2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)最新文献

英文 中文
Three-port impedance model and validation of VSCs for stability analysis 三端口阻抗模型及VSCs稳定性分析验证
H. Zong, C. Zhang, X. Cai, M. Molinas
Modern power system is undergoing a paradigm shift from the synchronous generators-based system to the power electronics converters-dominated system. With the high penetration of converters, serious stability problems are provoked, especially the wideband oscillations (e.g., sub-synchronous oscillations, harmonic oscillations, etc). Various studies have been conducted in this respect, while most of them separate the ac-side stability with the dc-side stability. However, for the stability analysis of the hybrid AC/DC grid, it is necessary to consider the converter's ac-side and dc-side, simultaneously. In this paper, the stability analysis of voltage source converters (VSCs) considering both ac and dc dynamics is carried out. At first, the threeport AC/DC admittance model of VSCs is established, and the corresponding measurement method from simulations is presented to validate its accuracy. Secondly, based on such three-port model, two stability analysis methods are presented: the one is based on the system open-loop model, where the stability can be judged via the Generalized Nyquist Criterion (GNC); the other one is based on the system closed-loop model, whose stability can be predicted through the pole-zero calculation. At last, a test AC/DC system is built in MATLAB/Simulink, by which the effectiveness of the three-port model-based stability analysis is validated.
现代电力系统正经历着由以同步发电机为主的系统向以电力电子变流器为主的系统的范式转变。随着变换器的高穿深,引起了严重的稳定性问题,特别是宽带振荡(如次同步振荡、谐波振荡等)。在这方面进行了各种研究,但大多数研究将交流侧稳定性与直流侧稳定性分开。然而,对于交直流混合电网的稳定性分析,需要同时考虑变流器的交流侧和直流侧。本文对电压源变换器(VSCs)进行了考虑交流和直流动态的稳定性分析。首先,建立了VSCs的三口交/直流导纳模型,并通过仿真给出了相应的测量方法,验证了模型的准确性。其次,在此三端口模型的基础上,提出了两种稳定性分析方法:一种是基于系统开环模型,通过广义奈奎斯特准则(GNC)判断系统的稳定性;另一种是基于系统闭环模型,通过极点-零点计算来预测系统的稳定性。最后,在MATLAB/Simulink中搭建了一个交直流测试系统,验证了基于三端口模型的稳定性分析方法的有效性。
{"title":"Three-port impedance model and validation of VSCs for stability analysis","authors":"H. Zong, C. Zhang, X. Cai, M. Molinas","doi":"10.1049/icp.2021.2578","DOIUrl":"https://doi.org/10.1049/icp.2021.2578","url":null,"abstract":"Modern power system is undergoing a paradigm shift from the synchronous generators-based system to the power electronics converters-dominated system. With the high penetration of converters, serious stability problems are provoked, especially the wideband oscillations (e.g., sub-synchronous oscillations, harmonic oscillations, etc). Various studies have been conducted in this respect, while most of them separate the ac-side stability with the dc-side stability. However, for the stability analysis of the hybrid AC/DC grid, it is necessary to consider the converter's ac-side and dc-side, simultaneously. In this paper, the stability analysis of voltage source converters (VSCs) considering both ac and dc dynamics is carried out. At first, the threeport AC/DC admittance model of VSCs is established, and the corresponding measurement method from simulations is presented to validate its accuracy. Secondly, based on such three-port model, two stability analysis methods are presented: the one is based on the system open-loop model, where the stability can be judged via the Generalized Nyquist Criterion (GNC); the other one is based on the system closed-loop model, whose stability can be predicted through the pole-zero calculation. At last, a test AC/DC system is built in MATLAB/Simulink, by which the effectiveness of the three-port model-based stability analysis is validated.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126312605","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Transient synchronization stability analysis of wind farms with MMC-HVDC integration under offshore AC grid fault 海上交流电网故障下MMC-HVDC一体化风电场暂态同步稳定性分析
Yu Zhang, Chen Zhang, Renxin Yang, J. Lyu, Li Liu, X. Cai
The MMC-HVDC connected offshore wind farms (OWFs) could suffer short circuit fault (SCF), whereas their transient stability is not well analysed. In this paper, the mechanism of the loss of synchronization (LOS) of this system is analysed considering the whole system state from the fault-on to the post-fault, and the discussion on fault type and fault clearance is addressed as well. A stability index is proposed to quantify the transient synchronization stability (TSS) of the system, which is capable to not only estimate whether the wind turbine generators (WTGs) be able to get resynchronized with the offshore MMC after the fault is cleared, but also to evaluate the performance of stability improving methods as well. Finally, a scenario of six cases is tested on the PSCAD/EMTDC simulation platform, where the performances of four existing stability improving methods are thoroughly compared via both numerical simulation and the proposed stability index.
MMC-HVDC连接的海上风电场(owf)可能出现短路故障(SCF),而其暂态稳定性分析尚不充分。本文从系统从启动到故障后的整个状态出发,分析了该系统同步丢失的机理,并对故障类型和故障清除进行了讨论。提出了一种量化系统暂态同步稳定性的稳定指标,该指标不仅能够估计故障清除后风力发电机组是否能够与海上MMC重新同步,而且还可以评估稳定性改进方法的性能。最后,在PSCAD/EMTDC仿真平台上对六种情况进行了测试,通过数值模拟和提出的稳定性指标,对现有四种稳定性改进方法的性能进行了全面比较。
{"title":"Transient synchronization stability analysis of wind farms with MMC-HVDC integration under offshore AC grid fault","authors":"Yu Zhang, Chen Zhang, Renxin Yang, J. Lyu, Li Liu, X. Cai","doi":"10.1049/icp.2021.2585","DOIUrl":"https://doi.org/10.1049/icp.2021.2585","url":null,"abstract":"The MMC-HVDC connected offshore wind farms (OWFs) could suffer short circuit fault (SCF), whereas their transient stability is not well analysed. In this paper, the mechanism of the loss of synchronization (LOS) of this system is analysed considering the whole system state from the fault-on to the post-fault, and the discussion on fault type and fault clearance is addressed as well. A stability index is proposed to quantify the transient synchronization stability (TSS) of the system, which is capable to not only estimate whether the wind turbine generators (WTGs) be able to get resynchronized with the offshore MMC after the fault is cleared, but also to evaluate the performance of stability improving methods as well. Finally, a scenario of six cases is tested on the PSCAD/EMTDC simulation platform, where the performances of four existing stability improving methods are thoroughly compared via both numerical simulation and the proposed stability index.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130361048","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Research on MMC de-icing system capable of power grid interconnection 电网互联MMC除冰系统研究
X. Yan, Z. Yuebin, B. Guobang, C. Wanyu, Y. Liuqing, Y. Wenyong, L. Qiansu, Z. Ronghua, X. Shukai, F. Chuang
Voltage sourced converter (VSC) de-icing device has been gradually applied because of its advantages, such as no requirements on by-pass transformer, no harmonic output on AC side, and small floor area. However, the DC de-icing device will only operate in winter, resulting in low utilization rate. In order to improve the utilization rate of equipment and the power supply reliability of the distribution network, this paper analyzes the current situation of DC de-icing technology and proposes a VSC-HVDC de-icing system composed of two sets of voltage-source DC de-icing devices, which can improve the de-icing efficiency in parallel; Some strategies are proposed, such as AC power balance control of sectionalized busbar under VSC interconnection of de-icing devices as well as emergency power transfer for AC single-end power loss. The paper also builds an EMTDC simulation model of the VSC DC de-icing system and carries out a simulation test, which verifies the functions of the VSC-HVDC de-icing system, such as ice-melting, VAR compensation, AC power balance, and emergency power transfer for AC single-end power loss, etc. The related functions are also verified in the engineering site, which shows that the VSC-HVDC de-icing system proposed in this paper can improve the power supply reliability of distribution substations.
电压源变换器除冰装置因其不需要旁路变压器、交流侧无谐波输出、占地面积小等优点而逐渐得到应用。但直流除冰装置只在冬季运行,利用率较低。为了提高设备的利用率和配电网供电的可靠性,分析了直流除冰技术的现状,提出了一种由两组电压源直流除冰装置组成的vdc - hvdc除冰系统,可提高并联除冰效率;提出了除冰装置VSC互联下分段母线交流功率平衡控制、交流单端失电应急送电等策略。本文还建立了VSC直流除冰系统的EMTDC仿真模型,并进行了仿真试验,验证了VSC- hvdc除冰系统的融冰、无功补偿、交流功率平衡、交流单端失电应急送电等功能。相关功能也在工程现场得到验证,表明本文提出的VSC-HVDC除冰系统可以提高配电变电站的供电可靠性。
{"title":"Research on MMC de-icing system capable of power grid interconnection","authors":"X. Yan, Z. Yuebin, B. Guobang, C. Wanyu, Y. Liuqing, Y. Wenyong, L. Qiansu, Z. Ronghua, X. Shukai, F. Chuang","doi":"10.1049/icp.2021.2534","DOIUrl":"https://doi.org/10.1049/icp.2021.2534","url":null,"abstract":"Voltage sourced converter (VSC) de-icing device has been gradually applied because of its advantages, such as no requirements on by-pass transformer, no harmonic output on AC side, and small floor area. However, the DC de-icing device will only operate in winter, resulting in low utilization rate. In order to improve the utilization rate of equipment and the power supply reliability of the distribution network, this paper analyzes the current situation of DC de-icing technology and proposes a VSC-HVDC de-icing system composed of two sets of voltage-source DC de-icing devices, which can improve the de-icing efficiency in parallel; Some strategies are proposed, such as AC power balance control of sectionalized busbar under VSC interconnection of de-icing devices as well as emergency power transfer for AC single-end power loss. The paper also builds an EMTDC simulation model of the VSC DC de-icing system and carries out a simulation test, which verifies the functions of the VSC-HVDC de-icing system, such as ice-melting, VAR compensation, AC power balance, and emergency power transfer for AC single-end power loss, etc. The related functions are also verified in the engineering site, which shows that the VSC-HVDC de-icing system proposed in this paper can improve the power supply reliability of distribution substations.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"175 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124294444","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Summary of research on cascading failures of high proportion new energy power systems 高比例新能源电力系统级联故障研究综述
A. Wang, W. Zhong, Z. Shen, X. Wang, Y. Yang
In recent years, the research on cascading failures of high proportion new energy power systems has gradually attracted attention. Combine the definition and classification of cascading failures, the characteristics of power system cascading failures after the connection of new energy generation is analyzed. And, from the perspective of the uncertainty analysis after the connection of new energy generation and the cascading trip-off of new energy generators, the status of the research on the mechanism of cascading failures in new energy systems is collected. Wide area control measures at different time scales in systems are integrated. The comprehensive defense method of cascading failures is divided into three parts: component strengthening, operating state optimization and cascading failure blocking control. The key technical issues in the study of cascading failures in new energy grid-connected systems are discussed.
近年来,高比例新能源电力系统级联故障的研究逐渐受到重视。结合级联故障的定义和分类,分析了新能源发电并网后电力系统级联故障的特点。并从新能源发电并网和新能源发电机级联脱扣后的不确定性分析角度,收集了新能源系统级联失效机理的研究现状。对系统中不同时间尺度的广域控制措施进行了集成。级联故障综合防御方法分为组件强化、运行状态优化和级联故障阻断控制三个部分。讨论了新能源并网系统级联故障研究中的关键技术问题。
{"title":"Summary of research on cascading failures of high proportion new energy power systems","authors":"A. Wang, W. Zhong, Z. Shen, X. Wang, Y. Yang","doi":"10.1049/icp.2021.2586","DOIUrl":"https://doi.org/10.1049/icp.2021.2586","url":null,"abstract":"In recent years, the research on cascading failures of high proportion new energy power systems has gradually attracted attention. Combine the definition and classification of cascading failures, the characteristics of power system cascading failures after the connection of new energy generation is analyzed. And, from the perspective of the uncertainty analysis after the connection of new energy generation and the cascading trip-off of new energy generators, the status of the research on the mechanism of cascading failures in new energy systems is collected. Wide area control measures at different time scales in systems are integrated. The comprehensive defense method of cascading failures is divided into three parts: component strengthening, operating state optimization and cascading failure blocking control. The key technical issues in the study of cascading failures in new energy grid-connected systems are discussed.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127939319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis and suppression of subsynchronous oscillation of Rudong wind power through MMC-HVDC system MMC-HVDC系统对如东风电次同步振荡的分析与抑制
J. Li, X. Xie, J. Yang, H. Li, Z. Shi, K. Wang, C. Fu, W. Yang
There may be complex interaction between the converter control systems of wind power and MMC-HVDC, which will lead to sub-/super-synchronous oscillation and threaten the safe and stable operation of the system. The relevant events have been reported in Guangdong Nan'ao, Shanghai Nanhui and Zhangbei projects. Rudong offshore wind power project is the first offshore wind power transmission system in China, and it is still under construction. Therefore, it is of great significance to carry out the research on the risk analysis and suppression measures of sub-synchronous oscillation in Rudong wind power MMC-HVDC system. First, the time-domain simulation model of Rudong wind power MMC-HVDC system is built in the PSCAD/EMTDC simulation model. Then, the effects of the number of wind turbine generators, wind power output and the parameters of MMC-HVDC controller on the sub-/super-synchronous oscillation characteristics of the system are further analyzed. Finally, the suppression measures based on supplementary frequency dependent gain control are proposed, the application position of the controller is discussed, and the parameter optimization method of the controller is given. The research content provides a certain guiding significance for the operation and control of Rudong wind power MMC-HVDC.
风电变流器控制系统与MMC-HVDC之间可能存在复杂的相互作用,导致亚/超同步振荡,威胁系统的安全稳定运行。广东南澳、上海南汇、张北等项目均有相关报道。如东海上风电项目是中国首个海上风电传输系统,目前仍在建设中。因此,开展如东风电MMC-HVDC系统次同步振荡风险分析及抑制措施研究具有重要意义。首先,在PSCAD/EMTDC仿真模型中建立如东风电MMC-HVDC系统的时域仿真模型。然后,进一步分析了风力发电机组数量、风力输出功率以及MMC-HVDC控制器参数对系统亚/超同步振荡特性的影响。最后,提出了基于补充频率相关增益控制的抑制措施,讨论了控制器的应用位置,并给出了控制器的参数优化方法。研究内容对如东风电MMC-HVDC的运行控制具有一定的指导意义。
{"title":"Analysis and suppression of subsynchronous oscillation of Rudong wind power through MMC-HVDC system","authors":"J. Li, X. Xie, J. Yang, H. Li, Z. Shi, K. Wang, C. Fu, W. Yang","doi":"10.1049/icp.2021.2553","DOIUrl":"https://doi.org/10.1049/icp.2021.2553","url":null,"abstract":"There may be complex interaction between the converter control systems of wind power and MMC-HVDC, which will lead to sub-/super-synchronous oscillation and threaten the safe and stable operation of the system. The relevant events have been reported in Guangdong Nan'ao, Shanghai Nanhui and Zhangbei projects. Rudong offshore wind power project is the first offshore wind power transmission system in China, and it is still under construction. Therefore, it is of great significance to carry out the research on the risk analysis and suppression measures of sub-synchronous oscillation in Rudong wind power MMC-HVDC system. First, the time-domain simulation model of Rudong wind power MMC-HVDC system is built in the PSCAD/EMTDC simulation model. Then, the effects of the number of wind turbine generators, wind power output and the parameters of MMC-HVDC controller on the sub-/super-synchronous oscillation characteristics of the system are further analyzed. Finally, the suppression measures based on supplementary frequency dependent gain control are proposed, the application position of the controller is discussed, and the parameter optimization method of the controller is given. The research content provides a certain guiding significance for the operation and control of Rudong wind power MMC-HVDC.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127979238","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Research on electrical contact fault characteristics of GIS circuit breaker based on vibration signal 基于振动信号的GIS断路器电触点故障特征研究
C. Baiquan, C. Bangfa, W. Pengyang, G. Xuan, L. Qiang
In order to analyze the vibration characteristics of GIS equipment when the contact is poor, we established a threedimensional model of 40.5kV circuit breaker by using the magnetism and solid coupling method. By changing the ratio of the close contact area of moving and stationary contacts to the total area of moving contacts (contact ratio), the situation of poor electrical contact was simulated and analyzed. The simulation results show that, when the contact ratio is constant, the current increases from 1000A to 3000A, and the acceleration of the contact also increases. In the case of the same current, the acceleration value when the contact ratio is 0.3 is greater than the value when the contact ratio is 0.6. When the contact ratio is 0.3 and the current is 3000A, the acceleration amplitude of the component with the frequency of 100Hz is the largest, which is 0.07m/s2. After research and analysis, it is shown that the vibration signal is based on 100Hz as the fundamental frequency. At the same time, multiple frequency components such as 300Hz, 600Hz and some other high-frequency components are generated. Therefore, the contact state can be judged through the measurement and analysis of the vibration signal.
为了分析GIS设备在接触不良时的振动特性,采用磁固耦合法建立了40.5kV断路器的三维模型。通过改变动触点与静止触点的紧密接触面积占动触点总面积的比例(接触比),对电接触不良的情况进行了仿真分析。仿真结果表明,当接触比一定时,电流从1000A增大到3000A,接触加速度也随之增大。在电流相同的情况下,接触比为0.3时的加速度值大于接触比为0.6时的加速度值。当接触比为0.3,电流为3000A时,频率为100Hz的元件加速度幅值最大,为0.07m/s2。研究分析表明,振动信号以100Hz为基频。同时产生300Hz、600Hz等多个频率分量以及其他一些高频分量。因此,可以通过对振动信号的测量和分析来判断接触状态。
{"title":"Research on electrical contact fault characteristics of GIS circuit breaker based on vibration signal","authors":"C. Baiquan, C. Bangfa, W. Pengyang, G. Xuan, L. Qiang","doi":"10.1049/icp.2021.2546","DOIUrl":"https://doi.org/10.1049/icp.2021.2546","url":null,"abstract":"In order to analyze the vibration characteristics of GIS equipment when the contact is poor, we established a threedimensional model of 40.5kV circuit breaker by using the magnetism and solid coupling method. By changing the ratio of the close contact area of moving and stationary contacts to the total area of moving contacts (contact ratio), the situation of poor electrical contact was simulated and analyzed. The simulation results show that, when the contact ratio is constant, the current increases from 1000A to 3000A, and the acceleration of the contact also increases. In the case of the same current, the acceleration value when the contact ratio is 0.3 is greater than the value when the contact ratio is 0.6. When the contact ratio is 0.3 and the current is 3000A, the acceleration amplitude of the component with the frequency of 100Hz is the largest, which is 0.07m/s2. After research and analysis, it is shown that the vibration signal is based on 100Hz as the fundamental frequency. At the same time, multiple frequency components such as 300Hz, 600Hz and some other high-frequency components are generated. Therefore, the contact state can be judged through the measurement and analysis of the vibration signal.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125074110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis and simulation of UPFC device on power flow optimization and suppression of short-circuit faults of network transmission line UPFC装置对网络传输线潮流优化和短路故障抑制的分析与仿真
G. Gao, K. Zhu
With the gradual expansion of the scale of new energy grid connection and the improvement of the level of residential power consumption, the regional grid load has shown an intensive and rapid growth, which results in an increase in the electrical distance of the transmission line. And the line is likely to cause phenomena such as power flow exceeding or under working conditions. Therefore, it is necessary to install power electronic devices to realize functions such as power flow regulation and reactive power compensation, and to improve the transmission efficiency of the grid. This article first introduces the working principle of the UPFC device and then analyses the current common engineering application examples of the UPFC. Finally, a simulation model of the loop network is carried out, and conducts the power flow calculation and short circuit experiment, The results show that the UPFC device has obvious effects on improving the line power flow and suppressing fault of short circuits.
随着新能源并网规模的逐步扩大和居民用电水平的提高,区域电网负荷呈现密集快速增长,导致输电线路电气距离增加。而线路很可能造成功率流超过或低于工作状态等现象。因此,有必要安装电力电子装置,实现潮流调节和无功补偿等功能,提高电网的输电效率。本文首先介绍了UPFC器件的工作原理,然后分析了目前UPFC常见的工程应用实例。最后,建立了环路网络仿真模型,并进行了潮流计算和短路实验,结果表明,UPFC装置在改善线路潮流和抑制短路故障方面具有明显的效果。
{"title":"Analysis and simulation of UPFC device on power flow optimization and suppression of short-circuit faults of network transmission line","authors":"G. Gao, K. Zhu","doi":"10.1049/icp.2021.2582","DOIUrl":"https://doi.org/10.1049/icp.2021.2582","url":null,"abstract":"With the gradual expansion of the scale of new energy grid connection and the improvement of the level of residential power consumption, the regional grid load has shown an intensive and rapid growth, which results in an increase in the electrical distance of the transmission line. And the line is likely to cause phenomena such as power flow exceeding or under working conditions. Therefore, it is necessary to install power electronic devices to realize functions such as power flow regulation and reactive power compensation, and to improve the transmission efficiency of the grid. This article first introduces the working principle of the UPFC device and then analyses the current common engineering application examples of the UPFC. Finally, a simulation model of the loop network is carried out, and conducts the power flow calculation and short circuit experiment, The results show that the UPFC device has obvious effects on improving the line power flow and suppressing fault of short circuits.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129762796","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fault identification method of MMC-HVDC based on GRU neural network 基于GRU神经网络的MMC-HVDC故障识别方法
D. Zheng, Y. Wang, W. Mo
In order to transport renewable energy cross regions, building a Modular Multilevel Converter-based High Voltage Direct Current (MMCHVDC) system has become one of the important means. It is necessary to build a high precision and fast response fault identification method to ensure the stability of the system. This research proposes a new fault identification technology based on Gated Recurrent Unit (GRU). This method uses single-ended sensors to obtain the current and voltage before and after the fault. Through the trained neural network based on GRU, it can accurately identify the fault type of the MMC-HVDC system. The simulation experiments indicated that the fault diagnosis method of MMC-HVDC system based on GRU can meet the fault identification speed requirement (3 ms), and the accuracy can reach at 98.94%.
为了实现可再生能源的跨区域传输,构建基于模块化多电平变换器的高压直流(MMCHVDC)系统已成为重要手段之一。为了保证系统的稳定性,有必要建立一种高精度、快速响应的故障识别方法。提出了一种基于门控循环单元(GRU)的故障识别技术。该方法采用单端传感器获取故障前后的电流和电压。通过基于GRU的训练神经网络,可以准确识别MMC-HVDC系统的故障类型。仿真实验表明,基于GRU的MMC-HVDC系统故障诊断方法能够满足故障识别速度(3 ms)的要求,准确率达到98.94%。
{"title":"Fault identification method of MMC-HVDC based on GRU neural network","authors":"D. Zheng, Y. Wang, W. Mo","doi":"10.1049/icp.2021.2580","DOIUrl":"https://doi.org/10.1049/icp.2021.2580","url":null,"abstract":"In order to transport renewable energy cross regions, building a Modular Multilevel Converter-based High Voltage Direct Current (MMCHVDC) system has become one of the important means. It is necessary to build a high precision and fast response fault identification method to ensure the stability of the system. This research proposes a new fault identification technology based on Gated Recurrent Unit (GRU). This method uses single-ended sensors to obtain the current and voltage before and after the fault. Through the trained neural network based on GRU, it can accurately identify the fault type of the MMC-HVDC system. The simulation experiments indicated that the fault diagnosis method of MMC-HVDC system based on GRU can meet the fault identification speed requirement (3 ms), and the accuracy can reach at 98.94%.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128507884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A fault testing method of hvdc converter valve control unit based on TCU structure 基于TCU结构的直流换流阀控制单元故障检测方法
H. Cong, W. Rongchao, S. Yang
As the basic control unit of thyristor, the reliability of thyristor control unit (TCU) is a fatal device for the reliability of HVDC transmission system. However, the defects of TCU frequently occurred in ±500kV Gui Zhong converter station, such as IP loss, IP oscillation, protective triggering and other abnormal phenomena. Meanwhile, standard of test method and system specially designed for TCU neither existed in Chinese discipline nor in IEC-60700-1. So it is necessary to design special tests on TCU which aim to recover the fault and find out the causes before being put into use. The paper presented the TCU test method, which is used to analyze the fault part of TCU in the converter station. The defeated components are successfully proved to be clipped triode inside the TCU. The test method is necessary supplement for test standard, operation and overhaul of HVDC transmission projects.
晶闸管控制单元(TCU)作为晶闸管的基本控制单元,其可靠性是影响直流输电系统可靠性的关键器件。然而,在±500kV贵中换流站中,TCU的缺陷经常发生,如IP丢失、IP振荡、保护触发等异常现象。同时,在中国学科和IEC-60700-1中都没有专门为TCU设计的测试方法和系统的标准。因此,有必要在TCU投入使用前设计专门的故障恢复试验,找出故障原因。介绍了换流站TCU故障部分的测试方法,并对故障部分进行了分析。失败的组件被成功地证明是夹波三极管内部的TCU。该试验方法是对高压直流输电工程试验标准、运行和检修的必要补充。
{"title":"A fault testing method of hvdc converter valve control unit based on TCU structure","authors":"H. Cong, W. Rongchao, S. Yang","doi":"10.1049/icp.2021.2532","DOIUrl":"https://doi.org/10.1049/icp.2021.2532","url":null,"abstract":"As the basic control unit of thyristor, the reliability of thyristor control unit (TCU) is a fatal device for the reliability of HVDC transmission system. However, the defects of TCU frequently occurred in ±500kV Gui Zhong converter station, such as IP loss, IP oscillation, protective triggering and other abnormal phenomena. Meanwhile, standard of test method and system specially designed for TCU neither existed in Chinese discipline nor in IEC-60700-1. So it is necessary to design special tests on TCU which aim to recover the fault and find out the causes before being put into use. The paper presented the TCU test method, which is used to analyze the fault part of TCU in the converter station. The defeated components are successfully proved to be clipped triode inside the TCU. The test method is necessary supplement for test standard, operation and overhaul of HVDC transmission projects.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132022283","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fault current suppression for MMC-MTDC with the resistive type superconducting fault current limiter 电阻式超导故障限流器对MMC-MTDC故障电流的抑制
G. Liu, Ping Guo, Zheng Yuan, Y. Zhao
With effective properties, a resistive-type superconducting fault current limit (R-SFCL) has become an effective device to restrain DC-side bipolar short fault currents in multilevel modular converter multiterminal DC systems (MMC-MTDCs). However, due to the resistance-energy accumulation-dependent characteristics of the R-SFCL device, the fault durations and different fault current values will produce various output resistances at each fault stage, and the related coordinated protection and control strategy needs to be adjusted accordingly. Therefore, in the first part of this paper, we analysed the DC side short circuit current mechanism and the fault current restraint characteristics of R-SFCLs. Subsequently, to verify the above analysis, the R-SFCL-based four-terminal MMC-MTDC with DC bipolar short fault modelling and simulation are presented in the next section. Finally, based on the above analysis and research, the advanced DC bipolar fault control and protection strategies of the R-SFCL-based MMC-MTDC system are discussed to promote further study of coordinated and protection control and the application of R-SFCLs in subsequent engineering applications.
电阻型超导故障限流器(R-SFCL)具有良好的性能,已成为抑制多电平模块化变换器多终端直流系统(mmc - mtdc)直流侧双极短故障电流的有效器件。然而,由于R-SFCL器件的电阻-能量累积特性,故障持续时间和不同的故障电流值会在每个故障阶段产生不同的输出电阻值,需要相应地调整相应的协调保护和控制策略。因此,在本文的第一部分,我们分析了R-SFCLs直流侧短路电流机理和故障电流抑制特性。随后,为了验证上述分析,在下一节中提出了基于r- sfcl的直流双极短故障四端MMC-MTDC建模和仿真。最后,在上述分析和研究的基础上,讨论了基于r - sfcl的MMC-MTDC系统的先进直流双极故障控制和保护策略,以促进r - sfcl在后续工程应用中的协调和保护控制的进一步研究和应用。
{"title":"Fault current suppression for MMC-MTDC with the resistive type superconducting fault current limiter","authors":"G. Liu, Ping Guo, Zheng Yuan, Y. Zhao","doi":"10.1049/icp.2021.2530","DOIUrl":"https://doi.org/10.1049/icp.2021.2530","url":null,"abstract":"With effective properties, a resistive-type superconducting fault current limit (R-SFCL) has become an effective device to restrain DC-side bipolar short fault currents in multilevel modular converter multiterminal DC systems (MMC-MTDCs). However, due to the resistance-energy accumulation-dependent characteristics of the R-SFCL device, the fault durations and different fault current values will produce various output resistances at each fault stage, and the related coordinated protection and control strategy needs to be adjusted accordingly. Therefore, in the first part of this paper, we analysed the DC side short circuit current mechanism and the fault current restraint characteristics of R-SFCLs. Subsequently, to verify the above analysis, the R-SFCL-based four-terminal MMC-MTDC with DC bipolar short fault modelling and simulation are presented in the next section. Finally, based on the above analysis and research, the advanced DC bipolar fault control and protection strategies of the R-SFCL-based MMC-MTDC system are discussed to promote further study of coordinated and protection control and the application of R-SFCLs in subsequent engineering applications.","PeriodicalId":242596,"journal":{"name":"2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131739134","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
期刊
2021 Annual Meeting of CSEE Study Committee of HVDC and Power Electronics (HVDC 2021)
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
﹀
mjeditor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1