯薄膜。在汉克的生理溶液中进行了电位动力学试验,研究了这些薄膜的防腐蚀作用。用x射线光电子能谱(XPS)表征了决定生物相容性的表面性质。结果表明:未经处理的NiTi表面主要由氧、碳、氧化钛(TiO2)组成,并含有微量的氧化镍(NiO和Ni2O3)和金属镍。未经处理的NiTi在模拟人体介质中的被动性不稳定。等离子体处理后,镍钛表面仅含碳和氟。等离子体聚合薄膜稳定了镍钛的钝化性能,提高了其点蚀电位。这种处理可以很好地防止镍钛合金中镍的溶解。
{"title":"NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.","authors":"L H Yahia,&nbsp;S Lombardi,&nbsp;D Piron,&nbsp;J E Klemberg-Sapieha,&nbsp;M R Wertheimer","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>NiTi alloy specimens were plasma cleaned and then coated with a thin film of plasma-polymerized tetrafluoroethylene (TFE) in a Radio-Frequency reactor. The corrosion protection provided by these films was studied by potentiodynamic tests performed in Hank's physiological solution. Surface properties which determine biocompatibility were characterized by X-ray photoelectron spectroscopy (XPS). The results showed that the surface of untreated NiTi was mostly composed by oxygen, carbon, titanium oxide (TiO2) with traces of nickel oxides (NiO and Ni2O3) and metallic Ni. The passivity of untreated NiTi was found to be unstable in the simulated human body media. After plasma treatment, the NiTi surface contained only carbon and fluor. The plasma-polymerized thin film was found to stabilize the NiTi passivity and to increase its pitting potential. This treatment provides a good protection against dissolution of nickel from NiTi alloys.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 4","pages":"187-93"},"PeriodicalIF":0.0,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20059354","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of a new external condom catheter system. 一种新型外套导管系统的评价。
Pub Date : 1996-01-01
A J Gear, W D Nguyen, M A Bealle, R F Edlich

The purpose of this study was to perform a biomechanical performance study and a clinical trial on a new external condom catheter system. The biomechanical performance study demonstrated that the vented connector failed following exposure to urine for 14 days. In addition, angulation of the inlet adapter of anti-reflux valve of the urinary leg bag to an angle of 35 degrees (+/-5 degrees) caused complete obstruction of urinary flow. A clinical trial of the new condom catheter with its inner flap revealed twisting of the catheter that interrupted urinary flow in four of ten patients. This catheter twisting was not observed in condom catheters without inner flaps. Furthermore, this new system is not easily applied or removed by patients with neurosensory deficits or musculoskeletal weakness. Design modifications of the vent within the connection tubing, the anti-reflux valve in the collection bag, the condom catheter with its inner flap, as well as the leg bag attachments should remarkably improve the performance of this new urinary drainage system.

本研究的目的是对一种新型外套导管系统进行生物力学性能研究和临床试验。生物力学性能研究表明,通气接头暴露于尿液中14天后失效。另外,尿腿袋防反流阀进口接头成角度为35度(+/-5度),造成尿流完全阻塞。一项对带有内瓣的新型避孕套导尿管的临床试验显示,在10名患者中,有4名患者的导尿管扭曲导致尿流中断。在没有内瓣的避孕套导管中没有观察到这种导管扭转。此外,这种新系统不容易被神经感觉缺陷或肌肉骨骼无力的患者应用或移除。对连接管内的通风口、收集袋内的抗反流阀、带内瓣的避孕套导管以及腿袋附件的设计修改应能显著改善这种新型泌尿引流系统的性能。
{"title":"Evaluation of a new external condom catheter system.","authors":"A J Gear,&nbsp;W D Nguyen,&nbsp;M A Bealle,&nbsp;R F Edlich","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The purpose of this study was to perform a biomechanical performance study and a clinical trial on a new external condom catheter system. The biomechanical performance study demonstrated that the vented connector failed following exposure to urine for 14 days. In addition, angulation of the inlet adapter of anti-reflux valve of the urinary leg bag to an angle of 35 degrees (+/-5 degrees) caused complete obstruction of urinary flow. A clinical trial of the new condom catheter with its inner flap revealed twisting of the catheter that interrupted urinary flow in four of ten patients. This catheter twisting was not observed in condom catheters without inner flaps. Furthermore, this new system is not easily applied or removed by patients with neurosensory deficits or musculoskeletal weakness. Design modifications of the vent within the connection tubing, the anti-reflux valve in the collection bag, the condom catheter with its inner flap, as well as the leg bag attachments should remarkably improve the performance of this new urinary drainage system.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 4","pages":"181-5"},"PeriodicalIF":0.0,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20059393","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluation of VoiceType Dictation for Windows for the radiologist. 放射科医师Windows语音听写的评价。
Pub Date : 1996-01-01
N J Zemmel, S M Park, E J Maurer, L F Leslie, R F Edlich

The accuracy of the radiology vocabulary domain of the IBM VoiceType Dictation for Windows speech recognition system for use in a clinical setting was evaluated. Six men and one woman dictated a case report under several conditions. The impact of vocabulary domain, microphone position, personal enrollment, and background noise were assessed. The dictations were exported to Microsoft Word 6.0, printed, and graded for accuracy. The data were expressed as a percentage correct. The enrollment and training processes took an average of 5 hours to complete. The accuracy of VoiceType Dictation was significantly reduced by speech volume and background noise level so that it could not be used to dictate clinical information accurately in a hospital setting. Although IBM's VoiceType Dictation with the radiology vocabulary domain has improved speech recognition, it is not a reliable dictation system for accurate and efficient clinical dictation in a hospital setting.

评估了用于临床环境的IBM VoiceType Dictation for Windows语音识别系统的放射学词汇域的准确性。六名男子和一名女子在几种情况下口授了一份病例报告。评估了词汇域、麦克风位置、个人登记和背景噪音的影响。听写导出到microsoftword6.0,打印出来,并对准确性进行分级。数据以正确率表示。注册和培训过程平均需要5个小时才能完成。语音类型听写的准确性受到语音音量和背景噪声水平的显著降低,因此无法在医院环境中准确地口述临床信息。尽管IBM的带有放射学词汇域的VoiceType听写改进了语音识别,但它并不是一个可靠的听写系统,无法在医院环境中进行准确和高效的临床听写。
{"title":"Evaluation of VoiceType Dictation for Windows for the radiologist.","authors":"N J Zemmel,&nbsp;S M Park,&nbsp;E J Maurer,&nbsp;L F Leslie,&nbsp;R F Edlich","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The accuracy of the radiology vocabulary domain of the IBM VoiceType Dictation for Windows speech recognition system for use in a clinical setting was evaluated. Six men and one woman dictated a case report under several conditions. The impact of vocabulary domain, microphone position, personal enrollment, and background noise were assessed. The dictations were exported to Microsoft Word 6.0, printed, and graded for accuracy. The data were expressed as a percentage correct. The enrollment and training processes took an average of 5 hours to complete. The accuracy of VoiceType Dictation was significantly reduced by speech volume and background noise level so that it could not be used to dictate clinical information accurately in a hospital setting. Although IBM's VoiceType Dictation with the radiology vocabulary domain has improved speech recognition, it is not a reliable dictation system for accurate and efficient clinical dictation in a hospital setting.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 4","pages":"177-80"},"PeriodicalIF":0.0,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20059520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Using movement parallax for 3D laparoscopy. 利用运动视差进行三维腹腔镜检查。
Pub Date : 1996-01-01
F A Voorhorst, K J Overbeeke, G J Smets

The lack of depth perception hampers the surgeon during laparoscopic operation. Laparoscopes usually are monocular, but binocular ones are currently available. Depth perception, however, does not exclusively rely on binocular disparity. An observer, with only one eye, who is able to move that eye, obtains the same information as an observer who has two eyes. This principle of movement parallax can be applied to laparoscopy by coupling the head movements of the surgeon to the motions of the tip of the laparoscope. In an experiment we investigated if this principle is applicable to laparoscopy. Two groups of testees with no background in surgery were used. The first group was assisted by movement parallax, the second group was viewing a static image. Both groups of testees had to perform an exploration and a manipulation task. Since the amount of space for camera motion within the laparoscope is limited, implementation potential depends on the amount of movements that will be made by the observer. Therefore the movements of the observer performing the exploration task were registered and analysed. Results of the experiment indicate the advantage of movement parallax for the exploration task (performance increases by factor 2 while using only 30% more time) but not for the manipulation task. The analysis of the movements indicates that small movements are sufficient for implementation. Based on these results we concluded that movement parallax is applicable to laparoscopy.

深度感知能力的缺乏阻碍了外科医生进行腹腔镜手术。腹腔镜通常是单目的,但目前也有双目的。然而,深度感知并不完全依赖于双眼的视差。一个只有一只眼睛的观察者能够移动这只眼睛,他得到的信息和一个有两只眼睛的观察者是一样的。通过将外科医生的头部运动与腹腔镜尖端运动耦合,运动视差原理可以应用于腹腔镜检查。在一项实验中,我们研究了这一原理是否适用于腹腔镜检查。两组没有外科背景的被试者被使用。第一组使用运动视差辅助,第二组使用静态图像辅助。两组测试者都必须完成探索和操作任务。由于摄像机在腹腔镜内的运动空间是有限的,因此实现的潜力取决于观察者将做出的运动量。因此,执行勘探任务的观察者的运动被记录和分析。实验结果表明,运动视差在探索任务中具有优势(仅用30%的时间就能使性能提高2倍),而在操作任务中则没有优势。对动作的分析表明,小动作就足够了。基于这些结果,我们认为运动视差在腹腔镜检查中是适用的。
{"title":"Using movement parallax for 3D laparoscopy.","authors":"F A Voorhorst,&nbsp;K J Overbeeke,&nbsp;G J Smets","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The lack of depth perception hampers the surgeon during laparoscopic operation. Laparoscopes usually are monocular, but binocular ones are currently available. Depth perception, however, does not exclusively rely on binocular disparity. An observer, with only one eye, who is able to move that eye, obtains the same information as an observer who has two eyes. This principle of movement parallax can be applied to laparoscopy by coupling the head movements of the surgeon to the motions of the tip of the laparoscope. In an experiment we investigated if this principle is applicable to laparoscopy. Two groups of testees with no background in surgery were used. The first group was assisted by movement parallax, the second group was viewing a static image. Both groups of testees had to perform an exploration and a manipulation task. Since the amount of space for camera motion within the laparoscope is limited, implementation potential depends on the amount of movements that will be made by the observer. Therefore the movements of the observer performing the exploration task were registered and analysed. Results of the experiment indicate the advantage of movement parallax for the exploration task (performance increases by factor 2 while using only 30% more time) but not for the manipulation task. The analysis of the movements indicates that small movements are sufficient for implementation. Based on these results we concluded that movement parallax is applicable to laparoscopy.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 4","pages":"211-8"},"PeriodicalIF":0.0,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"20059357","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
Medical progress through technology
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1