Technical Tips for Endovascular Aortic Repair Using the Gore Excluder Abdominal Stent-Graft: Endo-Wedge Technique and Scrum Technique 血管内主动脉瓣修复的技术提示:血管内楔形技术和Scrum技术
Pub Date : 2014-01-27 DOI: 10.2174/1874347101408010008
T. Banno, R. Kato*, Ryota Hanaoka, Hokuto Akamatsu, K. Kaneko, H. Toyama
s: When performing endovascular aortic repair (EVAR) procedures, clinicians sometimes encounter cases in which the indications for EVAR are beyond the instruction for use (IFU). In EVAR, proximal neck fixation is the most important factor. This report describes several techniques and tips for EVAR in cases presenting with a difficult short neck or angled neck, especially when using the Gore Excluder. Endo-wedge techniques (EWT), including non-sheathassisted EWT with sheath-assisted strategies, are presented. We describe the scrum technique, which is a special procedure that is only feasible when using the Gore Excluder. In this technique, intentional wire bending around the proximal neck portion occurs by pushing from both sides of the guidewire. This technique is applicable in cases with a sharply angled neck. The scrum with EWT is a more precise strategy for cases with a short or angled neck. Other troublesome cases include limb occlusion caused by weak points in the Gore Excluder® body and legs. The very rare complication of stent-graft collapse is also reviewed.
5:在进行血管内主动脉修复(EVAR)手术时,临床医生有时会遇到EVAR的适应症超出使用说明书(IFU)的情况。在EVAR中,近端颈部固定是最重要的因素。本报告介绍了几种EVAR的技术和技巧,特别是在出现困难的短颈或斜颈的情况下,特别是在使用Gore排除器时。介绍了内楔技术(EWT),包括具有鞘辅助策略的非鞘辅助EWT。我们描述了scrum技术,这是一种特殊的程序,只有在使用Gore exclender时才可行。在这种技术中,通过从导丝的两侧推动,导丝在近端颈部部分周围发生有意的弯曲。这种方法适用于颈部角度较陡的情况。对于颈部较短或有角度的情况,EWT的争抢是一种更精确的策略。其他麻烦的情况包括肢体闭塞造成的戈尔排除®身体和腿部的弱点。本文还对支架塌陷的罕见并发症进行了综述。
{"title":"Technical Tips for Endovascular Aortic Repair Using the Gore Excluder Abdominal Stent-Graft: Endo-Wedge Technique and Scrum Technique","authors":"T. Banno, R. Kato*, Ryota Hanaoka, Hokuto Akamatsu, K. Kaneko, H. Toyama","doi":"10.2174/1874347101408010008","DOIUrl":"https://doi.org/10.2174/1874347101408010008","url":null,"abstract":"s: When performing endovascular aortic repair (EVAR) procedures, clinicians sometimes encounter cases in which the indications for EVAR are beyond the instruction for use (IFU). In EVAR, proximal neck fixation is the most important factor. This report describes several techniques and tips for EVAR in cases presenting with a difficult short neck or angled neck, especially when using the Gore Excluder. Endo-wedge techniques (EWT), including non-sheathassisted EWT with sheath-assisted strategies, are presented. We describe the scrum technique, which is a special procedure that is only feasible when using the Gore Excluder. In this technique, intentional wire bending around the proximal neck portion occurs by pushing from both sides of the guidewire. This technique is applicable in cases with a sharply angled neck. The scrum with EWT is a more precise strategy for cases with a short or angled neck. Other troublesome cases include limb occlusion caused by weak points in the Gore Excluder® body and legs. The very rare complication of stent-graft collapse is also reviewed.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"30 1","pages":"8-21"},"PeriodicalIF":0.0,"publicationDate":"2014-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74562174","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
On the temporal fidelity of nonlinear inverse reconstructions for real- time MRI – The motion challenge. 实时MRI非线性逆重建的时间保真度——运动挑战。
Pub Date : 2014-01-23 DOI: 10.2174/1874347101408010001
J. Frahm, Sebastian Schätz, Markus Untenberger, Shuo Zhang, Dirk Voit, K. Merboldt, J. Sohns, J. Lotz, M. Uecker
Purpose: To evaluate the temporal accuracy of a self-consistent nonlinear inverse reconstruction method (NLINV) for real-time MRI using highly undersampled radial gradient-echo sequences and to present an open source framework for the motion assessment of real-time MRI methods. Methods: Serial image reconstructions by NLINV combine a joint estimation of individual frames and corresponding coil sensitivities with temporal regularization to a preceding frame. The temporal fidelity of the method was determined with a phantom consisting of water-filled tubes rotating at defined angular velocity. The conditions tested correspond to real- time cardiac MRI using SSFP contrast at 1.5 T (40 ms resolution) and T1 contrast at 3.0 T (33 ms and 18 ms resolution). In addition, the performance of a post-processing temporal median filter was evaluated. Results: NLINV reconstructions without temporal filtering yield accurate estimations as long as the speed of a small moving object corresponds to a spatial displacement during the acquisition of a single frame which is smaller than the object itself. Faster movements may lead to geometric distortions. For small objects moving at high velocity, a median filter may severely compromise the spatiotemporal accuracy. Conclusion: NLINV reconstructions offer excellent temporal fidelity as long as the image acquisition time is short enough to adequately sample ("freeze") the object movement. Temporal filtering should be applied with caution. The motion framework emerges as a valuable tool for the evaluation of real-time MRI methods.
目的:利用高度欠采样的径向梯度回波序列评估实时MRI自洽非线性逆重建方法(NLINV)的时间精度,并为实时MRI方法的运动评估提供一个开源框架。方法:利用NLINV方法对序列图像进行重建,将单个帧和相应线圈灵敏度的联合估计与前一帧的时间正则化相结合。该方法的时间保真度是用一个由以规定角速度旋转的装满水的管组成的幻影来确定的。所测试的条件对应于实时心脏MRI,使用1.5 T (40 ms分辨率)的SSFP对比度和3.0 T (33 ms和18 ms分辨率)的T1对比度。此外,还对后处理时间中值滤波器的性能进行了评价。结果:在获取比物体本身小的单帧图像时,只要运动物体的速度对应于空间位移,没有时间滤波的NLINV重建就能得到准确的估计。更快的运动可能导致几何扭曲。对于高速运动的小物体,中值滤波会严重影响其时空精度。结论:只要图像采集时间足够短,足以充分采样(“冻结”)物体运动,NLINV重建就能提供出色的时间保真度。时间过滤应该谨慎使用。运动框架成为评估实时MRI方法的一个有价值的工具。
{"title":"On the temporal fidelity of nonlinear inverse reconstructions for real- time MRI – The motion challenge.","authors":"J. Frahm, Sebastian Schätz, Markus Untenberger, Shuo Zhang, Dirk Voit, K. Merboldt, J. Sohns, J. Lotz, M. Uecker","doi":"10.2174/1874347101408010001","DOIUrl":"https://doi.org/10.2174/1874347101408010001","url":null,"abstract":"Purpose: To evaluate the temporal accuracy of a self-consistent nonlinear inverse reconstruction method (NLINV) for real-time MRI using highly undersampled radial gradient-echo sequences and to present an open source framework for the motion assessment of real-time MRI methods. Methods: Serial image reconstructions by NLINV combine a joint estimation of individual frames and corresponding coil sensitivities with temporal regularization to a preceding frame. The temporal fidelity of the method was determined with a phantom consisting of water-filled tubes rotating at defined angular velocity. The conditions tested correspond to real- time cardiac MRI using SSFP contrast at 1.5 T (40 ms resolution) and T1 contrast at 3.0 T (33 ms and 18 ms resolution). In addition, the performance of a post-processing temporal median filter was evaluated. Results: NLINV reconstructions without temporal filtering yield accurate estimations as long as the speed of a small moving object corresponds to a spatial displacement during the acquisition of a single frame which is smaller than the object itself. Faster movements may lead to geometric distortions. For small objects moving at high velocity, a median filter may severely compromise the spatiotemporal accuracy. Conclusion: NLINV reconstructions offer excellent temporal fidelity as long as the image acquisition time is short enough to adequately sample (\"freeze\") the object movement. Temporal filtering should be applied with caution. The motion framework emerges as a valuable tool for the evaluation of real-time MRI methods.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"56 1","pages":"1-7"},"PeriodicalIF":0.0,"publicationDate":"2014-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80690259","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 47
Interactive 3D Analysis of Blood Vessel Trees and Collateral Vessel Volumes in Magnetic Resonance Angiograms in the Mouse Ischemic Hindlimb Model. 小鼠后肢缺血模型磁共振血管成像血管树和侧支血管体积的交互式三维分析。
Pub Date : 2013-10-31 DOI: 10.2174/1874347101307010019
Peter C Marks, Marilena Preda, Terry Henderson, Lucy Liaw, Volkhard Lindner, Robert E Friesel, Ilka M Pinz

The quantitative analysis of blood vessel volumes from magnetic resonance angiograms (MRA) or μCT images is difficult and time-consuming. This fact, when combined with a study that involves multiple scans of multiple subjects, can represent a significant portion of research time. In order to enhance analysis options and to provide an automated and fast analysis method, we developed a software plugin for the ImageJ and Fiji image processing frameworks that enables the quick and reproducible volume quantification of blood vessel segments. The novel plugin named Volume Calculator (VolCal), accepts any binary (thresholded) image and produces a three-dimensional schematic representation of the vasculature that can be directly manipulated by the investigator. Using MRAs of the mouse hindlimb ischemia model, we demonstrate quick and reproducible blood vessel volume calculations with 95 - 98% accuracy. In clinical settings this software may enhance image interpretation and the speed of data analysis and thus enhance intervention decisions for example in peripheral vascular disease or aneurysms. In summary, we provide a novel, fast and interactive quantification of blood vessel volumes for single blood vessels or sets of vessel segments with particular focus on collateral formation after an ischemic insult.

从磁共振血管成像(MRA)或μCT图像中定量分析血管体积是困难且耗时的。这一事实,当与涉及多个受试者的多次扫描的研究相结合时,可以代表研究时间的很大一部分。为了增加分析选项并提供自动化和快速的分析方法,我们为ImageJ和Fiji图像处理框架开发了一个软件插件,使血管段的体积定量能够快速和可重复。新的插件名为体积计算器(VolCal),接受任何二进制(阈值)图像,并产生血管系统的三维原理图表示,可以由研究者直接操作。利用小鼠后肢缺血模型的核磁共振成像,我们展示了快速和可重复的血管体积计算,准确率为95 - 98%。在临床环境中,该软件可以提高图像解释和数据分析的速度,从而提高诸如周围血管疾病或动脉瘤的干预决策。总之,我们提供了一种新颖、快速和互动的血管体积量化方法,用于单个血管或血管段集,特别关注缺血损伤后侧枝的形成。
{"title":"Interactive 3D Analysis of Blood Vessel Trees and Collateral Vessel Volumes in Magnetic Resonance Angiograms in the Mouse Ischemic Hindlimb Model.","authors":"Peter C Marks,&nbsp;Marilena Preda,&nbsp;Terry Henderson,&nbsp;Lucy Liaw,&nbsp;Volkhard Lindner,&nbsp;Robert E Friesel,&nbsp;Ilka M Pinz","doi":"10.2174/1874347101307010019","DOIUrl":"https://doi.org/10.2174/1874347101307010019","url":null,"abstract":"<p><p>The quantitative analysis of blood vessel volumes from magnetic resonance angiograms (MRA) or μCT images is difficult and time-consuming. This fact, when combined with a study that involves multiple scans of multiple subjects, can represent a significant portion of research time. In order to enhance analysis options and to provide an automated and fast analysis method, we developed a software plugin for the ImageJ and Fiji image processing frameworks that enables the quick and reproducible volume quantification of blood vessel segments. The novel plugin named Volume Calculator (VolCal), accepts any binary (thresholded) image and produces a three-dimensional schematic representation of the vasculature that can be directly manipulated by the investigator. Using MRAs of the mouse hindlimb ischemia model, we demonstrate quick and reproducible blood vessel volume calculations with 95 - 98% accuracy. In clinical settings this software may enhance image interpretation and the speed of data analysis and thus enhance intervention decisions for example in peripheral vascular disease or aneurysms. In summary, we provide a novel, fast and interactive quantification of blood vessel volumes for single blood vessels or sets of vessel segments with particular focus on collateral formation after an ischemic insult.</p>","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"7 ","pages":"19-27"},"PeriodicalIF":0.0,"publicationDate":"2013-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3929959/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"32150733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
A Combined Fractal and Wavelet Angiography Image Compression Approach 一种分形和小波联合血管造影图像压缩方法
Pub Date : 2013-09-27 DOI: 10.2174/1874347101307010009
A. Al-Fahoum, B. Harb
In this paper, a combined Fractal and Wavelet (CFW) compression algorithm targeting x-ray angiogram images is proposed. Initially, the image is decomposed using wavelet transform. The smoothness of the low frequency part of the image appears as an approximation image with higher self similarities, therefore, it is coded using a fractal coding technique. However, the rest of the image is coded using an adaptive wavelet thresholding technique. This model is implemented and its performance is compared with best performances of the available published algorithms. A data set containing 1000 x-ray angiograms is used to study the performance of the algorithm. A minimum compression ratio of 30 with a peak signal to noise ratio (PSNR) of 36 dB and percent diameter stenosis deviation of (<0.2%) was achieved. Results demonstrate the effectiveness of the proposed technique in obtaining a diagnostic quality of reconstructed images at very low bit rates.
本文提出了一种针对x射线血管造影图像的分形和小波组合压缩算法。首先用小波变换对图像进行分解。图像低频部分的平滑度表现为具有较高自相似度的近似图像,因此采用分形编码技术对其进行编码。但是,图像的其余部分使用自适应小波阈值技术进行编码。实现了该模型,并将其性能与现有已发表算法的最佳性能进行了比较。用包含1000张x射线血管图像的数据集来研究该算法的性能。最小压缩比为30,峰值信噪比(PSNR)为36 dB,直径狭窄偏差百分比(<0.2%)。结果表明,所提出的技术在获得诊断质量的重建图像在非常低的比特率的有效性。
{"title":"A Combined Fractal and Wavelet Angiography Image Compression Approach","authors":"A. Al-Fahoum, B. Harb","doi":"10.2174/1874347101307010009","DOIUrl":"https://doi.org/10.2174/1874347101307010009","url":null,"abstract":"In this paper, a combined Fractal and Wavelet (CFW) compression algorithm targeting x-ray angiogram images is proposed. Initially, the image is decomposed using wavelet transform. The smoothness of the low frequency part of the image appears as an approximation image with higher self similarities, therefore, it is coded using a fractal coding technique. However, the rest of the image is coded using an adaptive wavelet thresholding technique. This model is implemented and its performance is compared with best performances of the available published algorithms. A data set containing 1000 x-ray angiograms is used to study the performance of the algorithm. A minimum compression ratio of 30 with a peak signal to noise ratio (PSNR) of 36 dB and percent diameter stenosis deviation of (<0.2%) was achieved. Results demonstrate the effectiveness of the proposed technique in obtaining a diagnostic quality of reconstructed images at very low bit rates.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"97 1","pages":"9-18"},"PeriodicalIF":0.0,"publicationDate":"2013-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74697640","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
A Polynomial Fitting Improved Bayesian Reconstruction Method for Whole Brain Volumetric MRSI Metabolite Images 全脑磁共振成像代谢产物图像的多项式拟合改进贝叶斯重建方法
Pub Date : 2013-02-07 DOI: 10.2174/1874347101307010001
Yufang Bao, A. Maudsley
In this paper, a polynomial fitting improved Bayesian approach is proposed for the reconstruction of volumetric metabolite images from long echo time (TE) whole brain proton magnetic resonance spectroscopic imaging (MRSI) data. The proposed algorithm uses a modified EM (expectation maximization) algorithm that takes into account the partial vol- ume effects contained inside a thick slice MRSI. It incorporates high resolution volumetric magnetic resonance imaging (MRI) as a priori information. It further integrates the polynomial fitting method to smooth out artificial edges before the high resolution metabolite images are reconstructed. Our proposed reconstruction method has successfully extended our existing reconstruction of two dimensional (2D) metabolite images to 3D cases. The experimental results show that reso- lution enhanced volumetric metabolite images are reconstructed.
本文提出了一种多项式拟合改进的贝叶斯方法,用于长回波时间(TE)全脑质子磁共振光谱成像(MRSI)数据的体积代谢物图像重建。该算法采用了一种改进的EM(期望最大化)算法,该算法考虑了厚层磁共振成像中包含的部分体积效应。它结合了高分辨率体积磁共振成像(MRI)作为先验信息。在重建高分辨率代谢物图像之前,进一步结合多项式拟合方法对人工边缘进行平滑处理。我们提出的重建方法成功地将我们现有的二维(2D)代谢物图像重建扩展到3D病例。实验结果表明,重建了分辨率增强的体积代谢物图像。
{"title":"A Polynomial Fitting Improved Bayesian Reconstruction Method for Whole Brain Volumetric MRSI Metabolite Images","authors":"Yufang Bao, A. Maudsley","doi":"10.2174/1874347101307010001","DOIUrl":"https://doi.org/10.2174/1874347101307010001","url":null,"abstract":"In this paper, a polynomial fitting improved Bayesian approach is proposed for the reconstruction of volumetric metabolite images from long echo time (TE) whole brain proton magnetic resonance spectroscopic imaging (MRSI) data. The proposed algorithm uses a modified EM (expectation maximization) algorithm that takes into account the partial vol- ume effects contained inside a thick slice MRSI. It incorporates high resolution volumetric magnetic resonance imaging (MRI) as a priori information. It further integrates the polynomial fitting method to smooth out artificial edges before the high resolution metabolite images are reconstructed. Our proposed reconstruction method has successfully extended our existing reconstruction of two dimensional (2D) metabolite images to 3D cases. The experimental results show that reso- lution enhanced volumetric metabolite images are reconstructed.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"460 1","pages":"1-8"},"PeriodicalIF":0.0,"publicationDate":"2013-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82976905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cuda Parallel Implementation of Image Reconstruction Algorithm for Positron Emission Tomography Cuda并行实现正电子发射断层成像图像重建算法
Pub Date : 2012-12-14 DOI: 10.2174/1874347101206010108
Belzunce Ma, Verrastro Ca, E. Venialgo, Cohen Im
Although the use of iterative algorithms for image reconstruction in 3D Positron Emission Tomography (PET) has shown to produce images with better quality than analytical methods, they are computationally expensive. New Graphic Processor Units (GPUs) provide high performance at low cost and programming tools that make it possible to execute parallel algorithms in scientific applications. In this work, a GPU parallel implementation of the iterative reconstruction algorithm MLEM 3D has been developed using CUDA, a parallel model from NVIDIA. The Siddon algorithm was used as Projector and Backprojector. Acceleration factors up to 85 times were achieved, with respect to a single thread CPU implementation. The performance in GPU with Tesla and Fermi, which are respectively the first and the last generation of CUDA compatible architectures, has been compared. The image quality in each platform has been analyzed, showing a higher level of noise in GPU, due to race condition problems. The new features of Fermi architecture permitted to solve this problem using atomic operations.
虽然在三维正电子发射断层扫描(PET)中使用迭代算法进行图像重建已经显示出比分析方法产生更好质量的图像,但它们的计算成本很高。新的图形处理器单元(gpu)以低成本提供高性能和编程工具,使在科学应用中执行并行算法成为可能。在这项工作中,使用NVIDIA的并行模型CUDA开发了迭代重建算法MLEM 3D的GPU并行实现。投影和反向投影分别采用Siddon算法。相对于单线程CPU实现,实现了高达85倍的加速因子。比较了第一代和最后一代CUDA兼容架构Tesla和Fermi在GPU上的性能。对各平台的图像质量进行了分析,发现由于竞争条件问题,GPU的噪声水平较高。费米体系结构的新特性允许使用原子操作来解决这个问题。
{"title":"Cuda Parallel Implementation of Image Reconstruction Algorithm for Positron Emission Tomography","authors":"Belzunce Ma, Verrastro Ca, E. Venialgo, Cohen Im","doi":"10.2174/1874347101206010108","DOIUrl":"https://doi.org/10.2174/1874347101206010108","url":null,"abstract":"Although the use of iterative algorithms for image reconstruction in 3D Positron Emission Tomography (PET) has shown to produce images with better quality than analytical methods, they are computationally expensive. New Graphic Processor Units (GPUs) provide high performance at low cost and programming tools that make it possible to execute parallel algorithms in scientific applications. In this work, a GPU parallel implementation of the iterative reconstruction algorithm MLEM 3D has been developed using CUDA, a parallel model from NVIDIA. The Siddon algorithm was used as Projector and Backprojector. Acceleration factors up to 85 times were achieved, with respect to a single thread CPU implementation. The performance in GPU with Tesla and Fermi, which are respectively the first and the last generation of CUDA compatible architectures, has been compared. The image quality in each platform has been analyzed, showing a higher level of noise in GPU, due to race condition problems. The new features of Fermi architecture permitted to solve this problem using atomic operations.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"68 1","pages":"108-118"},"PeriodicalIF":0.0,"publicationDate":"2012-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76423685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Primary Central Nervous System Lymphoma with Lateral Ventricle Involvement 原发性中枢神经系统淋巴瘤伴侧脑室受累
Pub Date : 2012-10-05 DOI: 10.2174/1874347101206010103
Y. Oie, K. Murayama, S. Nagahisa, M. Abe, H. Toyama, K. Katada
A 77-year-old woman presented with worsening cognitive impairment, nausea and vomiting. Computed tomography (CT) of the head revealed a high-density mass that symmetrically filled both lateral ventricles. Magnetic resonance imaging (MRI) showed an enhanced mass with T1 and T2 prolongation and restricted diffusion on diffusion weighted imaging (DWI). Diagnosis was delayed until a post-mortem examination, which revealed the mass as a primary central nervous system lymphoma (PCNSL). A high-intensity tumor on DWI with lateral ventricle involvement should raise the possibility of PCNSL.
77岁女性,表现为认知障碍加重、恶心和呕吐。头部计算机断层扫描(CT)显示高密度肿块对称地填充两侧侧脑室。磁共振成像(MRI)示肿块增强,T1、T2延长,弥散加权成像(DWI)扩散受限。诊断被推迟到尸检,发现肿块为原发性中枢神经系统淋巴瘤(PCNSL)。DWI上高强度肿瘤累及侧脑室应提高PCNSL的可能性。
{"title":"Primary Central Nervous System Lymphoma with Lateral Ventricle Involvement","authors":"Y. Oie, K. Murayama, S. Nagahisa, M. Abe, H. Toyama, K. Katada","doi":"10.2174/1874347101206010103","DOIUrl":"https://doi.org/10.2174/1874347101206010103","url":null,"abstract":"A 77-year-old woman presented with worsening cognitive impairment, nausea and vomiting. Computed tomography (CT) of the head revealed a high-density mass that symmetrically filled both lateral ventricles. Magnetic resonance imaging (MRI) showed an enhanced mass with T1 and T2 prolongation and restricted diffusion on diffusion weighted imaging (DWI). Diagnosis was delayed until a post-mortem examination, which revealed the mass as a primary central nervous system lymphoma (PCNSL). A high-intensity tumor on DWI with lateral ventricle involvement should raise the possibility of PCNSL.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"232 1","pages":"103-107"},"PeriodicalIF":0.0,"publicationDate":"2012-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82751798","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Size Dependent Ultrasound Characteristics in Histologically Confirmed Papillary Thyroid Carcinomas: A Multivariate Analysis 组织学证实的甲状腺乳头状癌的大小依赖超声特征:多变量分析
Pub Date : 2012-08-08 DOI: 10.2174/1874347101206010097
M. Cordes, P. Kondrat, Karen Horstrup, T. Kuwert, M. Sasiadek
Background: Epidemiologic data revealed an increasing incidence of papillary carcinomas (PTCs) in the German population. There is some evidence that the size of resected PTCs has decreased during the last few years. Purpose: The aim of the present study was to test the hypothesis that the sonographic characteristics of PTCs vary with size. Material/Methods: Consecutive PTCs were histologically confirmed in 41 patients. Ultrasound examinations of these 50 PTCs were reevaluated retrospectively and classified according to five sonographic criteria. Results: It could be shown that the sonographic shape (p < 0.001), the contour (p = 0.024), the structure (p = 0.04), the echogenicity (p < 0.001) and calcifications (p = 0.008) varied with the size of the neoplasms. By factoranalysis a factor FPTC with an eigenvalue of 1.89 could be extracted from the data on which the sonographic structure, the ontour and the presence of calcifications had the strongest impact with factorloadings of 0.74, 0.68 and 0.61, respectively. Conclusion: The knowledge of the variation of the ultrasound characteristics should be of assistance for the sonographic classification of PTCs. In this context microcarcinomas usually do not display cystic components. However, they may show microcalcifications. Cystic components, hyperechogenicity and the taller-than-wide sign are predominantly seen in larger PTCs.
背景:流行病学数据显示,德国人群中乳头状癌(ptc)的发病率呈上升趋势。有一些证据表明,在过去几年中,切除的ptc的大小有所减少。目的:本研究的目的是验证ptc的超声特征随其大小而变化的假设。材料/方法:41例患者连续PTCs经组织学证实。对50例ptc的超声检查进行回顾性评估,并根据5项超声标准进行分类。结果:超声形态(p < 0.001)、轮廓(p = 0.024)、结构(p = 0.04)、回声强度(p < 0.001)和钙化程度(p = 0.008)随肿瘤大小的不同而不同。通过因子分析,可以提取出一个特征值为1.89的因子FPTC,其中超声结构、轮廓和钙化存在对其影响最大,因子负荷分别为0.74、0.68和0.61。结论:了解ptc的超声特征变化有助于ptc的超声分型。在这种情况下,微癌通常不显示囊性成分。然而,它们可能表现为微钙化。囊性成分、高回声和高宽征象主要见于较大的ptc。
{"title":"Size Dependent Ultrasound Characteristics in Histologically Confirmed Papillary Thyroid Carcinomas: A Multivariate Analysis","authors":"M. Cordes, P. Kondrat, Karen Horstrup, T. Kuwert, M. Sasiadek","doi":"10.2174/1874347101206010097","DOIUrl":"https://doi.org/10.2174/1874347101206010097","url":null,"abstract":"Background: Epidemiologic data revealed an increasing incidence of papillary carcinomas (PTCs) in the German population. There is some evidence that the size of resected PTCs has decreased during the last few years. Purpose: The aim of the present study was to test the hypothesis that the sonographic characteristics of PTCs vary with size. Material/Methods: Consecutive PTCs were histologically confirmed in 41 patients. Ultrasound examinations of these 50 PTCs were reevaluated retrospectively and classified according to five sonographic criteria. Results: It could be shown that the sonographic shape (p < 0.001), the contour (p = 0.024), the structure (p = 0.04), the echogenicity (p < 0.001) and calcifications (p = 0.008) varied with the size of the neoplasms. By factoranalysis a factor FPTC with an eigenvalue of 1.89 could be extracted from the data on which the sonographic structure, the ontour and the presence of calcifications had the strongest impact with factorloadings of 0.74, 0.68 and 0.61, respectively. Conclusion: The knowledge of the variation of the ultrasound characteristics should be of assistance for the sonographic classification of PTCs. In this context microcarcinomas usually do not display cystic components. However, they may show microcalcifications. Cystic components, hyperechogenicity and the taller-than-wide sign are predominantly seen in larger PTCs.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"39 1","pages":"97-102"},"PeriodicalIF":0.0,"publicationDate":"2012-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80515487","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Automated Voxel-Wise Brain DTI Analysis of Fitness and Aging 自动体素脑DTI分析健康和衰老
Pub Date : 2012-06-01 DOI: 10.2174/1874347101206010080
Zhexing Liu, Mahshid Farzinfar, L. Katz, Hongtu Zhu, C. Goodlett, G. Gerig, M. Styner, B. Marks
Diffusion Tensor Imaging (DTI) has become a widely used MR modality to investigate white matter integrity in the brain. This paper presents the application of an automated method for voxel-wise group comparisons of DTI images in a study of fitness and aging. The automated processing method consists of 3 steps: 1) preprocessing including image format converting, image quality control, eddy-current and motion artifact correction, skull stripping and tensor image estimation, 2) study-specific unbiased DTI atlas computation via diffeomorphic fluid-based and demons deformable registration and 3) voxel-wise statistical analysis via heterogeneous linear regression and a wild bootstrap technique for correcting for multiple comparisons. Our results show that this fully automated method is suitable for voxel-wise group DTI analysis. Furthermore, in older adults, the results suggest a strong link between reduced fractional anisotropy (FA) values, fitness and aging.
弥散张量成像(DTI)已成为一种广泛应用于脑白质完整性研究的MR方式。本文介绍了在健康和衰老研究中,DTI图像体素组比较的自动化方法的应用。自动化处理方法包括3个步骤:1)预处理,包括图像格式转换、图像质量控制、涡流和运动伪影校正、头骨去除和张量图像估计;2)通过基于微分同构流体和可变形配准的研究特定的无偏DTI图谱计算;3)通过异构线性回归和野自举技术进行体素统计分析,用于校正多个比较。我们的结果表明,这种全自动方法适用于体素级群DTI分析。此外,在老年人中,结果表明分数各向异性(FA)值降低与健康和衰老之间存在密切联系。
{"title":"Automated Voxel-Wise Brain DTI Analysis of Fitness and Aging","authors":"Zhexing Liu, Mahshid Farzinfar, L. Katz, Hongtu Zhu, C. Goodlett, G. Gerig, M. Styner, B. Marks","doi":"10.2174/1874347101206010080","DOIUrl":"https://doi.org/10.2174/1874347101206010080","url":null,"abstract":"Diffusion Tensor Imaging (DTI) has become a widely used MR modality to investigate white matter integrity in the brain. This paper presents the application of an automated method for voxel-wise group comparisons of DTI images in a study of fitness and aging. The automated processing method consists of 3 steps: 1) preprocessing including image format converting, image quality control, eddy-current and motion artifact correction, skull stripping and tensor image estimation, 2) study-specific unbiased DTI atlas computation via diffeomorphic fluid-based and demons deformable registration and 3) voxel-wise statistical analysis via heterogeneous linear regression and a wild bootstrap technique for correcting for multiple comparisons. Our results show that this fully automated method is suitable for voxel-wise group DTI analysis. Furthermore, in older adults, the results suggest a strong link between reduced fractional anisotropy (FA) values, fitness and aging.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"70 ","pages":"80-88"},"PeriodicalIF":0.0,"publicationDate":"2012-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72549394","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Sentinel node navigation surgery with 99mTc-tin colloid in breast cancer: Radiation safety considerations 99mtc -锡胶体在乳腺癌前哨淋巴结导航手术中的放射安全性考虑
Pub Date : 2012-06-01 DOI: 10.2174/1874347101206010089
K. Ejiri, K. Minami, H. Toyama, Gen Kudo, Hidekazu Hattori, N. Kobayashi, Masaki Kato, Masanobu Ishiguro, H. Fujii, M. Kuroda, T. Utsumi, K. Iwase, K. Katada
Purpose: The incident at the Fukushima Daiichi nuclear power station in 2011 has again raised concerns with the public regarding radiation exposure, especially so in medical workers and patients undergoing treatment involving the use of radiation. Radioisotopes are currently used during sentinel node navigation surgery (SNNS) in operating rooms without radiation monitoring. To re-evaluate the safety issues, the potential effective dose (Epoten) from 99m Tc-tin (-Sn) colloid in breast cancer surgery was estimated and personal dose equivalents, Hp(10) and Hp(0.07), were measured during SNNS. Materials and methods: Seventeen breast cancer patients were enrolled. One day before SNNS, 99m Tc-Sn colloid was injected around the tumor and radiation exposure rates were measured using survey meters. Personal dose equivalents for the surgical workers were measured. Hp(10) and Hp(0.07) for the body and Hp(0.07) for the hands were recorded using semiconductor detectors and ring-type glass dosimeters. Results: The maximum Epoten was 29 μSv per 74 MBq injection. The maximum Hp(10) for the primary and assisting surgeons, nurse, and anesthetist was 3.7, 1.4, 0.3 and 0.6 μSv per SNNS, respectively. The maximum Hp(0.07) for the hands was 100 μSv. Maximum radiocontamination 20 times higher than background (0.05 μSv/h) was detected in bloody gauze. Conclusion: The workers' radiation dose exposure from SNNS was not high, although radiation management such as a temporary cooling off period may be required.
目的:2011年福岛第一核电站事件再次引起公众对辐射暴露的关注,特别是对医务工作者和接受涉及使用辐射治疗的患者的关注。放射性同位素目前在没有辐射监测的手术室中用于前哨淋巴结导航手术(SNNS)。为了重新评估安全性问题,我们估计了99m Tc-tin (-Sn)胶体在乳腺癌手术中的潜在有效剂量(Epoten),并测量了SNNS期间的个人剂量当量Hp(10)和Hp(0.07)。材料与方法:纳入17例乳腺癌患者。SNNS前1天,在肿瘤周围注射99m Tc-Sn胶体,用测量表测量辐射暴露率。测量了手术工人的个人剂量当量。用半导体探测器和环形玻璃剂量计分别记录了人体Hp(10)和手部Hp(0.07)。结果:epten最高为29 μSv / 74 MBq;主治和辅助外科医生、护士和麻醉师的最大Hp(10)分别为3.7、1.4、0.3和0.6 μSv / SNNS。手的最大Hp(0.07)为100 μSv。血纱布的最大放射性污染值为本底的20倍(0.05 μSv/h)。结论:工人受到SNNS的辐射剂量不高,但可能需要进行临时冷却期等辐射管理。
{"title":"Sentinel node navigation surgery with 99mTc-tin colloid in breast cancer: Radiation safety considerations","authors":"K. Ejiri, K. Minami, H. Toyama, Gen Kudo, Hidekazu Hattori, N. Kobayashi, Masaki Kato, Masanobu Ishiguro, H. Fujii, M. Kuroda, T. Utsumi, K. Iwase, K. Katada","doi":"10.2174/1874347101206010089","DOIUrl":"https://doi.org/10.2174/1874347101206010089","url":null,"abstract":"Purpose: The incident at the Fukushima Daiichi nuclear power station in 2011 has again raised concerns with the public regarding radiation exposure, especially so in medical workers and patients undergoing treatment involving the use of radiation. Radioisotopes are currently used during sentinel node navigation surgery (SNNS) in operating rooms without radiation monitoring. To re-evaluate the safety issues, the potential effective dose (Epoten) from 99m Tc-tin (-Sn) colloid in breast cancer surgery was estimated and personal dose equivalents, Hp(10) and Hp(0.07), were measured during SNNS. Materials and methods: Seventeen breast cancer patients were enrolled. One day before SNNS, 99m Tc-Sn colloid was injected around the tumor and radiation exposure rates were measured using survey meters. Personal dose equivalents for the surgical workers were measured. Hp(10) and Hp(0.07) for the body and Hp(0.07) for the hands were recorded using semiconductor detectors and ring-type glass dosimeters. Results: The maximum Epoten was 29 μSv per 74 MBq injection. The maximum Hp(10) for the primary and assisting surgeons, nurse, and anesthetist was 3.7, 1.4, 0.3 and 0.6 μSv per SNNS, respectively. The maximum Hp(0.07) for the hands was 100 μSv. Maximum radiocontamination 20 times higher than background (0.05 μSv/h) was detected in bloody gauze. Conclusion: The workers' radiation dose exposure from SNNS was not high, although radiation management such as a temporary cooling off period may be required.","PeriodicalId":90366,"journal":{"name":"The open medical imaging journal","volume":"6 1","pages":"89-96"},"PeriodicalIF":0.0,"publicationDate":"2012-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81239454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
期刊
The open medical imaging journal
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1